Issue 41, 2021

A bright, red-emitting water-soluble BODIPY fluorophore as an alternative to the commercial Mito Tracker Red for high-resolution mitochondrial imaging

Abstract

With the emergence and rapid development of super-resolution fluorescence microscopy, monitoring of mitochondrial morphological changes has aroused great interest for exploring the role of mitochondria in the process of cell metabolism. However, in the absence of water-soluble, photostable and low-toxicity fluorescent dyes, ultra-high-resolution mitochondrial imaging is still challenging. Herein, we designed two fluorescent BODIPY dyes, namely Mito-BDP 630 and Mito-BDP 760, for mitochondrial imaging. The results proved that Mito-BDP 760 underwent aggregation-caused quenching (ACQ) in the aqueous matrix owing to its hydrophobicity and was inaccessible to the cells, which restricted its applications in mitochondrial imaging. In stark contrast, water-soluble Mito-BDP 630 readily penetrated cellular and mitochondrial membranes for mitochondrial imaging with high dye densities under wash-free conditions as driven by membrane potential. As a comparison, Mito Tracker Red presented high photobleaching (the fluorescence intensity dropped by nearly 50%) and high phototoxicity after irradiation by a laser for 30 min. However, Mito-BDP 630 possessed excellent biocompatibility, photostability and chemical stability. Furthermore, clear and bright mitochondria distribution in living HeLa cells after incubation with Mito-BDP 630 could be observed by CLSM. Convincingly, the morphology and cristae of mitochondria could be visualized using an ultra-high-resolution microscope. In short, Mito-BDP 630 provided a powerful and convenient tool for monitoring mitochondrial morphologies in living cells. Given the facile synthesis, photobleaching resistance and low phototoxicity of Mito-BDP 630, it is an alternative to the commercial Mito Tracker Red.

Graphical abstract: A bright, red-emitting water-soluble BODIPY fluorophore as an alternative to the commercial Mito Tracker Red for high-resolution mitochondrial imaging

Supplementary files

Article information

Article type
Paper
Submitted
19 יול 2021
Accepted
07 ספט 2021
First published
10 ספט 2021

J. Mater. Chem. B, 2021,9, 8639-8645

A bright, red-emitting water-soluble BODIPY fluorophore as an alternative to the commercial Mito Tracker Red for high-resolution mitochondrial imaging

J. Wang, L. Zhang, L. Gao, J. Chen, T. Zhou, Y. Liu and F. Jiang, J. Mater. Chem. B, 2021, 9, 8639 DOI: 10.1039/D1TB01585K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements