Issue 4, 2021

Determination of gadolinium MRI contrast agents in fresh and oceanic waters of Australia employing micro-solid phase extraction, HILIC-ICP-MS and bandpass mass filtering

Abstract

Gd-based contrast agents (GBCAs) are frequently administered to patients for magnetic resonance imaging to enhance tissue contrasts. After examination, they are excreted and enter surface waters via local wastewater treatment plants' effluents where they lead to anthropogenic Gd anomalies in the environment of metropolitan areas with developed healthcare. This work presents the speciation analysis of GBCAs in water samples from Australia by targeting individual GBCAs in effluent, river and seawater samples obtained from New South Wales (Sydney area), the Northern Territory (Alice Springs) and Victoria (Melbourne area). A method based on hydrophilic interaction liquid chromatography (HILIC) coupled to inductively coupled plasma-mass spectrometry (ICP-MS) provided rapid separation and quantification of four common GBCAs in under three minutes. To improve the sensitivity, ion extraction and transport processes were optimised and the quadrupole mass filter was operated with an increased mass bandpass, decreasing limits of detection to between 18 and 24 ng L−1 for individual GBCAs. This allowed detection of Gd-DOTA, Gd-BT-DO3A and Gd-DTPA-BMA at concentrations of up to 160 ng L−1 in water samples collected from rivers within the proximity of effluents of local wastewater treatment plants. The analysis of GBCAs in oceanic sea water required the development of a novel automated micro-solid phase extraction (μSPE) method for matrix elimination and analyte pre-concentration enabling the detection of Gd-DOTA and Gd-BT-DO3A.

Graphical abstract: Determination of gadolinium MRI contrast agents in fresh and oceanic waters of Australia employing micro-solid phase extraction, HILIC-ICP-MS and bandpass mass filtering

Article information

Article type
Paper
Submitted
30 נוב 2020
Accepted
02 פבר 2021
First published
03 פבר 2021

J. Anal. At. Spectrom., 2021,36, 767-775

Determination of gadolinium MRI contrast agents in fresh and oceanic waters of Australia employing micro-solid phase extraction, HILIC-ICP-MS and bandpass mass filtering

M. Horstmann, R. Gonzalez de Vega, David. P. Bishop, U. Karst, P. A. Doble and D. Clases, J. Anal. At. Spectrom., 2021, 36, 767 DOI: 10.1039/D0JA00493F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements