Jeffrey R.
Bacon†
a,
Owen T.
Butler
b,
Warren R. L.
Cairns
c,
Olga
Cavoura
d,
Jennifer M.
Cook
e,
Christine M.
Davidson
f and
Regina
Mertz-Kraus
g
a59 Arnhall Drive, Westhill, Aberdeenshire, AB32 6TZ, UK. E-mail: bacon-j2@sky.com
bHealth and Safety Executive, Harpur Hill, Buxton, SK17 9JN, UK
cCNR-ISP, Universita Ca’ Foscari, Via Torino 155, 30123 Venezia, Italy
dSchool of Public Health, University of West Attica, Leof Alexandras 196, 115 21 Athens, Greece
eBritish Geological Survey, Keyworth, Nottingham, NG12 5GG, UK
fDepartment of Pure and Applied Chemistry, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL, UK
gInstitut für Geowissenschaften, Johannes Gutenberg-Universität, Becher-Weg 21, 55099 Mainz, Germany
First published on 10th November 2021
In the field of air analysis, highlights within this review period included: a review paper of developments in new personal air samplers for workplace air measurements; a new passive air sampler for Hg0; new filter-based RMs; a new field-deployable carbon analyser for speciation measurements of carbonaceous aerosols and advances in the measurement of RCS using vibrational spectroscopic techniques. The maturity of AAS methods for the analysis of waters was highlighted this year by the lack of significant developments. All the novelty was in sample preparation as reflected in Tables 1 and 2. The tables also reflect the large interest in the use of graphene oxide as a solid phase for preconcentration and the continued use of magnetic nanoparticles. There are now enough methods and application to warrant the inclusion of the analysis of nanoparticles as a separate section rather than as a subsection in speciation. This trend is set to continue as instrumental improvements allow lower size LODs and the determination of lower particle numbers. Notable advances in the analysis of soils and plants included work on the preparation of new RMs as alternatives to NIST soil SRMs that are now in short supply. There was increased interest in the development of miniaturised AES instruments with the potential for field deployment. In the analysis of soil by LIBS, more studies included some form of external validation e.g. comparison with results of an established analytical method, which is most welcome. The availability of well-characterised matrix-matched reference materials continues to be a limitation in the production of high-quality geoanalytical data, particularly when exploring the fine structure of geological materials by microanalytical techniques such as LA-ICP-MS and SIMS. It is heartening to see that many of the researchers working in this area appreciate the importance of making new RMs available to the wider geochemical community. Although the development of portable LIBS systems continues to attract much interest, the current generation of instruments do not appear to be able to match the capabilities of techniques like pXRFS, particularly for the quantification of minor and trace elements in geological settings. Some of the LIBS calibration issues highlighted are reminiscent of those encountered in the early days of pXRFS and should be overcome in time. Many of the reported improvements to in situ measurements of isotope ratios were in support of geochronological studies. Likely future trends include the increased use of imaging in U–Pb geochronology given that LA-ICP-QMS mapping is now capable of acquiring all the required compositional and U–Pb age information at high-spatial resolution.
All the ASU reviews adhere to a number of conventions. An italicised word or phrase close to the beginning of each paragraph highlights the subject area of that individual paragraph. A list of abbreviations used in this review appears at the end. It is a convention of ASUs that information given in the paper being reported on is presented in the past tense whereas the views of the ASU reviewers are presented in the present tense.
A new ambient air sampler12 made it possible to collect sufficient size-segregated ambient air particulate matter in 1 h for improved time-resolved speciation analysis to be carried out. Complementary to this was the development of an agitator sampler for re-suspending and collecting representative road dust samples, thereby enabling both direct (airborne) and indirect (re-suspension) sources of emissions from vehicles to be assessed. A new online integrated PM2.5 measurement system developed for improved chemical mass-closure and source apportionment studies consisted13 of: an aerosol MS for determining molecular species; an XRF system for determining elemental species; an aethalometer for black carbon measurements and a combined nephelometer with beta attenuation for mass measurements. Key to the success of this instrument was the development of a single isokinetic sampler inlet that, under conditions of laminar flow, ensured particles were transported to these various analyser components with a transmission efficiency of close to 100%.
Modification to an air-sampling cassette facilitated14 the rapid workplace analysis of RCS by portable FTIR spectroscopy for timely exposure intervention studies. Particles of <300 nm size can penetrate deep into the lung so use of a new deposition sampler that collects these small particles was proposed15 to provide better estimates of biologically relevant exposures to welding fume than achievable with traditional penetration-based samplers.
A new passive air sampler (PAS) for Hg0 consisted16 of a sulfur-impregnated activated-carbon sorbent contained in the body of a Radello® radial diffusive sampler. It had a sampling uptake rate of 0.07 m3 per day and operated over a useful 1–10000 ng m−3 concentration range so reliable time-weighted exposure averages could be determined in either ambient, residential or occupational air settings. Now commercially available, this sampler was used17 in a study to determine airborne Hg0 concentrations in and around residential settings. The indoor levels (2–10.8 ng m−3) were higher than those (1.8–2.5 ng m−3) measured outdoors so it was concluded that emissions from the households in this study were a net contributor of Hg to the wider atmosphere.
Sampling gases into cylinders or flasks for subsequent compositional and/or isotopic analysis is well established but measurement challenges still exist: these include the need for large air volumes and for dealing with condensable interferences such as water vapour. In a new field-deployable system18 that employed a Nafion™ air drier for sampling CO2, the requisite dry purge-air was usefully provided by initially feeding the spent-exhaust flow from the flask sampling-system through a molecular-sieve cartridge. Sampling requirements for 14CO measurements were reduced19 from 500–1000 L to ca. 90 L at STP by using air compression in conjunction with a small-volume electro-polished stainless-steel cylinder for sample collection. Embedded in this system was a CO scrubber that facilitated the production of a procedural blank for assessing the potential for extraneous 14CO sample contamination that could occur during transportation of samples back to the laboratory. Sources of this contamination could be ingress of air due to leakage or in situ14CO formation due to bombardment of samples with cosmic radiation.
Performance testing of calibration systems for generating Hg gas standards was reported in three publications. A system developed at VSL for production of Hg0 gas standards traceable to the SI was based24 on a diffusion process described in ISO 6145-8. Standards could be prepared with a relative expanded uncertainty of 3% (k = 2) for concentrations between 0.1 and 2.1 μg m−3 and 1.8% for concentrations between 5 and 100 μg m−3. The so-called “bell-jar” calibration, which involves the analysis of a saturated head space of Hg0 vapour kept at a defined temperature, is widely used but a discrepancy of 8% was noted25 between the calibrant gas output from this approach and the output from the new SI-traceable approach. This indicated a problem with the former that is a concern because of its wide use. It was planned to measure Hg0 with a new laser-absorption spectroscopic method (see Section 2.4.5) and to use transfer standards, prepared by dosing sorbent tubes with defined amounts of Hg0, in order to calibrate instruments previously calibrated using the “bell-jar” approach. The output from two generators that produced an oxidised Hg calibrant gas was analysed26 online by ICP-MS. Use of a customised PTFE connector inserted into the ICP-MS torch to ca. 1 cm before the end of the quartz injector improved analyte transfer and so enabled standards of up to 10000 ng m−3 to be measured in <5 min without significant memory effects.
Diesel engine emissions are best mimicked by soot particles with a high EC/TC ratio and a small size. A new prototype particle generator with a novel premixed-flame mode generated27 such particles with an EC/TC ratio of 0.85 and mobility diameter of 50 nm without recourse to a thermal after-treatment process that had previously been required for generation using a diffusion flame. A new laboratory-based facility28 for producing particles that mimic those found in ambient air employed: a generator for production of a carbonaceous particle fraction; a smog chamber to coat these particles with organic compounds and thereby simulate aged particles; a nebuliser to produce an inorganic-salt-particle fraction; and a rotating brush generator to produce a mineral-dust-particle fraction. It is anticipated that this facility will be used for: performance testing of new air sensors; measurement intercomparison studies; and health-related aerosol studies.
In an interlaboratory comparison (ILC) organised29 by JRC Ispra, PM2.5 filter samples that contained elements regulated under the EU air quality directive (As, Cd, Ni and Pb) were sent to laboratories for analysis by either ICP-MS (using EN 14902) or EDXRFS. Whereas there was good agreement amongst the ICP-MS results, it was concluded, unsurprisingly, that EDXRFS analysis was not sufficiently sensitive for the determination of As or Cd at concentrations typically encountered in such particles in ambient air. Reliable EDXRFS Ni and Pb measurements that met data quality objectives prescribed in the EU directive were possible if the concentrations were >25 and >8 ng m−3, respectively. Results from an ILC carried out in 2014 and then repeated in 2019 for the determination of metals (using EN 14385) and Hg (using EN 13211) in stack gas emissions showed30 that participants’ performance had improved but that better consistency and more transparency were still required in the calculation and reporting of LOQs and associated MU values. Blank Hg concentrations in sorbents can sometimes cause inaccuracies. Following a field trial of three different Hg0 passive sampler designs, it was concluded31 that the MerPAS® sampler performed better than the CNR-PAS and IVL-PAS alternatives because it possessed a superior sampling uptake of Hg0 and gave a better S/N.
Measuring PGEs and Re at trace levels in road dust samples remains problematical because of severe isobaric and polyatomic interferences that can arise in ICP-MS analysis. In a new procedure, dust samples were digested33 in inverse aqua regia in a HPA and the PGEs separated from the matrix by CEC for ID-ICP-MS/MS analysis. The use of a mass filter to select only ions of interest in conjunction with the use of ion-reaction chemistry meant that spectral interferences derived from residual elements remaining after clean-up could be avoided. Analysis of IRMM BCR CRM 723 (road dust) gave values that were 71% (Ir), 91% (Os), 100% (Pd), 100% (Pt), 98% (Re), 81% (Rh) and 79% (Ru) of the certified values.
Evaluation of a new Cyrotrap-GC-AED system for the determination of atmospheric trace-organic gas species at pptv levels focused36 on calibration linearities, LODs and the generation of compound-specific response factors for 64 VOCs. The emission lines of Br (163 nm), C (197 nm), I (178 nm), N (174 nm) and S (181 nm) were used. Although quantification with VOC gas standards was preferable, the authors suggested that these new response factors made semi-quantitative analysis to an accuracy of ca. 30–40% possible for those compounds present in a chromatogram but not present in the gas standard. Furthermore, they suggested that this new instrument with its simultaneous CCD detection had potential for detecting other volatile species such as organo-metallic species emitted from volcanoes.
The aerosol chemical speciation monitor (ACSM) is a field-deployable mass spectrometer for measuring the mass and chemical composition of non-refractory sub-μm PM in real-time. In order to validate ACSM measurements, data from laboratory measurements of aerosol PM1 and PM2.5 samples were compared43 with results for samples collected at the same time on filters. Data for particle number and size distributions and black carbon concentrations taken at the same time were also used in the comparison. Systematic deviations between the results for a PM1 fraction obtained using ACSM and those obtained from the offline weighing of filters were attributed to a lower transmission efficiency of the particle-focusing inlet lens for smaller particles than for larger particles. Better correlations were obtained for SO42− (slope 0.96, R2 0.77) and for total particle mass (slope 1.02, R2 0.90). Studies like this are valuable for QA purposes and for identifying potential biases between old and new measuring approaches. Particulate chloride is an important PM component in marine air masses. A revised calibration procedure for improved chloride quantification by ACSM involved44 modifying the standard ion fragmentation data held within the software and adopting a specific calibration for NH4Cl.
The single-particle aerosol-mass-spectrometry of samples from pristine environments with low concentrations of aerosol particles was made45 possible by using a new aerodynamic lens system inlet in conjunction with use of a delayed-ion-extraction protocol. Detection efficiencies of 50% for 230–3240 nm-sized particles and 95% for 350–2000 nm-sized particles were possible for PSL and NaCl test particles. Use of this procedure improved the ion-yield from the ablation, ionisation and extraction processes and resulted in a 7-fold enhancement in signal intensities for cationic species.
Advances in vibrational spectroscopic techniques offer new potential for measuring RCS at low airborne concentrations within occupational settings. Emissions from the cutting and polishing of natural and artificial stones, a workplace activity that can give rise to substantial inhalation exposures if uncontrolled, were measured53 using a new Raman-based procedure. An established XRD-based assay was used in parallel. Results correlated well for both respirable-sized (R2 values of 0.95–0.98, slope of 1.11) and thoracic-sized (R2 values of 0.95–0.98, slope of 1.07) RCS particles tested. The LOD of ca. 0.2 μg was an order of magnitude better than that achievable by XRD analysis. An alternative, QCL-based, IR method involved:54 collection of aerosol on a filter; filter treatment using a low-temperature O2-plasma asher to remove the matrix; redeposition of the RCS as a dried 1 mm2 diameter spot on a secondary filter for direct-on-filter analysis; and measurement of α-quartz at its characteristic 798 cm−1 peak. The LOD was 0.12 μg and results for samples taken from workplaces agreed to within 3–28% with those determined using a reference XRD method.
The reliability of monitoring mercury in stacks is constrained by the availability of accurate and metrologically traceable calibrant Hg0 gas standards which are typically generated on demand using either controlled gas diffusion or permeation processes. Verifying the output from generators is therefore important. Researchers at NIST compared55 results obtained using a previously reported56 high-resolution laser-absorption spectroscopic instrument with those obtained by sampling defined volumes of Hg0 onto sorbent tubes and analysing following desorption using an accurate and precise ID-CV-ICP-MS method.57 The output from a calibrator unit was split so that the two methods could be performed simultaneously. Agreement between the two techniques was within 1–1.8% for Hg0 concentrations of 41–287 μg m−3 thereby confirming the suitability of this new approach as an alternative primary measurement method.
Two interesting papers on the release of trace elements into water have been published. The first looked59 at the release of Ag from two types of PET water bottles doped with Ag: one with porous glass containing Ag3PO4 and the other with Ag NPs. The PET bottles (500 mL) doped with 300 mg kg−1 of Ag (as Ag3PO4 glass) released enough Ag after 10 days to reach a concentration of 2 μg L−1 when stored at 21 °C. This increased to 72 μg L−1 when stored at 43 °C, thereby exceeding the European Food Safety Authority migration limit of 0.05 mg L−1 for 10 day storage at >40 °C. In contrast, the bottles doped with Ag NPs at a higher concentration (400 mg kg−1) released hardly any Ag: the test solutions concentrations were below the ICP-MS LOD (0.1 μg L−1) under all conditions. In an extremely relevant article, given the current Covid-19 pandemic, the leaching of trace elements into water from disposable face masks was measured.60 Seven types of face masks were immersed in 250 mL of deionised water for 24 h. The test solutions were then acidified with 1 mL of 1 M HNO3 and analysed by ICP-MS. It was thought that the Cd, Co, Cu, Pb, Sb and Ti found in some of the solutions came from additives in fibres used to manufacture the masks.
Other significant advances in the SPE of trace elements from water samples are summarised in Table 1 and those in the use of LPE in Table 2.
Analytes | Matrix | Substrate | Coating or modifier | Detector | LOD in μg L−1 (unless stated otherwise) | Validation | Reference |
---|---|---|---|---|---|---|---|
AgI, CdII, and PbII | Drinking, swamp and waste waters | GO–Fe2O3 nanocomposite | 3-Mercaptopropyl trimethoxysilane | FAAS | 3.2 (Cd) to 47.3 (Pb) | Sample spike recovery | 279 |
AsIII | River, tap and waste waters | Magnetic GO nanocomposite | Glucamine | ICP-MS | 0.05 | Sample spike recovery | 280 |
AsV | Natural water | TiO2 nanofibers | Graphitic carbon nitride | ICP-MS | 0.6 ng L−1 | Institute for Reference Materials of SEPA, CRM GSBZ50004-88 (water) | 281 |
AsV | Water | Quartz support | N-Methyl-D-glucamine | TXRFS | 0.05 | Sample spike recovery | 282 |
AsV, SeVI | Water | Cellulose filters | TiO2 | EDXRFS | 0.25 (As) 0.4 (Se) | Sample spike recovery | 283 |
Au | Environmental waters, sediments, soils, coal, ores | Fe3O4 NPs | Poly(1-vinylimidazole) IIP | ICP-MS | 0.002 | Sample spike recovery (water samples); National Research Center for Certified Reference Materials (China) CRM ZBK338 (ore) | 284 |
Be | Waters, alloy samples | Fe3O4 NPs | MIL-53(Fe) type MOF | FAAS | 0.07 | Sample spike recovery | 285 |
Cd | Drinking and river waters, fruit, meat | Magnetic GO | 2-(3-Hydroxy-1-methylbut-2-enylideneamino)pyridine-3-ol (acacapyrH2) | FI-FAAS | 0.06 | Sample spike recovery | 286 |
Cd, Co, Cu, Ni, Pb | Water, food | Cellulose nitrate membrane filter | Quinalizarin | FAAS | 0.1–0.7 | Sample spike recovery; analysis of CRMs | 287 |
Cd, Co, Cu, Ni, Pb, Zn | Spring and sea waters | Cellulose membranes | Mixed GO and carbon CNTs | TXRFS | 0.08 (Cd) −0.21 (Co) | Sample spike recovery; NIST SRM 1640a (trace elements in natural water) and Supelco CRM QC3163 (trace metals 1 in seawater) | 288 |
Cd, Cu, Ni | Estuarine and sea waters | PVC and TBP polymeric membrane | Pyridine-2-acetaldehyde benzoylhydrazone | FAAS | 0.33 (Cu)–0.75 (Ni) | LGC CRM LGC6019 (Thames water); seawater spike recovery | 289 |
Cd, Cu, Pb | Ground, river, and waste waters | GO membrane | Poly-aminophosphonic acid | ICP-AES | 1.1 ng L−1 (all elements) | NIST SRM 1572b (citrus leaves), NIES CRM 10C (rice flour); spike recovery | 290 |
Cd, Co, Cu, Fe, Mo, Ni, Pb, Ti, V | Ground and waste waters | Methacrylate resin | Carboxymethylated polyallylamine | ICP-AES | 4 (Co)–220 (Zn) ng L−1 | SCP Science CRM Enviromat EU-L-1 (wastewater low) | 291 |
Cd, Co, Cu, Mn, Ni, Pb, Zn | Ground, river and sea waters | 3D printed SPE cartridges with Lay-Fomm 40 porous filaments | ICP-MS | 0.3 (Pb) to 6.7 (Zn) ng L−1 | NRCC CRMs CASS-4 (coastal seawater), SLEW-3 (estuarine water), NIST SRMs 1640a (trace elements in natural water) and 1643f (trace elements in water) | 292 | |
Cd, Hg, Pb | Environmental water | Fe3O4 NPs coated with SiO2 | Poly (ethylene glycol dimethacrylate-co-glycidyl methacrylate | ICP-MS | 0.21 (Hg) to 2.9 (Pb) ng L−1 | Chinese GBW CRMs GSB 07-1185-2000 (water quality Cd), GSB 07-1183-2000 (water quality Pb) and GSB 07-3173-2014 (water quality Hg) | 293 |
Cd, Ni | Water | Fe3O4 NPs | Polydopamine IIP | FAAS | 25 (Cd) to 60 (Ni) ng L−1 | NIST SRM 1643e (trace elements in water) | 294 |
Cd, Ni, Pb | Water | Granular activated carbon | Quercetin | FAAS | 0.78 (Cd) to 8.1 (Ni) | NIST SRM 1643e (trace elements in water) | 295 |
CrIII | Drinking, spring and waste waters | Amberlite® CG-120 resin | FAAS | 0.3 | Environment Canada CRM TMDA-70.2 (high level fortified sample for trace elements of Ontario lake water) | 296 | |
CrVI | Water | Magnetic MWCNTs | 3-Aminopropyltrimethoxysilane | FAAS | 3.2 | Spike recovery; comparison with ETAAS results | 297 |
CrVI | Drinking and sea waters | GO | MoS2 | EDXRFS | 0.05 | Supelco CRMs QC1453 (chromium VI in drinking water) and QC3015 (chromium VI in seawater) | 298 |
Hg | Water | Filter paper | Au NPs | Head space portable Zeeman AAS | 0.09 | Spike recovery | 299 |
Hg2+, MeHg+ and EtHg+ | Ground, surface and sea waters; fish | Fe3O4 NPs coated with covalent organic frameworks | 1,2-Ethanedithiol | HPLC-ICP-MS | 0.96 (Hg2+), 0.17 (MeHg+) and 0.47 (EtHg+) | Spike recovery (water); NRCC CRM DORM-4 (fish protein) | 300 |
Hg | Spring and river waters; artificial seawater | Bi2S3 NPs | EDXRFS | 0.06 | Supelco CRM QC3163 (trace metals 1 in seawater) | 301 | |
In | Water | Activated carbon | Sodium dodecyl sulfate | ETAAS | 0.2 ng L−1 | Spike recovery | 302 |
Pb | Drinking, lake and spring waters | Amberlite® CG-120 resin | SQT-FAAS | 0.23 | Environment Canada CRM TMDA-70.2 (high level fortified sample for trace elements in Ontario lake water) | 303 | |
Pb | Contaminated water | MWCNTs | Phenylenediamine | FAAS | 1.5 | NIST SRM 1640a (trace elements in natural water) | 304 |
Ra226 | River water | AG® 50W-X8 resin | ICP-SFMS | 0.46 fg L−1 (10 mBq L−1) | Spike recovery | 305 | |
REE and Y | Sediment pore water | Nobias PA1® resin | ICP-MS | 0.06 (Tm) to 1.47 (Y) pM | Spike recovery and comparison with literature values found in NRCC CRMs CASS-5 (coastal seawater) and NASS-6 (seawater) | 306 | |
Sb | Ground, surface and waste waters | Electrodeposition on microporous glassy carbon electrode | HG-HR-CS-AAS | 0.1 | NIST SRM 1640 (trace elements in natural water) | 307 | |
SbIII and TeIV | Lake, river, and environmental waters | Poly(glycidyl methacrylate–ethylene dimethacrylate) monolithic capillary | Cystamine | ICP-MS | 3.9 (Sb) and 5.9 (Te) ng L−1 | GBW CRMs GSB 07-1376-2001 (water quality antimony) and GBW(E)080548 (tellurium in water) | 308 |
Sr90 | Lake, ground, sea and radioactive waters | Eichrom DGA-B and Sr resins | ICP-MS | 0.47 Bq L−1 (0.09 pg L−1), | Spike recovery and IAEA 2018 proficiency test exercise water | 309 | |
Th, U | Tap, river and lake waters | Fe3O4 NPs | Anoxybacillus flavithermus SO-15 | ICP-AES | 0.014 (Th) and 0.015 (U) | NWRI EC RM, NWTM-15 (fortified lake water) | 310 |
V | Water | Fe3O4 NPs and MWCNTs | 4-(2-Pyridylazo)resorcinol | ICP-MS | 1.5 ng L−1 | NWRI EC CRM TMDA 51.3 (fortified lake water) | 311 |
Analytes | Matrix | Method | Reagents | Detector | LOD in μg L−1 (unless stated otherwise) | Method validation | Reference |
---|---|---|---|---|---|---|---|
AsIII, AsV | Water, soil, sediment | DLLME | APDC (chelating agent) and trihexyl(tetradecyl)phosphonium hexachlorodisprosiate (AsIII) and trihexyl(tetradecyl)phosphonium tetrachloroferrate (AsV) | ETAAS | 17 (AsV) and 20 (AsIII) ng L−1 | Spike recovery | 312 |
AsIII, AsV, MMA, DMA, AB | Drinking, bottled, sparkling and sea waters | DLLME | Sequential extraction with the ionic liquid (IL) 1-octyl-3-methylimidazolium bis((trifluoromethane)sulfonyl)imide (DMA and MMA). | ETAAS | 0.02 (all species) | NRCC CRM NASS-6 (seawater), NIST SRM 1640a (trace elements in natural water) and SPS CRM SPS-SW2 (elements in surface waters) | 313 |
Addition of APDC for AsIII, reduction of AsV to AsIII with sodium thiosulphate. | |||||||
Separate extraction of AB with sodium mercaptoethane sulphonate solution | |||||||
Cd | Water, vegetables, hair | UA-DLLME | 1-Hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate (IL) and 2-(6-methylbenzothiazolylazo)-6-nitrophenol (complexing agent) | FAAS | 0.1 | Environment Canada CRM TMDA-51.3 (fortified water) | 314 |
Cd | Water, urban wastewater, molluscs | UA-LLME | 1,2-Dichloroethane and trichloroethylene (acceptor phase) and 2-(2-bromo-5-pyridylazo)-5(diethylamino)phenol (chelating agent) | FAAS | 0.39 | IRMM CRM BCR-713 (effluent wastewater) and NIST SRM 1566b (oyster tissue) | 315 |
Cd, Co, Cu, Ni, Pb, Zn | Waste and surface waters | LLE | Tetrabutylammonium bromide, (NH4)2SO4 and with 4-(2-pyridylazo)-resorcinol | ICP-AES | 0.012 (Cd) to 0.4 (Zn) | Spike recovery; SPS RMs SPS-SW2 (surface water) and SPS-WW1 (wastewater) | 316 |
Cd, Cu, Ni, Pb | Food, water | Carrier-free coprecipitation | 3-Benzyl-4-p-nitrobenzylidenamino-4,5-dihydro-1,2,4-triazole-5-thiol | FAAS | 0.3–0.8 | 317 | |
Co, Ni | Food, water | UA-DLLME with SFOD | Decanoic acid and DL-menthol (eutectic solvents) and 2-(5-bromo-2-pyridylazo)-5-(diethylamino) phenol (chelating agent) | FAAS | 0.3 (Ni)–0.4 (Co) | 318 | |
CrVI | Water, tea | UA-LLME | Choline chloride and phenylethanol (eutectic solvent) and APDC (complexing agent) | FAAS | 0.8 | Spike recovery | 319 |
Cu | Water, dialysis solution, sweat, urine | Microextraction | THF and decanoic acid (supra molecular solvent) and 1-(2-pyridylazo)-2-naphthol (chelating agent) | FAAS | 7.3 | Environment Canada CRMs TMDA 53.3 (fortified lake water) and TMDA 64.2 (fortified lake water) | 320 |
FeIII | Water, wastewater | LLME | N,N-Dimethyl-n-octylamine (solvent) and 2-(5-Bromo-2-pyridylazo)-5-(diethylamino) phenol (complexing agent) | FAAS | 0.015 | SPS RM SPSWW1 (wastewater) | 321 |
Mn | River, ground, well and tap waters | LLME | Methanol and toluene (extraction solvent) (1-(2-pyridylazo)-2-naphthol (ligand) | ICP-MS | 0.1 ng L−1 | Spike recovery | 322 |
Pb | Tap, lake and river waters; salted peanuts, chickpeas, roasted yellow corn, pistachios, almonds | LLME | Alpha-benzoin oxime and iron(III) chloride dissolved in phenol | FAAS | 8 ng L−1 | Environment Canada CRMs TMDA 64.2 (lake Ontario water), TMDA 53.3 (fortified lake water), and NACIS CRM NCSDC-73349 (trace elements in bush branches and leaves) | 323 |
Pd | Stream, tap and sea waters | LLME | N-(3-Chloro-4-fluorophenyl)-N-phenylthiourea | FAAS | 2.3 | Spike recovery | 324 |
SbIII | Tap, dam, mineral, wetland, underground, rain and river waters | DLLME | Trihexyl(tetradecyl)phosphonium tetrachloroferrate (magnetic ionic liquid extractant) and ammonium diethyldithiophosphate (complexing agent) | ETAAS | 0.02 | Spike recovery | 325 |
Se and Te | Soils and sediments; sea, river, underground and tap waters | FI-LLME | 1-Octyl-3-methylimidazolium chloride and KPF6 (ionic liquid), APDC (chelating agent) | HG-AFS | 1.8 (Te) and 2.6 (Se) ng L−1 | Spike recovery; IRMM CRM BCR 402 (white clover) | 146 |
Th | Wastewater; phosphate rocks | CPE | 2-(2,4-Dihydroxyphenyl)-3,5,7-trihydroxychromen-4-one (complexing agent) and Triton X-114 and KI (cloud point agents) | ICP-AES | 0.11 | Spike recovery | 326 |
The wider availability of ICP-MS/MS has made the speciation of organo-halogen or halogen-tagged molecules more accessible. For instance, a mix of chlorinated and brominated acetic acids was successfully separated65 on a mid-bore C18 HPLC column and detected by HPLC-MS/MS. With an injection volume of 50 μL, the LODs of 0.8 and 1.4 μg L−1 for Br and Cl, respectively, were well below the US EPA maximum contaminant level of 60 μg L−1 for these compounds. The method was validated by analysis of spiked samples and the Sigma Aldrich RM EPA 552.2 (haloacetic acids mix). Mono- and di-iodoacetic acids were separated66 by AEC and ICP-MS detection. No preconcentration was necessary. The results compared favourably with those from 5 control laboratories using Chinese standard methods for the analysis of raw waters with high I concentrations after disinfection with Cl and UV irradiation. The LODs of 0.06 and 0.04 μg L−1 for the mono- and di-iodoacetic acids, respectively, were comparable to those obtained by the control laboratories which used a sample preconcentration step before analysis.
Although not strictly atomic spectrometry, the determination of Fe2+by ESI-MS is of interest.67 Complexation with 1,10-phenanthroline resulted in peaks such as that at m/z 208 ([Fe (phen)2]2+) which could be used to determine Fe2+ concentrations in river waters. Results compared well with those obtained using a standard colorimetric method. Of the total Fe present in Japanese rivers, 40% was present as Fe2+. Unfortunately, the authors did not report an LOD for comparison with current colorimetric and chemiluminescence methods.
The determination of Gd-based contrast agents in waters remains of interest because these agents can enter the environment from WWTPs. Gadolinium-containing compounds in seawater were successfully separated68 from the matrix on micro SPE cartridges packed with graphitic carbon for analysis by HILIC-ICP-MS. A four-fold preconcentration factor was obtained by using a sample volume of 1 mL and an elution volume of 0.25 mL. It was possible to determine Gadoterate Meglumine (Gd-DOTA) and Gadobutrol (Gd-BT-DO3A) at concentrations of 180 and 140 ng L−1, respectively, in Australian coastal seawater. As HILIC chromatography can be considered similar to normal-phase chromatography, it is not generally considered to be compatible with ICP-MS analysis. To overcome this problem, researchers developed69 an aqueous mobile phase capable of separating the main 6 commercially available Gd-based contrast agents on a HILIC column before ICP-MS detection. The LODs were between 3.7 ng L−1 (Magnevist® Gd-DTPA) and 22 ng L−1 (ProHance® Gd-HP-DO3A) and so were sufficient for identifying these compounds in waters near the outfall from a WWTP. The method also allowed the preliminary quantification of unknown Gd compounds (suspected transformation products) in river water.
To widen the applicability of mercury speciation methods in water, a SPE method was adapted70 to preconcentrate Hg and Pb species simultaneously for detection by HPLC-ICP-MS. A C18 SPE cartridge conditioned with 2-mercaptoethanol was used to separate species from coexisting ions in water with preconcentration factors ranging from 459 for Pb2+ to 2400 for Hg2+ for 10 mL samples. The LODs were 0.001 and 0.011 ng L−1 for Hg and Pb, respectively, in freshwater samples. The results were validated by analysis of the Chinese RMs GBW08603 (mercury in water) and GBW08601 (lead in water). A two-step CPE method was developed71 to prevent peak overlap after extraction and thereby to improve the LOD of an HPLC-CV-AFS method for mercury species in water and soils. In the first step, the mercury species were preconcentrated into Triton™ X-114 micelles as DDTC chelates. To make the extract compatible with HPLC, this solution was then back extracted into a 0.1% m/v L-cysteine solution. The LOD of 4 ng L−1 for inorganic mercury and 16 ng L−1 for methylmercury were probably sufficient for the quantification of Hg species in soil samples but insufficient for the analysis of uncontaminated waters.
As chromatographic methods for elemental speciation mature, focus is shifting to preconcentration methods for elemental species. Methods developed for one specific oxidation state are included in Tables 1 and 2 whereas methods for one or more organometallic species are included in this section. Graphene oxide bound to silica NPs was modified72 with sodium dodecyl benzene sulfonate to preconcentrate tetramethyl and tetraethyl lead from river waters. Enrichment factors of >1300 were obtained for both species in 10 mL samples. By using fairly standard HPLC conditions (buffered ion pairing agents) and ICP-MS detection, the method LODs were 0.018 for (tetramethyl lead) and 0.023 (tetraethyl lead) ng L−1. Cytostatic Pt compounds used in chemotherapy were isolated73 from a WWTP effluent using strong anion exchange cartridges. The ionic forms of Pt were adsorbed on the cartridge at pH 3 and then eluted at high pH with 5–10% v/v NH3 solutions. Despite extensive optimisation, the adsorption and desorption efficiencies were quite low (44–68%). No HPLC-ICP-MS analysis was undertaken so the actual species being preconcentrated was not confirmed. The extensive body of literature on the separation and retention of this class of compounds on ion-pair-modified C18 silica phases contains the information needed for improving this method.
The performance of single particle ICP-MS continues to be improved. A total consumption nebuliser was proposed77 as a means to avoid particle loss during nebulisation. As all the sample was nebulised at a liquid flow rate of 8 μL min−1, there was no need for determining the transport and nebulisation efficiencies. Under these conditions, the size distributions of gold, platinum and silver NPs in known standards were determined successfully. The method was then applied to the determination of gold NPs in surface waters after dissolved-standard calibration to determine the NPs’ average diameter. In the ICP-SFMS determination of CeO2 NPs in Canadian waterways, the size LOD was improved78 to <4 nm by using a 50 μs dwell time and gold and silver NPs as size RMs. The NP number and size were then successfully determined in samples of urban rainwater and river water. Up to 36% of the Ce-containing NPs in Montreal rain were engineered NPs. As mentioned in previous ASUs, sizing can be improved by eliminating the dissolved fraction signal. Cloud point extraction of dissolved Ag has once again been confirmed79 as a suitable method for this task. By removing the dissolved Ag from the sample and then preconcentrating the silver NPs present, the size LOD was reduced from 20 to 4.5 nm.
The coupling of asymmetric field-flow-fractionation with ICP-MS continues to be a reference method for the sizing of particles within complex matrices. In a study of coated platinum-NPs in water samples, quantitative membrane recoveries for a 30 min run time allowed80 5, 30 and 50 nm NPs added to natural and artificial (humic acid added) surface water samples to be separated. As found in previous studies, complexation by OM in the water was a critical factor.
The concentrations and metal loads of nanoplastics in the environment are becoming of increasing concern. A method to detect microplastics by ICP-MS involved81 functionalising polystyrene microspheres with gold NPs and detection with sp-ICP-MS. The functionalisation with gold NPs made it possible to count individual particles. The quantification limit was 8.4 × 105 particles per L and the response was linear up to 3.5 × 108 particles per L for particles of up to 1 μm diameter. The size LOD was 135 nm. The LA-ICP-MS depth profiling and mapping of marine plastics was used82 to discriminate between surface adsorbed metals (As, Cd, Cu, Fe, Sb, Sn, Pb, U and Zn) and additives (Cu, Pb or Sb) in the bulk polymer. Mapping of the plastics made it possible to estimate diffusion of the metals from the surface to the subsurface during weathering.
The use of heated spray chambers was investigated84 to improve the sensitivity of ICP-AES instruments at low flow-rates. An instrument operating with different heated spray chambers and nebulisers at sample flow rates between 50–75 μL min−1 had a sensitivity similar to that obtained using a normal cyclonic spray chamber with a nebuliser operating at 1 mL min−1.
The development of low-power discharges for water analysis continues to be of interest and useful LODs are now being achieved. A solution cathode-glow-discharge was used85 as an excitation source for the determination of Ga and In in water samples. Whereas few interferences were present in the determination of In, even when matrix components were present in a 20-fold excess over the analyte concentration, the determination of Ga suffered severely from interferences. As a consequence, the LOD for Ga (0.1 μg L−1) was much higher than that for In (0.016 μg L−1). The same type of excitation source was successfully coupled86 with HG to determine Sb in water samples. Standard HG conditions for the generation of stibine gas gave an LOD of 0.36 μg L−1, good spike recoveries and results for real samples comparable with those obtained by ICP-MS. The use of low power means instruments can be made portable. An instrument with a DBD to generate a microplasma was used87 in the field to determine As and Sb in environmental water samples. The solid reagent sulfamic acid was used instead of HCl when possible in order to reduce liquid waste. The LODs of 0.5 and 0.2 μg L−1 for As and Sb, respectively, were impressive for an instrument that weighed only 15 kg in total and operated at <60 W total power consumption.
The chemical vapour generation of CrVI was enhanced90 by the addition of sodium diethylaminodithioformate to the reaction mix of KBH4 and HCl. The total Cr concentration was determined after oxidation of the sample with KMnO4 so the CrIII concentration could be calculated. The chemical VG efficiency of 28% resulted in an LOD of 0.2 μg L−1 for CrVI when using ICP-MS detection. The method was validated by spike recovery from tap water and analysis of the Chinese CRM GEW(E)080197.
A gold trap typically employed in the determination of Hg was used91 for the preconcentration of Se after HG. The AAS LOD was improved from 0.23 to 0.013 μg L−1 by trapping at of 450 °C for 300 s and desorbing at 970 °C. This device could not be used with ICP-MS because of losses of volatile Se species by condensation onto the cold tube walls between the amalgamation unit and the plasma torch. In an offline preconcentration procedure,92 H2Se generated by direct addition of the reagents to the sample was trapped in an aqueous ammonium solution that was then analysed directly by AAS. Recoveries of spikes from tap water samples were 99 ± 3% and the LOD was 1.3 μg L−1.
The dielectric barrier discharge, an up-and-coming addition to VG systems, was successfully coupled93 with ICP-MS for the detection of PGEs in river, lake and rain waters. The sample was nebulised into the DBD in the presence of formic acid to improve the generation of volatile PGE species. The LOD was reduced 10-fold when compared to normal nebulised sample introduction and the spike recoveries from the water matrices ranged from 80% (Pd in rainwater) to 110% (Pt in lake water). The typical use of DBDs in AAS and AFS is as atomisers and atom traps for hydrides, as exemplified94 by the determination of Sb in bottled water. An LOD of 5 ng L−1 was achieved with a 50 s accumulation time followed by atomisation and AFS detection. The instrumental response was linear up to 50 μg L−1. A seven-fold improvement in sensitivity over that achievable by standard HG-AFS was obtained and the recoveries of spikes from bottled tap water samples were quantitative.
Sample stabilisation before the determination of mercury by ICP-MS is always important. A mixture of thiourea and HCl stabilised96 Hg in humic-acid-rich waters before direct analysis without the need for further sample preparation. The LOD of 0.4 ng L−1 indicated that the researchers had managed to maintain low Hg blank levels. The method was validated by analysis of the IRMM CRM ERM®-CA615 (groundwater) and by recoveries of spikes from waters with artificially enriched humic-acid contents.
Matrix separation remains an important strategy for ICP-MS analysis of samples such as seawater that have challenging matrices. An online desalination device removed97 Ca, Mg and Na from seawater samples during analysis. A helical coil packed with an element-specific ion-imprinted-polymer removed the matrix ions but did not retain the analytes (As, Cd, Cu, Mn, Ni, Pb, Sb, Tl). The desalination device was effective for at least 9 h. Removal of the matrix improved the LODs for all analytes. Trueness and repeatability of the method were determined to be <3 and <5%, respectively, by analysis of the NRCC CRM CASS-5 (nearshore seawater) during the analytical run. Because analyte preconcentration from WWTP effluents was impeded by the presence of EDTA in samples, it was destroyed98 by digestion with a mix of HNO3 and H2O2 prior to preconcentration of Fe, Cu and REEs on a chelating resin. The method was validated against the JSAC CRM JSAC 0302-3c (river water) with ICP-MS detection.
It has been demonstrated99 through analysis of the NMIJ CRM 7202-c (river water) that Ne can be used successfully as a collision gas for ICP-MS analysis of river water. Helium was considered100 the collision gas of choice for the quantification of REEs in fresh and slightly saline waters and digested sediments but the interference of Ba on Eu and the difficulties in determining Sc remained. The method was validated by the recovery of spikes from 5 commercial mineral waters and by the analysis of the NRCC CRMs SLRS-6 (river water), SLEW-3 (estuarine water) and AQUA-1 (drinking water). Oxygen was used101 as reaction gas in the ICP-MS/MS determination of REEs in order to form REE monoxide ions and thereby displace the analyte peaks from those of the interferences. The LOD for the direct analysis of waters were from 0.004 (Er) to 0.26 (Nd) ng L−1. The method was validated against the NRCC CRM SLRS-4 (river water). The REE concentrations in various Japanese lake and river water samples were determined.
Addition of methane to the plasma improved102 the detection limit for P in water as determined by ICP-SFMS. The addition of a flow of 6 mL min−1 resulted in a 3-fold sensitivity increase and a LOD of 7 ng L−1. That methane did not generate any spectral interferences was verified by scans in medium resolution mode. The method, validated by analysis of the Chinese RM GBW(E)081215 (phosphate in plant root water), was considered sensitive enough to determine P in Arctic glacial meltwaters and lake, river, rain and sea waters.
The determination of226Ra was simplified103 by replacing the standard R = 10000 medium resolution slit of an ICP-SFMS instrument with a R = 2000 slit to ensure spectral peak separation from known interferents whilst maintaining a flat topped peak for good isotope ratio determinations. As the concentrations in seawater were expected to be between 0.03 and 0.1 fg g−1, the 226Ra was initially preconcentrated from 1 L of seawater by coprecipitation with MnO2 and then isolated using a 2 column clean-up procedure (strong CEC followed by extraction chromatography). The extraction efficiency was 90–99% and the method LOD 0.033 fg g−1. The results for samples taken at one of the cross reference stations used in the GEOTRACES cruises compared well with those obtained by alternative methods.
The isotope ratios of Sr (87Sr/86Sr and δ88/86Sr) in sediment pore waters were determined104 by MC-ICP-MS following a single miniaturised extraction protocol that used 30 μL of Sr Spec resin. The matrix was removed with three 1 mL aliquots of 3 M HNO3 and the Sr by three volumes (0.25, 1.25 and 1.5 mL) of deionised water. Indicative values measured for the NIST SRM 1640a (trace elements in natural water) were 87Sr/86Sr = 0.708790 ± 0.000062 and δ88/86Sr = 0.07 ± 0.10‰ (2SD, n = 6). All of the various analytical methods compared105 for the MC-ICP-MS determination of Pb isotopes in seawater involved Pb separation by either SPE with the Nobias Chelate PA-1® resin or coprecipitation with Mg(OH)2. Mass bias was corrected using either a Pb double-spike or external normalisation to Tl. For the analysis of seawater with Pb concentrations of 1–7 ng, all the ICP-MS methods gave results comparable to those obtained by TIMS analysis but with a higher sample throughput. The use of resin extraction gave the highest analytical throughput and was most suitable for high-silicate waters but the low cost of precipitation made it an attractive alternative for waters with low concentrations of silicates.
The oxidation state speciation of Fe using LIBS detection was achieved108 by preferentially trapping Fe2+ and Fe3+ on an iminodiacetic acid functional group resin at different pH values. After species-specific trapping, the resin was ground and tabletted before LIBS measurement of the Fe content. The LODs were 0.120 (Fe2+) and 0.142 (Fe3+) mg L−1. The method was validated by spike recovery and comparison with ICP-AES results.
A 111Cd–113Cd double-spike ICP-MS procedure was used114 to determine Cd isotope ratios in 34 RMs that covered a wide range of environmental matrices. The method precision of better than ± 0.074‰ (2SD) was determined from analysis of RMs using an optimum mixing ratio of 111Cdspike/112Cdsample of 2.0. The δ114/110Cd values of −0.001 to +0.287‰ for rock and −0.806 to +0.142‰ for biological samples provided a useful database for monitoring studies. The Cd mass fractions and isotope compositions in NIST SRMs 1566b (oyster tissue), 1573a (tomato leaves) and 1575a (pine needles), IRMM CRM BCR 482 (lichen) and ERM CE278k (mussel tissue) were determined115 by TIMS using a 116Cd–106Cd double-spike. Based on analysis of NIST SRM 3108 (Cd standard solution), the precision of the procedure was high at δ114/110Cd = −0.005 ± 0.029‰ (2SD, n = 47). Variations in δ114/110Cd ranged from −0.52‰ ± 0.03 (2SD, n = 5) for mussel to +0.24‰ ± 0.04 (2SD, n = 6) for pine needles. This study highlighted the potential for using natural mass-dependent Cd fractionation in biogeochemical studies.
Isotopic ratios for Mg were determined116 following digestion in HNO3 + H2O2 for a range of RMs: IRMM CRMs BCR-383 (green beans) and BCR-380R (whole milk); NIST SRM 1577c (bovine liver); ERM-CE464 (tuna fish); and NRCC CRMs DORM-2 and DORM-4 (fish protein) and TORT-3 (lobster hepatopancreas). The separation of Mg from the sample matrices involved a three-column procedure: the first column contained AG1-X8 anion-exchange resin for removal of Fe; the second contained AG50W-X12 cation-exchange resin, which was eluted with 1 M HCl for removal of Ca, Na, P and S; and the third was a another AG50W-X12 column, which was eluted with 0.4 M HCl for removal of other matrix elements, in particular K. The isotopic analysis was performed in two laboratories on three MC-ICP-MS instruments. The measured δ26Mg values for three USGS basalt RMs and IAPSO (standard sea water) were not significantly different from published values. Measured relative to the value for the RM DSM-3 (nitrate solution), δ26Mg ranged from 0.52‰ ± 0.29 (2SD, n = 7) for the bovine liver to −1.45‰ ± 0.2 (2SD, n = 5) for the tuna fish with a precision of 0.03‰ (2SD, n = 85). Accurate Mg isotopic determinations would be of value not only in environmental but also in human health studies as variations have recently been reported in patients with type 1 diabetes.
A protoype IR sample digestor developed118 as a simple and inexpensive means for digesting soils consisted of a wooden box that housed two commercial IR lamps and had a metal lid with 18 holes to accommodate 50 mL PTFE microwave-digestion vessels. For digestion, HNO3 (2 mL) was added to the sample (150 mg) and heated to dryness, followed by addition of H2O2 (2 mL), also heated to dryness. The total heating time was 30 min. Triplicate MIP-AES determinations of Ca, Cd, Cu, Fe, K, Mg, Mn, P, Pb and Zn in NIST SRM 2711 (Montana soil) and EMBRAPA RM Agro E2002a (tropical soil) gave extraction efficiencies of 80% (Mg) to 99% (Pb) and of 83% (Ca) to 99% (Mg), respectively.
Various digestion methods for the determination of Cd isotope ratios in a range of soil and plant materials were studied.119 High pressure bomb digestion at 195 °C for 72 h with a 1 + 3 mixture of HNO3 and HF did not lead to Cd loss and δ114/110Cd values for the four soil and two plant RMs tested gave reproducible results within reported values. On the other hand, dry ashing, performed at 550 °C for between 12 and 24 h with 25–700 mg sample, followed by heating at 120 °C for 24 h with a 1 + 3 v/v mixture of HNO3 and HF, resulted in Cd loss and perturbation of Cd isotope ratios to varying degrees in all sample types. That dry ashing was unsuitable for Cd isotope ratio measurements was demonstrated by the 2.69‰ deviation in δ114/110Cd obtained for NIST SRM 1570a (spinach leaves). The values of −0.07 ± 0.09‰ and 0.26 ± 0.05‰ for δ114/110Cd in NIST SRM 1573a (tomato leaves) and NRCCRM RM GSD-30 (drainage sediment), respectively, were the first that had been reported.
The drive for improved reagents for extraction led120 to the synthesis of three stable ILs derived from substituted benzothiophenes. The relatively time-consuming process involved thiophene metalation, performed at −30 °C, followed by α substitution with an ethyl, butyl or dodecyl group to produce the 2-alkylbenzothiophene. This was reacted with silver tetrafluoroborate (0.44 mM) and methyl iodide (2.8 mM) for 12 h and cooled to −18 °C overnight to obtain the final salt. The products were characterised spectroscopically and by DSC. The 1,2-dimethylbenzo[b]thiophenium tetrafluoroborate salt (10 mM) for the MAE (250 W, 120 °C) of metals in spiked estuarine sediments (pH = 2) extracted the same amounts of Cd, Cu, Cr, Ni, Pb and Zn (paired t-test, tcalc. < tcrit.) as the first two fractions of the BCR protocol together. However, the reaction time of only 30 s was much shorter than the 32 h required for the BCR procedure. Based on simulations of solvent efficiency, nine natural DESs were prepared121 and water content, reaction time and temperature optimised for the extraction of Cu, Mn, Mo and Zn from powdered barley grass (Hordeum vulgare L.). Metal concentrations were determined by ICP-MS/MS. Maximum extraction efficiency was obtained when the water content was above 50% for all solvents. Optimum extraction durations and temperatures were DES-specific. The Cu, Mn and Mo contents determined in ERM CD281 (rye grass) were accurate but there was an overestimation of the Zn content that was attributed to contamination. A methanol-based solvent-extraction-procedure was proposed122 to overcome the problem of changing particle size distribution observed in enzymatic extraction protocols for NP analysis. It involved sonification of homogenised NP-treated leaves, addition of 50% v/v MeOH + deionised water and shaking of the resultant solution (150 rpm, 1 h). Tween 80® (1% v/v) was added for NP stabilisation prior to filtration and dilution for sp-ICP-MS or sp-ICP-TOFMS analysis. The method was tested on corn, lettuce and kale samples spiked with Au, CuO and ZnO NPs. The total metal recoveries of 70–100% were influenced by both the NP and the leaf type. The procedure has potential for the monitoring of nanoparticulate agrichemicals.
A HNO3-based leaching method for the determination of radionuclides of Am and Pu in soils and sediments employed123 several clean-up steps to remove interfering elements and to reduce matrix effects. The method combined several traditional steps: sample ashing; HNO3 leaching; coprecipitation with Fe(OH)3 for the removal of alkali and alkaline metals; a two-stage chromatographic separation, firstly with UTEVA and DGA resins for separation of Am and Pu and removal of interfering elements (Bi, Hf, Hg, Pb, Pt, Th, Tl and U) and then with TEVA® resins for further purification; and ICP-SFMS quantification. Concentrations of Am and Pu measured in IAEA CRMs 447 (moss-soil), 384 (Fangataufa lagoon sediment) and 385 (Irish Sea sediment) and NIST SRM 4357 (ocean sediment) ranged from 83.6 ± 8.0% to 88.4 ± 2.4% and 70.6 ± 6.4% to 91.1 ± 0.5% of the certified values, the LODs for 2 g samples of 0.039 mBq g−1 (0.31 fg g−1), 0.94 μBq g−1 (0.41 fg g−1), 2.33 μBq g−1 (0.28 fg g−1) and 1.35 mBq g−1 (0.35 fg g−1) for 241Am, 239Pu, 240Pu and 241Pu, respectively, made the method suitable for simultaneous determination of ultratrace quantities of the nuclides from global fallout or nuclear accidents.
A novel online protocol for sequential extraction from small samples such as fine dusts was based32 on the BCR and Tessier schemes but with a more relevant reduced sample-size of 5 mg. Traditional solvents were diluted with 3% HNO3 to enable direct online introduction of extracts for ICP-SFMS analysis. Optimal pump-flow-rate was 0.3 mL min−1 with a transfer-line diameter of 0.25 mm. Mobility patterns were determined in the multi-element (Al, Ba, Ca, Cd Co, Cr, Cu, K, Mg, Mn, Na, Ni, Pb, Rb, Sr, V and Zn) characterisation of soils, coals and mine- and road-dusts. The total mass recovery was 72% of that obtained by conventional offline extraction because lower extractant concentrations and shorter extraction times were used. To determine the physico-chemical partitioning of PTEs in airborne PM, Sagagi et al.124 developed two non-specific flow-through sequential extraction procedures with chemometric identification of substrates and element distribution (CISED) methodology. One method was based on reduction of sample requirement (2 g of sample and 10 mL of extractant) for a standard CISED extraction to 0.1 g of sample and 3 mL extractant. The other method employed an in-line quasi-flow-through system in which the sample was supported on a TX40 filter in a 47 mm polycarbonate filter holder. When applied to IRMM BCR CRM 701 (lake sediment), the extractions gave recoveries comparable to those of the well-established BCR extraction steps 1–3. The CISED data processing identified seven distinct geochemical components including carbonates, oxyhydroxides and species dominated by Fe and Si. The flow-through method is potentially useful for identification of the geochemical components of urban air pollution and the assessment of associated health risks.
In the element-specific extraction of Hg from surface sediments, de Jesus et al.125 demonstrated that Hg could be extracted without digestion by using dithiothreitol as a chelating agent. The relatively simple procedure involved sonication (250 mg sample, 30 min) with dithiothreitol solution (4 mL, 0.1 M, pH 9) and CV-AAS analysis. Method LODs and LOQs were 6 and 19 ng g−1, respectively. Results obtained for analysis of NRCC marine sediment CRMs MESS-3 and PACS-2 were 0.112 ± 0.014 and 3.11 ± 0.36 mg kg−1 (certified values 0.091 ± 0.009 and 3.04 ± 0.20 mg kg−1). A method for the microcolumn-based leaching of bioaccessible Pb for online ICP-AES analysis allowed126 near-real-time monitoring of Finnish shooting-range soils under various physicochemical conditions. The custom-made 5 × 0.8 cm column consisted of a Teflon cylinder with three cotton buds positioned at the column inlet and outlet for eluate filtration. The sample mass of 2.5 g, larger than that usually packed in microcolumns, gave more representative sampling. The column was positioned upright and an eluent flow rate of 0.3 mL min−1 used to deliver eluate to the ICP-AES instrument through polyurethane tubing. A range of solutions was tested. For soil samples containing ca. 500 mg kg−1 Pb, extractant efficiency was 55% for 0.11 M acetic acid, 58% for 1 M MgCl2, 61% for 0.1 M NH2OH·HCl, 93% for 0.1 M citric acid and 96% for 0.1 M HCl. Analysis time was under 5 h. A slurry sampling procedure followed by HR-CS-ETAAS analysis, proposed for the determination of Yb in road dust samples, involved127 ultrasonic homogenisation for 34 min with 0.24 M HNO3. The analysis of NIST SRM 2586 (trace elements in soil containing lead from paint), NCS DC 73301 (rock) and CCRMP TILL-1 (geochemical soil) using pyrolysis and atomisation temperatures of 1200 °C and 2700 °C, respectively, gave accuracies of 99 ± 4 to 104 ± 2%.
Other methods for the analysis of soils, plants or related materials, or those developed for other sample matrices that used soil or plant CRMs for validation, are summarised in Table 3 (liquid-phase extraction methods) and 4 (solid-phase extraction methods).
Analytes | Sample matrix | Method | Reagent(s) | Detector | LOD (μg L−1, unless otherwise stated) | RMs or other validation | Reference |
---|---|---|---|---|---|---|---|
Ag | Sediment, water | CPE | n-Octanol, Triton X-100 (cloud point reagents), rhodanine chelating agent | FAAS | 0.18 | NRCCRM GBW 07301 (stream sediment), GBW 07311 (stream sediment); GBW 07312 (stream sediment) | 327 |
AsIII, AsV | Sediment, soil, water | MIL LLME | For AsIII, APDC chelating agent and trihexyl(tetradecyl)phosphonium hexachlorodisprosiate MIL extraction solvent; For AsV trihexyl(tetradecyl)phosphonium tetrachloroferrate and magnetic rod separation | ETAAS | 0.13 ng g−1, 0.11 ng g−1, 17 ng L−1. For AsIII; 0.14 ng g−1, 0.13 ng g−1, 20 ng L−1 for AsV in sediment, soil and water respectively. | Spike recovery | 312 |
CrVI | Organic fertilisers | CPE | 2% m/v NaCl, 0.3% v/v Triton X-100, and 0.05% (m/v) 1,5 diphenylcarbazide | FAAS or UV-Vis | 0.55 μg g−1 for FAAS, 0.41 μg g−1 for UV-Vis | NIST SRMs 2701, (hexavalent chromium in contaminated soil), and 695 (trace elements in multi-nutrient fertilizer), spike recovery | 328 |
iHg, MeHg | Soil, water | Dual CPE | Sodium DDTC and Triton X-114 followed by displacement into L-Cys | HPLC-HG-AFS | 0.004 for iHg and 0.016 for MeHg | Spike recovery | 71 |
Mn | Soil | Switchable solvent LLME | N,N-Dimethylbenzylamine with deionised water switchable solvent; ((E)-2,4-dibromo-6-(((3-hydroxyphenyl)imino)methyl)phenol complexing agent | SQT FAAS | 0.71 | Spike recovery | 329 |
Pd | Catalytic converter, road dust, water (tap, sea), wastewater | LLME | DES based on phenyl salicylate and menthol | ETAAS | 0.03 | Spike recovery | 330 |
Se | Food, soil, water | VAME | APDC complexation,1-butyl-3-methylimidazolium hexafluorophosphate IL, Triton X-114 | ETAAS | 0.07 | NRCCRM GBW 07309 (stream sediment); NCS ZC73032 (celery) | 331 |
Analytes | Matrix | Substrate | Substrate coating | Detector | LOD (μg L−1) | RMs or other validation | Reference |
---|---|---|---|---|---|---|---|
AsIII, As | Rice | Tetra-n-butylammonium bromide | HG-AAS | 0.01 μg g−1 | IRMM 804 (rice flour) | 332 | |
Cd, Co, Cu, Ni, Zn | Parsley, radish (black), quince, soil, water | Fe3O4 MNP | Polythiophene | Microsample injection system- FAAS | 1.1 for Cd, 3.2 for Co, 1.4 for Cu, 9.6 for Ni, 1.2 for Zn | IRMM BCR 715 (industrial effluent waste water); SPS WW2 Batch 114 (wastewater); NCS DC 78302 (Tibet soil); LGC7162 (strawberry leaves) | 333 |
Cd, Zn | Soil, water | Chemically-modified activated carbon with L-arginine | FAAS | 1.6 for Cd, 2.4 for Zn | Spike recovery | 334 | |
Co, Cu | Soil, vegetable, water | Amberlite® XAD-4 resin | Tricholoma populinum fungal biosorbent | ICP-AES | 0.019 for Co, 0.034 for Cu | CNRC DORM-2 (dogfish muscle); NCS ZC73014 (powdered tea); NWRI NWTM-15 (fortified water); NIST SRM 1643e (trace elements in water) | 335 |
Cu, Pb | Herbs | Magnetic MWCNTs | 1-(2-Pyridylazo)2-naphthol | FAAS | 18.9 for Cu, 16.6 for Pb | SPS WW2 (wastewater); NCS DC73349 (bush branches and leaves) | 336 |
Interest in the use of HR-CS-ETAAS and its variant HR-CS-ETMAS continued. An optimised method for the quantification of Yb in road dust involved127 sonication of the sample in 0.24 M HNO3 for 34 min, injection of 20 μL of slurry into a graphite furnace pre-conditioned with 250 μg of W permanent chemical modifier, pyrolysis at 1200 °C and atomisation at 2700 °C. The LOD was 22 ng g−1 and results for analyses of three CRMs were not significantly different from the certified values according to a Student’s t-test at 95% CI. Germanium could be measured135 directly in 0.1–0.2 mg solid plant and soil samples by using a mixed-matrix modifier (0.1% w/w Mg(NO3)2 + 0.2% w/w Pd(NO3)2 + 0.1% Triton X-100) and pyrolysis and atomisation temperatures of 1500 and 2550 °C, respectively. The LOD of 0.5 mg kg−1 made it possible to quantify Ge in tissue samples from a range of plants but some discrepancies were noted with respect to results obtained by ICP-MS following acid digestion. A method for quantification of P in solid samples based on the PO molecular species involved136 pyrolysis at 1500 °C and vaporisation at 2200 °C. The preferred chemical modifier was 10 μg of Au which promoted conversion of P to PO. The method was validated by the analysis of NIST SRMs 1547 (peach leaves), 1573a (tomato leaves) and 1570a (spinach leaves) which contain 1371 ± 82, 2161 ± 28 and 5187 ± 67 mg kg−1 of P, respectively.
Aerosol dilution was demonstrated139 to improve the tolerance of MIP-AES to samples with high total-dissolved-solids content. The signal suppression that occurred at NaCl concentrations > 0.9 g L−1 when using conventional nebulisation was less severe with aerosol dilution: indeed, the emission intensity for some lines was greater in solutions containing 5 g L−1 NaCl than in those containing 0.1 g L−1. A PVG-SPME-TD manifold was optimised140 for the determination of Hg by MIP-AES. Sample solution containing 5% v/v formic acid was pumped through a quartz reactor where it was exposed to UV radiation (100–280 nm) to generate Hg vapour. This vapour was preconcentrated onto a SPME fibre in the gas–liquid separator under stopped-flow conditions and the fibre then transferred to the TD port of the MIP-AES instrument. The results of 133 ± 5 mg kg−1 obtained for CRM ERM CC580 (estuarine sediment) was in agreement with the certified value of 132 ± 3 mg kg−1.
There has been considerable interest in developing miniaturised atomic emission spectrometers as alternatives to pXRFS and LIBS instruments for field analysis. Different approaches have been chosen to improve analytical performance. He et al.141 developed a novel cross double-point discharge incorporating four electrodes that produced a larger microplasma than previous single-point discharge devices, thereby ensuring that a higher proportion of analyte (introduced as the hydride) was excited. The LODs of 2.4, 0.15 and 1.9 μg L−1 for As, Hg and Pb, respectively, were about a third of those previously reported. Yuan et al.142 optimised a GD-AES method using a HG-solution anode for determination of Hg with an LOD of 0.03 μg L−1. Deng et al.143 designed a compact device integrating a tungsten coil ETV atomiser and a conventional (two electrode) point-discharge microplasma in a single quartz tube. The unusually close proximity of the atomiser and plasma (optimal distance 12.5 mm) had improved transport efficiency and, hence, better LODs than devices that incorporate an interface. Results for Ag, As, Bi, Cd, Cu, In, Pb, Sb and Zn in a selection of 14 environmental CRMs were not significantly different from certified values at 95% CI. Liu et al.144 explored the use of an electromagnetically-heated tungsten boat for direct analysis of solid samples as an alternative to the use of a tungsten coil atomiser and liquid sample introduction. The excitation source was a DBD. The LODs for analysis of a 5 mg sample were 0.018, 0.008 and 3.5 mg kg−1 for Cd, Hg and Pb, respectively. Accurate analysis of 10 soil CRMs was demonstrated (t-test at 95% CI).
The optimum conditions in the first demonstration145 of LA-APGD-AES for direct determination of Cd, Pb and Zn in soil were: 28 mA discharge current, 14 mm discharge distance, 140 mL min−1 gas flow rate (3% H2 + 97% He), 60 mJ laser energy and 10 Hz laser repetition rate. Samples were presented as pressed pellets without binder. Calibration curves were obtained by analysis of CRMs covering a range of concentrations. The LODs were 0.31, 2.7 and 0.68 mg kg−1 for Cd, Pb and Zn, respectively. Results for two soil samples from different parts of China were similar to those obtained by ICP-AES but no statistical comparison was reported.
A comparison of calibration strategies for the determination of Cd, Co, Cu, Fe, Mn, Ni and Pb in soil by ICP-SFMS concluded149 that there was generally little difference between results obtained using IDA, gravimetric external calibration with gravimetric internal standardisation, and gravimetric standard addition with gravimetric internal standardisation but noted that the volumetric preparation of standards could lead to loss of accuracy.
A flow-injection slurry-sampling ICP-MS method used150 a mixed-gas plasma to achieve a high-throughput determination of Al, Cd, Cu, Fe, K, Mo and Zn in wheat flour. Sample slurry (1% m/m) in a surfactant solution (Aerosol-OT) was stable enough to be introduced without continuous agitation during sampling. The plasma gas was made up of 462 mL min−1 N2 + 18.5 L min−1 Ar and the sheath gas was 4 mL min−1 H2. Results for analysis of NIST SRM 8437 (wheat flour) were statistically similar to certified values (95% CI) for all elements except Al, which was overestimated due to polyatomic ion interferences, in particular 1H12C14N+, caused by addition of the H2 and N2. The coupling of chromatographic separation with ICP-MS continues to be of interest because of the insight it can provide into trace element speciation. Of particular note for As were two HPLC-ICP-MS methods. The first was used151 not only for speciation analysis in different tissues of rice plants but also to explore associations between As and DNA fractions. The second was applied152 together with UHPLC/ESI-MS/MS to identify As species in marine algae and algae-based foodstuffs. Another HPLC-ICP-MS method could resolve153 CrIII and CrVI in rice extracts in <4.5 min and had a LOD of 0.012 ng mL−1 for both species. An unknown Cr compound was detected that required further investigation. A novel online microdialysis-HPLC-ICP-MS system was developed154 for continuous sampling and measurement of CrVI in soil solution, thereby minimising Cr species interconversion which is the bane of conventional extraction procedures. Because the HgI species is also prone to redox instability, it is difficult to explore its role in biogeochemical processes. A new method based on 2-mercaptoethanol extraction and HPLC-ICP-MS was used successfully to detect155 HgI in plant and soil samples. The application of SEC-ICP-MS and AEC-ICP-MS aided156 the identification of new Ni-containing proteins in water extracts of Arabidopsis root.
Advances in FFF-ICP-MS included157 the first successful use of a preparative rather than an analytical asymmetric FFF instrument, thereby increasing the injection volume and sensitivity for the detection of particulate P in soil extracts. The capabilities of FFF-ICP-TOFMS and FFF-sp-ICP-TOFMS for analysis of soil spiked with engineered NPs (CeO2, Fe2O3 and TiO2 at concentrations of 0.05, 0.5 and 5 mg kg−1) were explored.158 An increase in Ce, Fe and Ti signals with increasing spike concentrations was observed when using FFF-ICP-TOFMS. However, the magnitude of the increase did not correspond to the amounts of NPs added and the signals for a range of other elements also increased. The explanation proposed was enhanced extraction of natural particles caused by introduction of residual surfactants left over from NP synthesis. It was not possible to distinguish the NPs, at least at the concentrations added, from the high background of soil particles containing Ce, Fe and Ti. However, the study demonstrates the importance of multi-element screening to avoid misinterpretation of results.
Other developments in sp-ICP-MS included159 a method for the analysis of CeO2 NPs extracted from soil with 2.5 mM tetrasodium pyrophosphate that had LODs of 15 nm particle size and 194 NPs mL−1. An assessment of aging on NP in soils found that no marked change occurred in particle size, size distribution or particle concentration over a period of one month. A LA-sp-ICP-MS study initially ablated160 Au NPs deposited on a flat polyether sulfone membrane in order to check particle size preservation and linearity of response. Subsequently, NP-doped soils were analysed. A key finding was that particle recovery was affected by the nature of the substrate on which the particles were presented to the laser. In a procedure for the sp-ICP-MS/MS analysis of TiO2 NP in plant digests, O2 was added161 to the collision/reaction cell to overcome spectral interferences on 48Ti+. Quantification of Ti was based on the 48Ti16O+ ion at m/z = 64. The size LOD was 15 nm. The method was used to study NP uptake in radish.
Studies involving elemental imaging by LA-ICP-MS included162 a cold plasma method for studying the distribution of Na in roots of Arabidopsis thaliana grown in a cultivation medium containing 0.05 nM Na. Plasma cooling was achieved by reducing the plasma power to 670 W and delivering an additional wet aerosol (dilute HNO3) to the ICP. This improved the LOD for Na two-fold. When a laser spot size of 4 μm was employed, it could be seen that Na was located in a narrow band of cells. This finding supported the hypothesis that the root epidermis may act as a diffusion barrier. The first application of LA-ICP-MS to the study of the spatial distribution of major (Ca, K, Mg and P) and trace (Co, Fe, Mn, Na and Zn) elements in the rhizosphere through analysis of soils cores (0–15 cm depth) provided163 useful information on the effects of different soil amendments and agronomic practices.
An investigation of the utility of CaF2as a dominating matrix for quantitative analysis by LA-ICP-MS used164 NIST SRM 2719a (Montana soil) as its test substrate. A mixture of 0.3 g NH4HF2 + 0.65 g CaCl2 + 0.05 g soil was heated in an electric furnace, ground and pressed into a pellet for analysis. Although promising results were obtained for Al, Fe, Mg and Mn using 44Ca+ as IS, there is a need to prove this approach for analytes present at lower concentrations.
New methods for the precise measurement of isotope ratios by MC-ICP-MS included165 a procedure that used a single cation-exchange column to separate K from sample matrix elements with a 99.5 ± 0.6% yield. That K isotopes may have greater potential as environmental tracers than previously thought was highlighted by the analysis of 23 geological and biological RMs. Whereas the δ41K values for rocks were similar to each other and consistent with published data, those for soil, sediment and plants were more varied. A single-step purification method for Sb based on a thiol-functionalised mesoporous silica powder was used129 to determine the δ123Sb values in a wide variety of CRMs with complex matrices. A double-spike MC-ICP-MS method for Cd provided130δ114/110Cd values in four soil, nine sediment and two manganese nodule CRMs that fell within the range of published data. A value (−0.08 ± 0.04 (n = 6)) for δ114/110Cd in IGGE GSD-3a (sediment) was reported for the first time.
Radionuclides in soil were a focus of ICP-MS/MS research. In a method for the determination of 236U, 0.6 mL min−1 CO2 and 7 mL min−1 He were introduced166 to the collision/reaction cell to remove interferences, in particular by converting 235U1H+ to 235U16O+. This allowed determination of 236U/238U ratios as low as 3 × 10−10, an order-of-magnitude better than previously achievable. A study conducted using NH3 and He cell gases demonstrated167 that the determination of Pu was relatively insensitive to the sample preparation method used. However, removal of Pb and U was more challenging following lithium metaborate fusion than following digestion in either aqua regia or 8 M HNO3. A procedure for the measurement of 241Am, also using He–NH3 collision–reaction gas, had168 a LOD of 0.091 fg g−1, three times better than that achievable using other types of ICP-MS. The results for the analysis of the IAEA CRMs 375 (soil) and Soil-6 of 0.758 ± 0.078 and 0.528 ± 0.055 mBq g−1 were not significantly different from the certified values of 0.71 ± 0.16 and 0.48 ± 0.10 mBq g−1, respectively. The method was applied to seven surface soils from China and a sediment from Denmark. A key step33 in a ID-ICP-MS/MS method for simultaneous determination of PGEs and Re was removal by CEC of the majority of elements likely to form isobaric or polyatomic ion interferences. The reaction gas in the collision cell was 10% NH3 in He.
Efforts have continued with the aim of improving the performance of LIBS for soil analysis. A 532 nm monomode and a 1064 nm multimode laser were compared170 using the same spectrometer system and laser fluence (460 J cm−1). A larger mass was ablated at 532 nm but the plasma temperatures and electron densities were similar for the two lasers. The superior S/N obtained for C, Fe, Mg and K in a test soil meant that use of the 1064 nm laser was recommended. The importance of optimising the energy ratio and inter-pulse delay time in DP-LIBS was demonstrated171 and the enhancement in emission line intensity, and hence sensitivity, that can be achieved by plasma spatial confinement (discussed in last year’s ASU1) was confirmed.172 The beneficial effects of using a heated target in soil analysis were demonstrated173 for the first time. When a sample spiked with Pb powder (80 ppm) was analysed at 100 and 200 °C, emission intensities for matrix elements such as Al, Ca, Fe and Si increased and spectral lines of the Pb became visible. None was visible at room temperature. The LOD for measurement at 200 °C was 3.8 ppm.
In LIBS-LIF, a second, tuneable laser is used to pump analyte atoms in the primary laser ablation plume to excited states from which emission can occur, thereby increasing emission intensities and S/N. When a LIBS-LIF method for micronutrients in soil was applied174 to a suite of 12 GBW CRMs, a linear response was obtained with LODs of 0.36, 0.48, 23, 1.2 and 1.2 ppm for B, Cu, Fe, Mn and Zn, respectively. The approach showed promise but application to CRMs not used in calibration would have been desirable.
Numerous LIBS methods for the determination of specific elements in soil have been reported and it is pleasing to note that several researchers evaluated performance by comparison with results obtained by other techniques. Noteworthy was a procedure for the determination of Cd with an LOD of 7.8 mg kg−1 that gave175 a relative error of <6.1% for analysis of soil samples previously tested by the Chinese Institute of Environmental References Materials or the Ministry of Environmental Protection. A method for estimating available-K involved176 immersing a cation-exchange membrane in a soil suspension in deionised water, shaking for 10 min, recovery of the membrane, removal of adhering soil particles by sonication, drying at 40 °C and LIBS analysis. Results agreed within 2.6% with ammonium-acetate-extractable K values. A study combined177 LIBS and VIS-NIR data from various wavelength regions using different models to estimate P concentration in 147 Danish agricultural soils. Results were compared with data for water-extractable P; available-P as defined by the method of Olsen; oxalate-extractable P; and total P obtained by wet chemical methods. The combined LIBS and VIS-NIR models with variable selection generally produced the results most similar to the reference method for all four P pools. In an improved method for the determination178 of soil C, overestimation of the analyte at 247.8561 nm due to interference from the Fe II line at 247.8572 was overcome by use of a high resolution spectrometer and a LS interference-correction method.
A design of experiments approach was used179 to optimise a multi-element LIBS method for analysis of river sediments. Both single-pulse LIBS at 1064 nm and DP-LIBS using 532 and 1064 nm lasers were studied. Parameters considered were laser energy, delay time, gate width and number of pulses accumulated (plus inter-pulse delay for DP-LIBS). The selection of optimal conditions was based on S/N contour graphs. Single- and DP-LIBS methods for determination of P were developed180 and used to analyse samples taken from sediment cores collected in two rivers in Brazil. Although results sometimes differed from those obtained by ICP-AES following HNO3 digestion, overall trends in P concentration with depth were similar.
Research on elemental analysis of plants by LIBS is generally less advanced than the analysis of soils. Although the field is advancing rapidly, method performance assessment still tends to focus on model development and internal validation using training and test sets rather than on comparison with results obtained by established methods. Procedures have been reported for the determination of: Cr and Cu in mulberry leaves;181 Al, B, Ca, Fe, K, Mg, Mn, N and P in vegetables182 and Al, Ca, Cu, Fe, K, Mg, Na, P, Si and Zn in different parts of the rice plant.183
A method for the determination of Pb in rhododendron leaves by LIBS-LIF involved184 direct analysis of solid samples following grinding, spiking with different amounts of Pb(NO3)2 solution (for standard addition calibration), drying and mounting on adhesive tape. An alternative sample preparation method, described as “solid–liquid–solid transformation” (SLST) had an intriguing name but was in fact a conventional UA digestion in 0.03 M HCl followed by spiking with the Pb(NO3)2 and drying onto glass slides. Results were compared with those obtained by ICP-AES following MAD. Unsurprisingly, the two methods involving total sample digestion gave similar results! However, the conclusion that this proves the superiority of SLST-LIBS-LIF over ICP-AES in terms of overall speed and efficiency is based on an unfair comparison, since the extracts prepared for LIBS analysis could easily have been analysed by ICP-AES without the need for MAD. It is also unclear why, given that one of the key strengths of LIBS is the ability to analyse solid sampled directly, the introduction of sample digestion and extraction steps to analytical protocols should be desirable.
In spark discharge-LIBS, electrodes are positioned just above the sample surface and held at a voltage below the spark-gap self-breakdown potential. When the laser is fired at the sample, the ablation plume expands in the gap and triggers the spark discharge which reheats the plasma and increases signal intensity. A further potential advantage is the ability to calibrate the analysis by using a single solid standard with a matrix composition similar to that of the samples and by varying the voltage applied to the electrodes, thereby avoiding the need to produce a set of solid standards with different analyte concentrations. Multi-voltage calibration was investigated185 for the determination of Al in plants and P in fertilisers, together with two other strategies that involved just one standard: (a) multi-line calibration and (b) slope ratio calibration based on accumulation of multiple laser shots. Accurate results were obtained at 95% CI for Al in NIST SRMs 1570a (spinach leaves), 1515 (apple leaves) and 1573a (tomato leaves) using all three approaches. Whereas results for P in fertilisers based on multi-voltage and slope-ratio calibration were in agreement with those obtained by HR-CS-FAAS, those based on multi-line calibration were not.
Developments in the XRFS analysis of soils focused on sample preparation and spectral interpretation. Croffie et al.189 compared sample presentation using loose powder, pressed pellet and pressed pellet with wax binder for the EDXRFS determination of 13 elements in four international soil exchange RMs ISE 952 and 961 (clay), 992 (sandy clay), and 995 (sand). Recoveries were highly dependent on both the element and the preparation method and ranged from 87% for Al in clay prepared with binder to 710% for Si in sand with pressed pellet preparation. A general overestimation (>20%) of recoveries was attributed to large particle sizes in Si-containing samples and peak overlap. Wu et al.190 corrected the overlap of As and Pb peaks by applying a Gaussian mixture statistical model and chaotic-particle-swarm optimisation, thereby providing a mechanism for more accurate element quantification. In a paper in Chinese, spectra obtained in the field in the determination of Pb were corrected191 for noise by applying harmonic analysis at different Pb concentrations and smoothed pseudo Wigner–Ville distribution.
A measuring chamber developed192 for fluorescence kinetic measurements was modified193 for the μXRFS imaging of trace elements in living plants. The measuring chamber provided the humidity and nutrients needed for continued plant growth during analysis so that the health of the pepper plant could be maintained during 20 h of irradiation with a dwell time of up to 600 ms per spot. The customised bench-top XRFS instrument was modified with a multilayer mask on the detectors to minimise spurious counts and result in cleaner spectra. The system was used for whole-leaf mapping (rather than spot measurements) of Zn in the hyperaccumulator Noccaea caerulescens and, as a result of the long irradiation time possible, was also successfully used to study the distribution of Cu, Fe, Ni and Zn in pepper leaves and soy bean roots.
Photo-induced force microscopy is a cutting-edge technique that combines the advantages of AFM with IR spectroscopy to acquire simultaneously 3D topographic data and molecular chemical information at high spatial (ca. 5 nm) and spectral (ca. 1 cm−1) resolution. A comprehensive review197 (80 references) of the technical aspects of this technique and its application to geosciences through nanoscale chemical imaging had the aim of introducing this new analytical development to a broader geochemical audience. Examples of its application included the visualisation of growth zonation in zircons and the identification of fluid speciation in high-pressure experimental samples and of nanoscale organic phases in biominerals.
An annual bibliographic survey provided198 a summary of RMs used in geochemistry and related fields, such as paleoclimate and environmental research, that featured in papers published in 2019. This review examined 6850 papers from more than 20 scientific journals and used data from nearly 700 articles. All the RM data are freely available in the GeoReM database (http://georem.mpch-mainz.gwdg.de) and all the articles are listed in an appendix. A review in Chinese (115 references) discussed199 progress in the production of geological RMs with ultrafine particle sizes in China since 2003 and their role in improving analytical accuracy.
Field-portable geochemical techniques have seen rapid development over the past two decades, so a review200 (61 references) of handheld and site-portable instruments used for mineral exploration is timely. It covered a range of techniques including core scanners, XRFS, XRD, LIBS, IR, FTIR, μRaman and gamma spectroscopies and discussed the benefits, challenges and pitfalls of field measurements as well as the balance between data quality and quantity. A comprehensive review (121 references) of field-portable and handheld LIBS provided201 an historical overview of the technique and a comparison with its main competitor, pXRFS. A detailed description of the current status of LIBS instrumentation and a wide variety of applications was presented. It was concluded that although the future for this technique was very promising, important technological advances were still required to maximise its potential. The limited availability of matrix-matched calibrants was also a major impediment to environmental applications.
Those engaged in research on mineral-hosted melt inclusions are directed to a series of recommendations202 (279 references) for sample preparation, analysis and data presentation. The paper was dedicated, by the participants and organisers of the melt-inclusion workshop held in 2018 at Woods Hole Oceanographic Institution, to Erik Hauri in recognition of his contributions to the in situ analysis of melt inclusions. The intention of these guidelines was to bring some uniformity to the characterisation of melt inclusions and to systematise data collection and reporting, thereby facilitating the comparison and evaluation of published data.
A review (250 references) of the analysis of geological materials by a wide variety of techniques provided203 a basic introduction to sample decomposition and analysis. The merits and limitations of 11 commonly used techniques for geochemical applications were discussed and some practical examples given. The same author summarised147 (178 references) the technical advances in ICP-MS made over the last three decades aimed at reducing the different types of interferences encountered. Developments discussed included the use of cool plasmas, collision/reaction cell technology, HR-ICP-MS and ICP-MS/MS. The contribution of approaches such as internal standardisation, ID, standard addition and matrix-matching calibrations to the improvement of data quality were also discussed.
Advances in laser-assisted techniques such as LA-ICP-MS and LIBS were the focus of several review papers. Recent developments related to isotopic fractionation, matrix effects and isobaric interferences in LA-MC-ICP-MS were considered204 (149 references) as well as methods for their mitigation. It was emphasised that the selection of appropriate correction methods was critical to obtain accurate and precise isotope ratios. There was, however, no universal solution and each isotope system required its own procedure dependent on the hardware available and the samples of interest. A review205 (123 references) on recent developments in LIBS analysis combined with machine learning for geochemical and environmental resources exploration, covered instrumentation, sample preparation, spectral fusion technology, field-portable and remote LIBS, machine learning methods and applications to various geological and environmental materials. The accuracy, precision and LODs of LIBS analysis constrained current applications, and substantial improvements were required to achieve potential applications.
Several studies examined natural minerals as RMs for in situ isotope ratio analysis. After screening a large number of apatite specimens from several mineral collections, Wudarska et al.210 focussed on a set of six apatite RMs with Cl mass fractions spanning a range within the apatite solid solution series. Their Cl isotope homogeneity was evaluated using SIMS and δ37Cl measured by IRMS. All six apatite RMs were deemed suitable for the calibration of in situ δ37Cl measurements. In addition, major and key trace element compositions as determined by EPMA were reported. In a related study, three Harvard tourmaline RMs (schorl 112566, dravite 108796 and elbaite 98144), already used for the calibration of in situ B isotope measurements, were characterised211 for their Li and O isotope compositions by SIMS. The Li mass fractions of these tourmalines vary over three orders of magnitude. Homogeneity tests by SIMS demonstrated that the 7Li/6Li and 18O/16O isotope ratios were constant within ±2.2 and ±0.2‰ (1SD), respectively, at sub-ng test portion masses. Reference values reported for δ18O, Δ17O and δ7Li in these tourmaline RMs were based on results for bulk mineral analyses undertaken at several independent laboratories. Any inter-laboratory bias was assessed. A new set of six tourmalines presented212 as potential RMs for in situ B isotope ratio measurements by SIMS covered an extended compositional range of tourmaline supergroup minerals, including Fe-, Li- and Mg-rich end-members. Bulk MC-ICP-MS analysis yielded B isotopic compositions ranging from −15.5‰ to −9.2‰ with uncertainties of 0.1–0.7‰ (2SD). Four existing tourmaline RMs were also re-evaluated for their major element and B isotopic compositions. For two of the RMs, a discrepancy of ca. 1.5‰ in δ11B values was observed between the previously published reference values and those determined in this study. It was concluded that a multi-analytical comparison study between different laboratories was required to elucidate fully the reasons for the differences in these results. Two materials, a natural crystallised quartz (Qinghu-Qtz) and a fused quartz (Glass-Qtz), were described213 as new RMs for in situ O isotope analysis by SIMS. Variations in δ18O of 0.50‰ (n = 1083, 2SD) for Qinghu-Qtz and 0.22‰ (n = 283, 2SD) for Glass-Qtz, indicated that both materials were homogeneous at the scale of ca. 20 μm. In comparison, NBS 28 quartz RM, a well-established quartz O-isotope RM designed for bulk analysis, was less homogeneous at this scale. Two new natural iron sulfide RMs – pyrrhotite JC-Po and pentlandite JC-Pn – were characterised214 for their Fe and S isotope compositions. Homogeneity was demonstrated by EMPA (major elements), SIMS (S isotopes) and LA-MC-ICP-MS (Fe isotopes). Recommended values for δ56Fe were based on solution MC-ICP-MS analysis whereas δ33S and δ34S were determined by IRMS. Li215 proposed a natural chalcopyrite (HTS4-6) as a RM for in situ S-isotope-ratio microanalysis after examination by SIMS and LA-MC-ICP-MS. The measurement precision for 34S/32S from both techniques was <0.39‰ (2SD). The recommended δ34S value determined by IRMS was +0.63 ± 0.16‰ (2SD, n = 23). Another chalcopyrite RM (TC1725) was described216 for in situ Cu isotope ratio measurements by LA-MC-ICP-MS. Homogeneity was evaluated by solution MC-ICP-MS analysis of bulk material and single grains as well as by fs LA-MC-ICP-MS. Results from all analytical methods agreed within uncertainties. It was concluded that chalcopyrite TC1725 was texturally and chemically sufficiently homogenous to be used as a Cu isotope RM. The recommended mean δ65Cu value for TC1725 was given as −0.06 ± 0.03‰ (2SD, n = 132) as determined by bulk solution MC-ICP-MS. It is pleasing to note that all the authors of the papers cited in this section appreciated the importance of making these new RMs available to the wider geochemical community.
New reference minerals for U–Pb geochronology studies are of continuing interest. More than 100 grains of a bastnaesite K-9 were analysed217 by EMPA, LA-ICP-MS, SIMS, ID-TIMS and ID-MC-ICP-MS to establish its credentials as a RM for element concentration and U–Th–Pb dating measurements. The homogeneity of major elements (<5 wt% RSD) was demonstrated by EPMA and that of the U–Pb and Th–Pb systems (<2% RSD) by SIMS. The recommended age data (a 206Pb/238U age of 116.80 ± 0.13 Ma and a 208Pb/232Th age of 116.59 ± 0.11 Ma) were determined by ID techniques. A natural zircon megacryst SA02 was studied218 as a potential RM for micro-beam U–Pb geochronology and Hf–O isotopic analysis. A mean ID-TIMS 206Pb/238U age of 533.7 ± 3.7 Ma (2SD, n = 8) was recommended as the working value when using untreated grains for calibration. Results obtained by SIMS and LA-ICP-MS were in agreement with the ID-TIMS data within the uncertainties of these techniques. The recommended reference value for 176Hf/177Hf was 0.282287 ± 0.000016 (2SD, n = 31) based on solution data measured by MC-ICP-MS. Homogeneity was assessed by LA-MC-ICP-MS. A mean δ18O value of 6.03 ± 0.28‰ (2SD, n = 13) determined by laser fluorination was in agreement with data obtained by SIMS.
New isotope RMs for solution-based analyses have been developed by several laboratories, particularly with the aim of comparing data for non-traditional stable isotopes. For example, the isotope RMs often used as zero-δ scale for Fe (IRMM-014) and Mg (DSM3) are either out of stock or not readily available so RM IRMM-524A (Fe solution) and ERM-AE143 (Mg solution) have been produced as alternatives by IRMM and BAM, respectively. The Fe and Mg isotope ratios for these two new materials, determined by MC-ICP-MS, were reported by de Vega et al.219 to be δ56FeIRMM-014 = −0.004 ± 0.014‰ (2SD) and δ57FeIRMM-014 = +0.005 ± 0.024‰ (2SD) for IRMM-524A (Fe), and δ26MgDSM3 = −3.295 ± 0.040‰ (2SD), and δ25MgDSM3 = −1.666 ± 0.043‰ (2SD) for ERM-AE143 (Mg). Based on these values, Fe and Mg isotopic compositions for 21 geological RMs were determined. In a parallel study, Bao et al.220 characterised GSB-Mg, a large volume (9.5 L) of a pure, concentrated and homogeneous Mg standard solution for use as a secondary RM for Mg isotope analysis. Its Mg isotope composition was determined by MC-ICP-MS at five different laboratories and quoted relative to DSM3 (a 0.3 M HNO3 solution of Mg). The reference values for the GSB-Mg standard solution were given as δ26MgDSM3 = −2.049‰ and δ25MgDSM3 = −1.056‰, with a combined expanded (k = 2) uncertainty of 0.049‰ and 0.028‰, respectively. Three new Mo isotope RMs have been developed221 by the National Institute of Metrology (China). One of these, GBW 04504, has natural isotope abundances whereas the other two are enriched in either 97Mo (GBW 04505) or 100Mo (GBW 04506). The mass bias of the MC-ICP-MS measurements was accurately corrected using five gravimetric isotope mixtures. It was claimed that these three RMs are the first with absolute Mo isotope amount ratios traceable to SI units. Another contribution222 described the development, uncertainty evaluation and certification of a set of eleven new Zn isotope RMs (GBW04465-04475) with 64Zn/66Zn ratios ranging from 0.02 to 13. They were gravimetrically prepared from enriched isotopic materials whose composition had been accurately determined by total evaporation TIMS. Traceability to the mole SI unit was claimed and reference values were validated by a between-laboratory comparison.
It is difficult to obtain marine carbonate RMs such as JCp-1 (Porites coral) and JCt-1 (giant clam) because of their animal origins so NIST prepared223 RM 8301 (boron isotopes in marine carbonate (simulated coral and foraminifera solutions)). This consists of two synthetic solutions produced to imitate typical coral and foraminifera in terms of their δ11BSRM951 values and trace element contents. Seven leading research laboratories contributed B isotope data to the characterisation of this new SRM. The assigned NIST reference values for δ11BSRM951 were 24.17 ± 0.18‰ (NIST RM 8301 (coral)) and 14.51 ± 0.17‰ (NIST RM 8301 (foram)). Use of these new solution RMs should assist the palaeoceanographic community in evaluating the quality of their analyses. A new high-purity CaCO3 isotopic RM, designated USGS44, was developed224 as a secondary isotope RM to normalise stable-C-isotope measurements to the δ13CVPDB-LSVEC scale. The δ13CVPDB-LSVEC value was 42.21 ± 0.05‰ measured by both EA and DI IRMS. Although δ18O values were reported, this new RM was not considered suitable for δ18O measurements because its fine grain size (<63 μm) may result in exchange with atmospheric water.
The development of new RMs is important for mineral exploration and environmental contamination studies. Three sediment-based RMs (SdAR-L2 (blended sediment); SdAR-M2 (metal-rich sediment); SdAR-H1 (metalliferous sediment)) described by Wilson et al.113 were designed to mimic NIST SRMs 2709-2711 for selected element mass fractions while retaining a natural mineralogy essential for matching matrix and dissolution characteristics. The reference values for over 40 elements in each material were determined as part of the IAG GeoPT proficiency testing programme.
Further characterisation of existing RMs can be helpful when there is a paucity of suitable RMs for analyses. For instance, Druce et al.225 reported δ66Zn values for 18 geological and biological RMs, some for the first time. Similarly, N mass fraction and δ15N data were published226 for 14 silicate RMs chosen to span the range of crustal signatures. The δ15N values of these RMs ranged from −0.5 to +19.8‰. Of these, USGS RM BHVO-2 (basalt) and CPRG RMs UB-N (serpentine), FK-N (feldspar) and Biotite-Fe (biotite) were considered to the most appropriate for use as QC materials as they were most reproducible in terms of N mass fraction (<10% relative error) and isotopic composition (<0.6‰, 1SD). New δ114Cd/110Cd values were reported114 for 34 geological and biological RMs. Analyses were performed with a precision of <0.074‰ (2SD) using a 111Cd–113Cd double spike technique and MC-ICP-MS.
New sample purification procedures for the determination of REEs in geological materials continue to be reported. Liu et al.229 developed a simple method using polyurethane foam to determine ultra-low amounts of REEs in iron-rich mineral samples by HR-ICP-MS. About 10–20 mg of sample powder were dissolved and then reacted with 0.14 g of foam by shaking vigorously for three hours. Under optimised conditions, over 98% of the iron was removed while recoveries for REEs and Y were between 98% and 104%. Analysis of two CCRMP RMs (iron formation FER-1 and FER-2) and one from NRCGA (GBW07267 (pyrite)) yielded results that agreed within uncertainties with previously reported values. In a chemical separation procedure for the determination of REEs and Y mass fractions in carbonates by ICP-MS, significant amounts of Ba and other alkaline earth elements were removed230 using DGA resin (TODGA) after addition of a Tm spike. Three carbonate RMs (BEAN, CAL-S, JLs-1) were used to validate the method. This procedure could be applied to other rock types or organic-rich matrices for which quantitative removal of Ba is necessary.
A comprehensive review (193 references) on elemental imaging using LIBS covered233 the technical requirements and data processing involved for successful LIBS imaging measurements. It also provided an overview of potential applications in life sciences, geosciences, cultural heritage studies and materials science. Janovszky et al.234 demonstrated the potential of LIBS mapping for classifying minerals such as biotite, feldspar, quartz and amphibole and for assessing the distribution of Be and Li within these minerals in granitic rock samples. The three statistical approaches evaluated were: classification tree based on indicator elements; linear discriminant analysis; and random forest. The results indicated that biotite and amphibole were good targets when mining for Be and Li in granitic rocks. The presentation of a method for rapid and qualitative geochemical imaging of rocks and minerals using handheld LIBS included235 an open source workflow for processing LIBS data to merge multiple raster grids and so produce cm-scale geochemical images.
The accuracy and detection limits of elemental rock analysis by LIBS are heavily dependent on the availability of robust calibration models. This is particularly true for pLIBS. Ytsma et al.236 assessed the quality of data produced by a commercial pLIBS instrument using various calibration strategies which included univariate calibration, multivariate regression modelling, the default pLIBS model predictions supplied with the instrument and an in-house calibration method based on rock RMs. Quantification of trace and minor elements with multivariate regression yielded more accurate results than with univariate models. Calibration using the new in-house method had lower prediction errors than the default models. Whereas the accuracies for major elements based on measurements of over 2000 geological RMs were satisfactory, the authors concluded that another spectroscopic technique, such as XRFS, may be preferable for in situ quantification of minor and trace elements in rocks since the errors for all calibration strategies were often greater than the average concentration of these elements in the test materials.
The potential of vacuum UV-LIBS for the quantification of S on planetary bodies without an atmosphere such as the Moon was investigated.237 Experiments were conducted in high vacuum (10−3 Pa) with a moderate laser pulse energy (25 mJ), conditions realistically achievable under the mass, size and power constraints of space flight instrumentation. An LOD of 0.5 at% S was an improvement over that achievable for lunar rocks by LIBS in the more commonly used UV/VIS/NIR spectral range.
Accurate determination of S content plays a vital role in the evaluation of coal quality. Double-pulse LIBS in a helium atmosphere enhanced238 the intensity of S spectral lines and reduced the interference from oxygen emissions. The best LOD of 0.038 wt% represented an improvement of two orders of magnitude compared to previous literature values so it was concluded that this technique had an enormous potential for online detection of S in the coal industry. Zhan et al.239 developed a simple and fast method of sample preparation for online analysis of coal by LIBS. Pulverised coal was confined in a closed cavity in the form of a “coal pillar” with a narrow opening in the side of the device through which the plasma could target the sample. The flatness of the sample surface and stability of the ablation provided good spectral quality with respect to signal intensity, RSD and S/N.
A method for the 238U–206Pb dating of young zircons by SIMS in studies of the pre-eruptive history of magma reservoirs included246 corrections for common Pb and initial 230Th disequilibrium based on theoretical considerations. An evaluation of the advantages and limitations of 238U–206Pb age determinations compared to the widely-used 238U–230Th dating of young zircons concluded that the 238U–206Pb method was more appropriate for zircons older than 150 ka but required high U and low common Pb contents. On the other hand, the 238U–230Th method was more suited to samples younger than 150 ka but it relied on a large Th/U fractionation between the zircon and magma and a high U content. A combined geochronological and geochemical study employed247 SIMS to determine the U–Pb age and REE compositions of zircons simultaneously with a spatial resolution of <10 μm. Whereas previous methods used energy filtering at relatively low mass resolution, in this procedure the SIMS instrument was operated at a high mass resolution of ca. 15000 to separate the target isotopes from complex isobaric interferences. Operation in a dynamic MC mode reduced the measurement time to 18 min per analysis. The analysis of six well-characterised zircon RMs gave U–Pb ages within ca. 1% of the recommended values and REE data consistent with those determined by SIMS and LA-ICP-MS.
Investigations of in situ dating techniques for minerals other than zircon included a study248 of the U–Pb geochronology of a collection of 11 wolframite minerals by LA-ICP-SFMS. Significant interference effects from tungsten-oxide polyatomic ions on Hg and Pb made it inappropriate to use the 204Pb correction procedure for common Pb contribution so alternative procedures using 207Pb and 208Pb were recommended. Specimens with a relatively high U content and negligible common Pb content typically gave a 206Pb/238U age precision of around 1%. Thompson et al.249 developed a LA-ICP-MS methodology for the analysis of the mineral ilmenite for major, minor and trace element concentrations and U–Pb isotopic compositions. Modifications to a typical LA-ICP-MS geochronology protocol used for other mineral phases were required because of the challenges presented by low U (tens of ng g−1) and low radiogenic Pb (<10 ng g−1 for 206Pb) contents. Results obtained using a rutile RM for calibration yielded ages comparable to ages published for other minerals from the same sample. Mercury interferences need to be taken into account when correcting for common Pb in minerals such as apatite and titanite. Gilbert and Glorie250 utilised LA-ICP-MS/MS to demonstrate that the 204Hg interference on 204Pb can be removed effectively using NH3 gas to induce a charge transfer reaction in the reaction cell, thereby making additional corrections for this interference unnecessary. Another paper on detrital apatite geochronology promoted251 the use of (U–Th–Sm)/He dating by LA-ICP-MS as a possible solution to some of the problems associated with bulk measurements of whole grains of apatite in such studies. As well as having high sample throughput and increased analytical efficiency, the spatially resolved He extraction method removed the sampling bias inherent in whole-grain methods and allowed the dating of imperfect grains with inclusions, fractures and unusual morphologies. A LASS-ICP-MS method for the rapid in situ Sm–Nd characterisation of scheelite grains acquired252 the isotope and trace element (Mo, REEs, Sr) data simultaneously. Despite some large error bars, it was concluded that this technique could be used as a rapid reconnaissance tool to constrain the age of mineral deposits when no other suitable minerals were present to characterise pathways of ore-forming fluids. Monazites often occur as minute crystals with fine textures that limit the use of analytical techniques. In the APT of nanoscale domains of monazite (0.0007 μm3 analytical volume), application of a new protocol to correct for fractionation between 232ThO2+ and 208Pb2+ resulted253 in analytical uncertainties of 15–20% on the corrected 208Pb/232Th age. This was considered to be sufficiently precise for addressing geological questions on an unprecedented small scale.
Although the Rb–Sr isotopic system has been widely employed in geochronology for decades, the advent of ICP-MS/MS instruments now makes it possible to achieve reliable in situ dating using quadrupole instruments by removing the spectral interference of 87Rb on 87Sr. Gorojovsky and Alard254 assessed laser and mass spectrometer parameters associated with in situ Rb/Sr dating by LA-ICP-MS/MS and concluded that the most accurate and reproducible results were obtained using N2O as the reaction gas in conjunction with shorter laser wavelengths (193 nm) and lower frequencies (5 Hz). Matrix-matched RMs were also recommended for obtaining accurate Rb/Sr ages. Redda et al.255 assessed matrix effects and downhole fractionation in the in situ Rb–Sr dating by LA-ICP-MS/MS of phlogopite minerals using 193 and 213 nm laser systems. They too recognised that the general lack of matrix-matched RMs was a major obstacle that affected both precision and accuracy, so they prepared a nano-powder pellet from a phlogopite RM (Mica-Mg). However, this Mica-Mg nano pellet was not ideal for use as a primary calibrant because of differences in ablation properties between it and the natural phlogopite mineral. Ages with an accuracy of 3% or better could be achieved through regular analysis of a secondary, matrix-matched, standard to assess the accuracy of the in situ Rb–Sr ages. A novel mass spectrometer with a quadrupole mass-filter and collision cell fitted to the front-end of a MC-ICP-MS/MS instrument had256 better ion transmission than that achievable with a single collector ICP-MS/MS instrument for Rb–Sr dating. The simultaneous collection of all Sr isotopes on FCs provided more precise 87Sr/86Sr ratios. The importance of mass-filtering before the collision cell for LA 87Sr/86Sr measurements was emphasised. Because only atomic ions with m/z from 82 to 92 were transmitted, accurate 87Sr/86Sr measurements could be made without any corrections for atomic or polyatomic isobaric interferences.
Developments in Re–Os isotope dating methods included257 an improved alkaline fusion procedure for the decomposition of molybdenite in a study of hydrothermal ore deposits. Powdered samples were mixed with a 50% NaOH solution, carbonised flour and an enriched Re–Os isotope spike before digestion in a Zr crucible at 700 °C. Less NaOH was required than in previous fusion methods so procedural blanks were lower at 2 and 62 pg for Os and Re, respectively. The Os and Re isotopes were measured by ICP-MS following separation of Re by absorption on an anion-exchange resin and purification of Os by distillation. This simplified procedure yielded Os blanks comparable to those of methods involving Carius tube and high-pressure ashing and had the advantages of being simpler, quicker and safer. Another paper reported258 modifications to the Carius tube digestion scheme for the NTIMS determination of the Re–Os geochronology in organic-rich sedimentary rocks. It was essential to maintain a low Re blank for samples with low Re and Os mass fractions, so the new method employed H2SO4–Na2CrO4 rather than H2SO4–CrO3 for the digestion because the purification of Na2CrO4 using an acetone extraction method was easier. The procedural blanks for Os (0.6–1 pg) and Re (1–2 pg) were an order of magnitude lower than with H2SO4–CrO3 digestion and comparable to those obtained with an inverse aqua regia digestion. Results obtained for black shale samples were consistent with those obtained following digestion with inverse aqua regia.
High signal intensities and minimised spectral interferences are necessary for precise and accurate measurements of REEs in geological samples at ultra-trace concentrations if preconcentration procedures are to be avoided. A novel method for the direct determination of REEs at very low concentrations in carbonates and peridotites involved259 the construction of an in-house heating-condensing system. This was based on a Scott double-pass spray chamber heated with an IR lamp inside an aluminium box and connected to another double-pass spray chamber covered with a Peltier-cooler device to prevent too much solvent vapour from entering the plasma. At a temperature of 180 °C, signal intensities were improved 5–8 or 6–24 times depending on the type of skimmer cone employed. The geometry of the skimmer cone was crucial to achieving higher sensitivities and the addition of N2 to the central channel of the plasma reduced oxide formation rates considerably. Wu et al.260 used a multi-REE spike and ICP-MS analysis to generate high-quality REE data that were claimed to be comparable to those obtained using high-precision ID-TIMS but within a few minutes rather than a couple of days. To facilitate calculation of the final data, a “REE Calculation Workbook” based on Microsoft Excel was made available. For the spike elements, concentrations were calculated using ID equations. Concentrations of the four monoisotopic REEs and the almost monoisotopic REEs La and Lu were calculated by comparing their intensities with intensities of unenriched isotopes of ID elements.
The challenges and limitations in the analysis of apatite by LA-ICP-MS for in situ determinations of Nd isotope ratios were summarised by Doucelance et al.261 who evaluated the influence of laser parameters such as spot size, fluence, frequency and He/N2 gas flows on measured 143Nd/144Nd, 145Nd/144Nd and 147Sm/144Nd ratios. The laser parameters had no influence on the 143Nd/144Nd and 145Nd/144Nd ratios and some cone geometries provided more precise data by MC-ICP-MS than others. For a laser spot of 40 μm, a precision of 125–150 ppm was obtained for the 143Nd/144Nd ratio. A systematic decrease in 147Sm/144Nd ratios during an analytical session resulted from a systematic instrumental drift so it was essential to normalise measured ratios to a matrix-matched RM measured under the same analytical conditions. Qian and Zhang262 reported the simultaneous in situ determination of REE concentrations (by ICP-SFMS) and Nd isotope ratio measurements (by MC-ICP-MS) in apatite by LASS-ICP-MS analysis. The measured Nd isotopic compositions for two apatite RMs (Durango and Otter Lake) agreed with their recommended values within analytical uncertainties as did the measured REE concentrations. A new microanalytical protocol was developed263 for the determination of Br, Cl and I in apatite, scapolite and silicate glass RMs by LA-ICP-MS. Ablations were performed with a range of square spot sizes (30–80 μm) using high repetition rates (25 Hz) and extended dwell times (up to 250 ms) to improve signal intensity and stability. The method was rapid (1 min per analysis) with minimal sample preparation and straightforward offline data reduction. The calculated LOQs were 8, 360 and 0.75 μg g−1 for Br, Cl and I, respectively. Results obtained on test minerals were comparable to EPMA and SIMS data on the same materials. Well-characterised matrix-matched RMs spanning a broad range of concentrations were required to identify spurious contributions to measured signals.
Imaging by LA-ICP-MS is a rapidly expanding field in the geosciences because of the wealth of spatial information it provides on geological processes. In an invited review article, Chew et al.264 (162 references) discussed advances in LA-ICP-MS methodology for this purpose and included a practical guide for setting up LA-ICP-MS multi-elemental mapping experiments. Consideration of the latest innovations in data reduction and image processing packages placed particular emphasis on quadrupole systems. Future trends included the increased use of imaging in U–Pb geochronology given that LA-ICP-QMS mapping is now capable of acquiring all the required compositional and U–Pb age information at high-spatial resolution. The LASS approach with both MC and single-collector detection showed great promise for obtaining high precision U–Pb isotope ratios and trace element data simultaneously. To support the great interest in elemental mapping by LA-ICP-MS an online app was developed265 to assist the user in fine-tuning operational conditions to avoid aliasing, minimise blur and maximise the S/N. The app generated a list of optimised conditions from which the user may choose the most appropriate set based on requirements for single- or multiple-pulse LA-ICP-QMS mapping. Neff et al.266 presented a control system for flexible LA-ICP-TOFMS imaging which synchronised movements of the translational stage, laser operation and data acquisition. The system could perform either in single pulse mode with high scanning speeds or hole drilling mode that provided lower LODs. Due to the synchronised and selective triggering in both modes, data were stored for each pixel individually to assist analysis data processing and image generation. As defined areas of interest could be ablated, imaging times shorter than those previously possible were achieved. That flexible adjustments of ablation modes could be made for specific analytical tasks was considered to be a significant advance towards fully automated element imaging.
The considerable research effort focussed on isotope ratio determinations by MC-ICP-MS and other techniques is reflected in Table 5. Because the range of elemental isotope ratios now being measured in geological materials is so diverse, a table is provided as a starting point for readers to explore the systems of most relevance to them. In general, it is difficult to discern any major breakthroughs as many of the studies provided modest improvements to existing separation procedures or analytical protocols.
Analyte | Sample matrix | Separation and purification | Detector | RMs and figures of merit | Ref. |
---|---|---|---|---|---|
Ca, Fe | Geological materials | Matrix removal on single TODGA resin column | MC-ICP-MS, TIMS | Procedure validated with USGS RMs AGV-2 andesite), BCR-2 (basalt) and BHVO-2 (basalt) | 337 |
Ca, K, Sr | Silicate rocks; calcium carbonate | 1-step separation of Ca-K-Sr based on CEC with AG50W-X12 resin | MC-ICP-MS | External reproducibility on USGS RM BCR-2 (basalt): ±0.05‰ (2SD, n = 9) for δ41K/39K, ±0.04‰ (2SD, n = 9) for δ44Ca/42Ca, and 0.000012 (2SD, n = 4) for 87Sr/86Sr | 338 |
Cd | Geological materials | 2-step Cd purification using AG-MP-1M resin and TRU resin | MC-ICP-MS | Long term repeatability of 0.00 ± 0.04‰ (2SD, n = 45) for δ114/110Cd in NIST SRM 3108 (Cd isotope solution) | 130 |
Ce | Geological RMs | Separation on AG 50W-X12 resin and purification using Ln resin. | MC-ICP-MS | Typical reproducibility ca. ±0.030‰ for δ142/140Ce in NIST SRM 3110 (Ce isotope solution) | 339 |
Ce | Rock RMs | 4-column ion chromatography using resins AG1-X8 (Fe removal), AG50W-X8 (REE separation), HDEHP (Ce separation) and G50W-X8 (Na removal) | MC-ICP-MS | Reproducibility of 0.03‰ (2SD) for δ142/140Ce obtained for Ce Ames metal standard | 340 |
Cu | Cu minerals | No chromatography after digestion in 4M HNO3 | MC-ICP-MS | NWU-Cu-A and NWU-Cu-B Cu solutions prepared from pure Cu used as RMs; results reported relative to NIST SRM 976 (Cu isotopes) | 341 |
Cu, Pb, Zn | Geological RMs | AG MP1 resin for Cu and Zn separation and Cu purification, Eichrom Pb resin for Pb separation | MC-ICP-MS | Measurement precision <±0.03‰ (2SD) for δ65/63Cu and δ64/66Zn. Validation using 5 USGS RMs for Cu and Zn, NIST SRM 981 (Pb isotopes) for Pb | 342 |
Dy, Er, Yb | Geological materials | CEC on AG50W-X8 resin to collect REE followed by 2-column separation and purification on Eichrom Ln resin | TIMS | Validation using GSJ RMs JB-2 (basalt) and JG-2 (granite) | 343 |
Fe | Geological RMs | Glasses prepared from geological RMs | Fs-LA-MC-ICP-MS | Precision <0.15‰ (2SD) for δ56/54Fe. USGS and MPI-DING reference glasses | 344 |
K | Geological and environmental RMs | Single column CEC with AG50W-X12 resin | MC-ICP-MS | Precision <±0.06‰ (2SD) for δ41/39K. Range of geological RMs | 165 |
K | Terrestrial and lunar rocks | 2-step CEC on AG50-X8 resin | MC-ICP-MS | Precision ca. 0.05‰ (2SD) for δ41/39K. Range of geological RMs | 345 |
Mg | Carbonates | Single step chromatography on Eichrom DGA resin | MC-ICP-MS | Precision ca. 0.13‰ for δ26/24Mg. Validation using GSJ RM JDo-1 (dolomite) | 346 |
Ni | Igneous rocks | 2-step AEC on AG1-X8 resin | MC-ICP-MS | Precision ±0.032‰ (2SD) for δ60/58Ni. Range of geological RMs; data reported relative to NIST SRM 986 (Zn isotopes) | 347 |
Os | Os RM solution | No sample preparation | N-TIMS | Intermediate measurement precision of 85 ppm for 186Os/188Os (2SD) for IAG DROsS RM (Os isotope solution) | 348 |
Pb | Geological RMs | AEC on AG 1-X8 resin | MC-ICP-MS | GSJ RMs JA-1 (andesite) and JMn-1 (manganese nodule). Reproducibility <±0.0032‰ (2SD) for 206Pb/204Pb and 207Pb/204Pb, <±0.0069‰ (2SD) for 208Pb/204Pb | 349 |
S | Calcium sulfate and carbonates | S converted to sulfate and purified by AEC on AG1-X8 resin | MC-ICP-MS | Precision of 0.2‰ (2SD) for δ34S; method validation assessed by comparison with EA-IRMS values on a variety of materials | 350 |
Sb | Geological materials | 2-step chromatography on AG 1-X4 and AG 50W-X8 resins | MC-ICP-MS | Reproducibility <0.04‰ for δ123/121Sb; data reported relative to NIST SRM 3102a (Sb isotopes). Standard addition with in-house synthetic solution for validation | 351 |
Si | Silicate rocks | Laser fusion of rock powders to produce fused glasses | fs-LA-MC-ICP-MS | Measurement precisions of 0.06–0.11‰ for δ29/28Si and 0.10–0.17‰ for δ30/28Si. Five USGS RMs for method assessment | 352 |
U | Zircon and titanite RMs | RMs mounted in resin and polished to obtain flat surface | LA-MC-ICP-MS | Typical precisions were 1‰ (2SD) for 235U/238U and 7‰ (2SD) for 234U/238U. Zircon RMs for validation | 353 |
W | Terrestrial rocks, mainly basalts | Organic solvent extraction with 4-methyl-2-pentanone and purification by CEC (AG50W-X8) and AEC (AG 1-X8) | MC-ICP-MS | Reproducibility of 6–9 ppm (2SD) for μ182/184W. GSJ RM JB-2 (basalt) for validation | 354 |
Zn | Geological and cosmochemical samples | 2-step AEC using Eichrom AG1-X8 resin | MC-ICP-MS | Analytical precision of 0.02‰ (2SD) for 66Zn/64Zn in JMC-Lyon (Zn solution). Four USGS and one GSJ RM used to assess accuracy | 355 |
Zn | Geological and biological RMs | 2-step AEC using AG-MP1 resin | MC-ICP-MS | Measurement precision <0.02‰ for 66Zn/64Zn. IRMM-3702 used as the primary RM and values reported relative to JMC-Lyon (Zn solution) | 225 |
Zr | Zoned zircons | Two-column purification procedure, Eichrom Ln-Spec and AG1-X8 resins | MC-ICP-MS | External reproducibility ±28 ppm for μ94/90Zr; RM zircon 91500 for validation | 356 |
Zr | Zr standard solutions | Dilution of stock solutions in 1% HNO3 | MC-ICP-MS | Assessment of new Zr isotope RM (NRCC ZIRC-1) using the regression method with 2 NIST isotope SRMs 984 (Rb) and 987 (Sr) | 357 |
Isotope ratio measurements in biogenic carbonates is of great relevance to studies of climate change and geological processes. To assess the intercomparability of B isotope data generated in different laboratories, a group of researchers set up267 the “Boron Isotope Intercomparison Project” in which two GSJ marine carbonate CRMs JCp-1 (Porites sp.) and JCt-1 (giant clam, Tridacna gigas) were analysed by 10 laboratories, mainly by MC-ICP-MS. The study included a comparison of different sample handling and mass spectrometric approaches. More consistent B isotope results were obtained if the carbonate CRMs were exposed to moderate oxidative treatment prior to sample dissolution. Overall, there was encouragingly good agreement of δ11B values obtained by participating laboratories, with the distribution of laboratory mean values being close to commonly reported in-house intermediate precisions. A new analytical approach to the measurement of Mg isotopes in biogenic carbonates using LA-MC-ICP-MS demonstrated268 that accurate δ26Mg data could be achieved by avoiding scattered Na ions and removing interferences arising from the carbonate matrix. Analytical biases of up to 3‰ were observed when analysing carbonates with significant Fe or Mn content (ca. 1%) but this could be limited to 0.2‰ in carbonates with low trace metal contents typical in many marine calcifiers. The method was applied in an assessment of the sub-μm diurnal variability of δ26Mg in planktonic foraminifera and could be adapted for the analysis of other inorganic carbonates such as speleothems and carbonatites.
An investigation of instrumental mass bias resulting from oxide formation in the measurement of Nd isotope ratios by MC-ICP-MS looked269 at several instrumental set-ups, including wet and dry plasmas, different introduction methods, the addition of N2 and various sampler and skimmer cone geometries. A mathematical model was developed from this extensive dataset to describe the behaviour of Nd isotopic ratios for a range of oxide formation rates and different instrument settings. A qualitative model predicted the correction to Nd isotope measurements required to account for contributions from the major sources of mass bias. In addition, a series of recommendations was given for improving the data quality of Nd isotope ratio determinations by MC-ICP-MS.
Simultaneous determination of S isotope ratios and trace element chemistry by fs-LASS-ICP-MS was reported270 for a range of sulfide and sulfate samples. Trace element quantification was performed by ICP-QMS and stable S isotope ratio measurements by MC-ICP-MS. The use of fs LA allowed matrix-independent calibration of the stable S isotope ratios to be made using IAEA-S-1 (silver sulfide) as the bracketing standard. However, the accuracy and precision of the trace element analysis were restricted by the limited availability of homogeneous RMs. Quantification of major and trace elements at only the μg g−1 level was considered to be acceptable given the additional information on S isotope composition that could be obtained simultaneously.
New free software called Iso-Compass was developed271 for data reduction of isotope data measurements by LA-MC-ICP-MS. Features highlighted included: a simple user-friendly interface for data input; manually defined selection of laser and background signals; corrections for background, interferences and mass bias; visual data presentation; and formatted data output for easier and more efficient processing of LA-MC-ICP-MS data. The flexible nature of the software enabled Iso-Compass to be used for various isotope systems.
Table 5 includes a number of recent papers on isotope ratio determinations by TIMS listed by element as a starting point for readers to explore the systems of most relevance to them.
A method for the preparation of fused glass discs in the determination of major and minor elements by WDXRFS needed277 only 30 mg of sample with a sample to flux ratio of 1:100 to produce normal-sized glass discs ca. 30 mm in diameter that could be measured in most laboratories. The fused discs were prepared using an automatic fluxer and their homogeneity evaluated using μ-XRFS mapping. Although the agreement with certified values was satisfactory for major elements, the 100-fold dilution factor resulted in unreliable data for many minor elements. A useful comparison of the advantages and drawbacks of this method with previously published fusion methods for small sample masses was presented.
A review (70 references) of the latest available pXRF technologies focussed278 on the determination of light elements, in particular Al, Mg, Na and Si. Quantification through numerical modelling of the variables that attenuate X-ray energies identified the distance between the sample and the detector as the key limiting factor. The use of a helium flush significantly improved the X-ray transmission effectiveness for both Mg and Na. The combination of helium flush with a new graphene detector window assembly in place of a traditional beryllium one significantly reduced scanning times without compromising precision.
2D | two dimensional |
3D | three dimensional |
AAS | atomic absorption spectrometry |
AB | arsenobetaine |
AC | arsenocholine |
ACGIH | American Conference of Governmental Industrial Hygienists |
ACSM | aerosol chemical speciation monitor |
AEC | anion exchange chromatography |
AED | atomic emission detector |
AES | atomic emission spectrometry |
AF | atomic fluorescence |
AFS | atomic fluorescence spectrometry |
AMS | accelerator mass spectrometry |
ANN | artificial neural networks |
APDC | ammonium pyrrolidine dithiocarbamate |
APGD | atmospheric pressure glow discharge |
ASU | atomic spectrometry update |
BARGE | Bioaccessibility Research Group of Europe |
APT | atom probe tomography |
BAM | Bundesamt für Materialforschung und Prüfung (Germany) |
BAS | Bureau of Analysed Samples |
BCR | Community Bureau of Reference (of the Commission of the European Communities) |
BMEMC | Beijing Municipal Environmental Protection Monitoring Center |
BPNN | back-propagation neural network |
C18 | octyldecylsilane |
CA | chemical abrasion |
CABM | Canadian Aerosol Baseline Measurement |
CAPMoN | Canadian Air and Precipitation Monitoring Network |
CAS | Chemical Abstracts Service |
CC | collision cell |
CCD | charged coupled device |
CCP | capacitively coupled plasma |
CCRM | Canadian Certified Reference Material |
CE | cation exchange |
CEC | cation exchange chromatography |
CEN | European Committee for Standardisation |
CF | continuous flow |
CFA | continuous flow analysis |
CI | confidence interval |
CISED | chemometric identification of substrates and element distribution |
CNT | carbon nanotube |
CPE | cloud point extraction |
cps | counts per second |
CRM | certified reference material |
CRPG | Centre de Recherches Pétrographiques et Géochimiques (France) |
CS | continuum source |
CT | computer tomography |
CV | cold vapour |
CVG | cold vapour generation |
Cys | cysteine |
DA | discriminant analysis |
DBD | dielectric barrier discharge |
DDTC | diethyldithiocarbamate |
dDIHEN | demountable direct injection high efficiency nebuliser |
DDTP | diethyldithiophosphoric acid |
DES | deep eutectic solvent |
DGA | diglycolamide |
DGT | diffusive gradients in thin films |
DI | dual inlet |
DLS | dynamic light scattering |
DLLME | dispersive liquid liquid microextraction |
DMA | dimethylarsinic acid |
DNA | deoxyribonucleic acid |
DP | double pulse |
DPM | diesel particulate matter |
DRS | differential reflectance spectroscopy |
DSC | differential scanning calorimetry |
DTPA | diethylenetriamine pentaacetate |
EA | elemental analyser |
EC | elemental carbon |
ED | energy dispersive |
EDS | energy dispersive (X-ray) spectrometry |
EDTA | ethylenediaminetetraacetic acid |
EDXRFS | energy dispersive X-ray fluorescence spectrometry |
EM | electron multiplier |
EMBRAPA | Empresa Brasileira de Pesquisa Agropecuária (Brazilian Agricultural Research Association) |
EMPA | electron microprobe analysis |
EMPIR | European Metrology Programme for Innovation and Research |
EN | European Committee for Standardisation |
EPMA | electron probe microanalysis |
ERM | European Reference Material |
ESI | electrospray ionisation |
ETAAS | electrothermal atomic absorption spectrometry |
EtHg | ethylmercury |
ETMAS | electrothermal molecular absorption spectrometry |
ETV | electrothermal vaporisation |
EU | European Union |
EUSAAR | European Supersites for Atmospheric Aerosol Research |
FAAS | flame atomic absorption spectrometry |
FC | Faraday cup |
FFF | field flow fractionation |
FI | flow injection |
FIA | flow injection analysis |
FTIR | Fourier transform infrared |
GC | gas chromatography |
GD | glow discharge |
GF | graphite furnace |
GLM | generalised linear model |
GO | graphene oxide |
GSBZ | Institute for Environmental Reference Materials, Ministry of Environmental Protection of China, Beijing, China |
GSD | geometric standard deviation |
GSJ | Geological Survey of Japan |
HDEHP | bis(2-ethylhexyl)phosphoric acid |
HEN | high efficiency nebuliser |
HFSE | high field strength element |
HG | hydride generation |
HILIC | hydrophilic interaction liquid chromatography |
HPA | high pressure asher |
HPLC | high performance liquid chromatography |
HPS | High Purity Standards (USA) |
HR | high resolution |
HSL | Health and Safety Laboratory (Health and Safety Executive, UK) |
iHg | inorganic mercury |
IAEA | International Atomic Energy Authority |
IAG | International Association of Geoanalysts |
IAPSO | International Association for the Physical Sciences of the Ocean |
IC | ion chromatography |
ICP | inductively coupled plasma |
ID | isotope dilution |
IDA | isotope dilution analysis |
IEC | International Electrotechnical Commission |
IERM | Institute for Environmental Reference Materials (Ministry of Environmental Protection of China, Beijing, China) |
IIP | ion imprinted polymer |
IGGE | Institute of Geophysical and Geochemical Exploration, China |
IGGE | Institute of Geophysical and Geochemical Prospecting, China |
IL | ionic liquid |
ILC | interlaboratory comparison |
IMF | instrumental mass fractionation |
IMPROVE | Interagency Monitoring of Protected Visual Environments |
INAA | instrumental neutron activation analysis |
INCT | Institute of Nuclear Chemistry and Technology (Poland) |
IR | infra-red |
IRMM | Institute for Reference Materials and Measurements |
IRMS | isotope ratio mass spectrometry |
IS | internal standard |
ISE | ion selective electrode |
ISO | International Organisation for Standardization |
JRC | Joint Research Centre (of the European Union) |
JMC | Johnson Matthey Corporation |
JSAC | Japanese Society for Analytical Chemistry |
k | coverage factor |
KED | kinetic energy discrimination |
LA | laser ablation |
LASS | laser ablation split stream |
LC | liquid chromatography |
LDA | linear discriminant analysis |
LDPE | low density polyethylene |
LEAF | laser excited atomic fluorescence |
LGC | Laboratory of the Government Chemist (UK) |
LIBS | laser induced breakdown spectroscopy |
LIF | laser-induced fluorescence |
LLE | liquid liquid extraction |
LLME | liquid liquid microextraction |
LOD | limit of detection |
LOQ | limit of quantification |
LPME | liquid phase microextraction |
LREE | light rare earth element |
LS | least squares |
MAD | microwave-assisted digestion |
MAE | microwave-assisted extraction |
MALDI | matrix-assisted laser desorption and ionisation |
MC | multicollector |
MDL | method detection limit |
MFC | mass flow controller |
MeHg | methylmercury |
MIL | magnetic ionic liquid |
MIP | microwave-induced plasma |
MIR | mid infrared |
MMA | monomethylarsonic acid |
MOF | metal organic framework |
MPI-DING | Max Planck Institute |
MRI | magnetic resonance imaging |
MS | mass spectrometry |
MS/MS | tandem mass spectrometry |
MTZ | Mud Tank zircon |
MU | measurement uncertainty |
MWCNT | multiwalled carbon nanotube |
m/z | mass to charge ratio |
NACIS | National Analysis Centre for Iron and Steel (China) |
NBS | National Bureau of Standards (USA) |
NCS | NCS Testing Co., Ltd (China) |
NDIR | non dispersive infra red |
NIES | National Institute for Environmental Studies |
NIOSH | National Institute of Occupational Safety and Health |
NIR | near infra-red |
NIST | National Institute of Standards and Technology |
NMIA | National Measurement Institute of Australia |
NMIJ | National Metrology Institute of Japan |
NP | nanoparticle |
NRCC | National Research Council of Canada |
NRCCRM | National Research Centre for Certified Reference Materials (China) |
NRCGA | National Research Centre for Geoanalysis (China) |
NTIMS | negative thermal ionisation mass spectrometry |
NWRI | National Water Research Institute |
OC | organic carbon |
PCA | principal component analysis |
PDO | protected designation of origin |
PET | polyethylene terephthalate |
PFA | perfluoroalkoxy alkane |
PGE | platinum group element |
PIXE | particle-induced X-ray emission |
pLIBS | portable laser induced breakdown spectroscopy |
PLM | polarised light microscopy |
PLS | partial least squares |
PLSR | partial least square regression |
PM | particulate matter |
PM0.1 | particulate matter (with an aerodynamic diameter of up to 0.1 μm) |
PM0.5 | particulate matter (with an aerodynamic diameter of up to 0.5 μm) |
PM1 | particulate matter (with an aerodynamic diameter of up to 1.0 μm) |
PM2.5 | particulate matter (with an aerodynamic diameter of up to 2.5 μm) |
PM10 | particulate matter (with an aerodynamic diameter of up to 10 μm) |
pptv | parts per trillion (by volume) |
PSL | polystryrene latex (particles) |
PTE | potentially toxic element |
PTFE | polytetrafluoroethylene |
PUF | polyurethane foam |
PVG | photochemical vapour generation |
pXRFS | portable X-ray fluorescence spectrometry |
Q | quadrupole |
QA | quality assurance |
QC | quality control |
QCL | quantum cascade laser |
QMS | quadrupole mass spectrometry |
RCC | rotating coiled column |
RCS | respirable crystalline silica |
REE | rare earth element |
REP | relative error of prediction |
RM | reference material |
RMSE | root mean square error |
RNA | ribonucleic acid |
RPD | relative percentage difference |
RSD | relative standard deviation |
RSF | relative sensitivity factor |
SARM | Service d’Analyses des Roches et des Minéraux (France) |
SAX | strong anion exchange |
SCX | strong cation exchange |
SD | standard deviation |
SEC | size exclusion chromatography |
SEM | scanning electron microscopy |
SF | sector field |
SFMS | sector field mass spectrometry |
SFOD | solidification of floating organic drop |
SFODME | solidified floating organic drop microextraction |
SHRIMP | sensitive high resolution ion microprobe |
SI | Système International (d’unités) |
SIMS | secondary ion mass spectrometry |
S/N | signal to noise ratio |
SOM | soil organic matter |
sp | single particle |
SPE | solid-phase extraction |
SPME | solid-phase microextraction |
SQT | slotted quartz tube |
SRM | standard reference material |
SS | solid sampling |
SSB | sample standard bracketing |
SVM | support vector machine |
SVR | support vector regression |
TC | total carbon |
TD | thermal desorption |
TE | total evaporation |
TEOM | tapered element oscillating microbalance |
TEM | transmission electron microscopy |
THF | tetrahydrofuran |
TLC | thin layer chromatography |
TIMS | thermal ionisation mass spectrometry |
TOF | time-of-flight |
TOFMS | time-of-flight mass spectrometry |
TOT | thermal optical transmission |
TXRF | total reflection X-ray fluorescence |
TXRFS | total reflection X-ray fluorescence spectrometry |
UA | ultrasound-assisted |
UBM | unified bioaccessibility method |
UHPLC | ultra high performance liquid chromatography |
UNC | University of North Carolina |
US EPA | United States Environmental Protection Agency |
USGS | United States Geological Survey |
UTEVA | uranium and tetravalent actinides |
UV | ultraviolet |
VAME | vortex-assisted microextraction |
VIS | visible |
VOAG | vibrating orifice mondisperse aerosol generator |
VOC | volatile organic carbon |
VPDB | Vienna Pee Bee Belemnite |
VSL | Dutch Metrology Institute |
WDXRFS | wavelength dispersive X-ray fluorescence spectrometry |
WWTP | waste water treatment plant |
XAFS | X-ray absorption fine structure |
XANES | X-ray absorption near edge structure |
XAS | X-ray absorption spectroscopy |
XFM | X-ray fluorescence microscopy |
XRD | X-ray diffraction |
XRF | X-ray fluorescence |
XRFS | X-ray fluorescence spectrometry |
Z | atomic number |
Footnote |
† Review coordinator. |
This journal is © The Royal Society of Chemistry 2022 |