Issue 21, 2015

Molecularly imprinted polymer-based chemiluminescence imaging assay for the determination of ethopabate residues in chicken muscle

Abstract

A new molecularly imprinted polymer (MIP)-chemiluminescence (CL) method has been developed for the detection of ethopabate (ETP) residues in chicken muscle. The MIP microspheres were prepared using precipitation polymerization with ETP as a template, methacrylic acid as a functional monomer and pentaerythritol triacrylate as a cross-linker in the porogen of acetonitrile. The prepared MIP microspheres were characterized by using a scanning electron microscope, differential scanning calorimeter and Fourier transform infrared spectrometer. The binding properties of ETP on the imprinted polymers were evaluated by the equilibrium rebinding experiment. It was revealed that two classes of binding sites were produced in the resulting ETP MIPs with the dissociation constants of 23.92 μg L−1 and 77.82 μg L−1, and the affinity binding sites of 8808.28 μg g−1 and 14 043.90 μg g−1, respectively. As the artificial biomimetic recognition element for ETP, the polymer microspheres were immobilized in microtiter plates (96 wells) with poly(vinyl alcohol) as a glue. Through the optimization of the MIP absorption and CL imaging conditions, ETP was quantified based on the peroxyoxalate CL reaction enhanced by imidazole. Under the optimum conditions, the relative CL intensity has a linear relationship with the ETP concentration in the range of 0.1 μg mL−1 to 30 μg mL−1, with a limit of detection of 14.7 μg kg−1 and a limit of qualification of 20.4 μg kg−1 in chicken muscle. The recoveries of spiked ETP are in the range of 99.80% to 99.98% with a relative standard deviation of 1.7% to 3.4%. For the first time, the CL method combined with MIPs was developed to determine trace ETP in real samples, and the results show that it can become a useful analytical tool for quick detection in residue analysis.

Graphical abstract: Molecularly imprinted polymer-based chemiluminescence imaging assay for the determination of ethopabate residues in chicken muscle

Article information

Article type
Paper
Submitted
18 jul. 2015
Accepted
16 sep. 2015
First published
21 sep. 2015

Anal. Methods, 2015,7, 9295-9303

Author version available

Molecularly imprinted polymer-based chemiluminescence imaging assay for the determination of ethopabate residues in chicken muscle

Z. Li, Z. Li, D. Li, H. Gao, X. Chen, L. Cao, Y. Hou and S. Li, Anal. Methods, 2015, 7, 9295 DOI: 10.1039/C5AY01874A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements