Issue 37, 2022

How to calibrate luminescent crossover thermometers: a note on “quasi”-Boltzmann systems

Abstract

Luminescent thermometers are potential material candidates for remote and non-invasive temperature sensing by means of a temperature-dependent optical signal. A particularly well-known class of luminescent thermometers are Boltzmann thermometers that rely on thermal coupling between two excited levels from the same configuration. Their thermal coupling kinetics is then governed by multiphonon transitions. A substantial part of potential luminescent thermometers does, however, rely on an interconfigurational crossover between two excited state potentials with differing equilibrium metal-ligand distances such as Cr3+ or Pr3+. These thermometers are often characterized by much higher intrinsic non-radiative coupling rates that allow exploiting a much higher energy gap for high relative sensitivities at appreciably low temperatures. For this class of luminescent thermometers, fitting models are often merely effective and no clear guidelines on how to tune them or how to verify the physical reliability of the fit are available. In this work, we derive a generalized fitting model for luminescent crossover thermometers and demonstrate that they generally follow a “quasi”-Boltzmann law. We explicitly demonstrate the concepts on the established phosphor SrB4O7 : 0.5% Sm2+. In this compound, Sm2+ can be efficiently excited with blue light and shows intense red 5D07FJ (J = 0…6) luminescence above 680 nm and broad-banded 4f55d1 → 4f6-related luminescence peaking at 585 nm. By additional time-resolved measurements, it is possible to independently assess the expected order of magnitude of the fitting parameters and thus, judge the physical content of the calibration model of a luminescent crossover thermometer. It is finally shown that crossover thermometers are characterized by high relative sensitivities and low-temperature measurement uncertainty at elevated temperatures but their liability toward thermal quenching poses a serious limitation to the dynamic working range of this class of thermometers.

Graphical abstract: How to calibrate luminescent crossover thermometers: a note on “quasi”-Boltzmann systems

Supplementary files

Article information

Article type
Paper
Submitted
22 mar. 2022
Accepted
23 abr. 2022
First published
26 abr. 2022
This article is Open Access
Creative Commons BY license

J. Mater. Chem. C, 2022,10, 13805-13814

How to calibrate luminescent crossover thermometers: a note on “quasi”-Boltzmann systems

B. Bendel and M. Suta, J. Mater. Chem. C, 2022, 10, 13805 DOI: 10.1039/D2TC01152B

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements