Issue 2, 2014

Evaluation of a digestion procedure based on the use of diluted nitric acid solutions and H2O2 for the multielement determination of whole milk powder and bovine liver by ICP-based techniques

Abstract

Many efforts have been made in order to reduce the amount of reagents and waste produced in analytical laboratories. However, suitable digestion efficiency must be considered, and depending on the sample preparation procedure, incomplete digestion can result in severe matrix effects during analysis by spectrometric techniques such as ICP OES and ICP-MS. In the present work a procedure based on the use of H2O2 was developed in order to minimize the consumption of HNO3 without decreasing the efficiency of digestion. Although H2O2 has been used combined with HNO3 for sample digestion, its role is still not completely elucidated even as its action combined with O2 in pressurized systems. The performance obtained using H2O2 was similar to that observed when adding O2 to the reaction vessel, driving the better understanding of the role of H2O2 in closed digestion procedures. Digestion using H2O2 allowed the use of HNO3 solutions as diluted as 1 mol L−1 to digest sample masses of biological materials as high as 500 mg. The proposed procedure allowed a reduction of up to 14 and 9.3-fold in the HNO3 amount normally used in whole milk powder and bovine liver digestions, respectively, without decreasing the digestion efficiency. Calcium, Cu, Fe, K, Mg, Mn, Mo, Na, and Zn were determined by ICP OES, while Cd, Co, and Pb were determined by ICP-MS. Using diluted HNO3 solution low blank values were obtained resulting in relatively lower limits of detection and relative standard deviations. The accuracy was evaluated by using certified reference materials of milk powder and bovine liver (agreement was better than 95% to certified values for all evaluated analytes).

Graphical abstract: Evaluation of a digestion procedure based on the use of diluted nitric acid solutions and H2O2 for the multielement determination of whole milk powder and bovine liver by ICP-based techniques

Supplementary files

Article information

Article type
Paper
Submitted
02 Oct 2013
Accepted
21 Nov 2013
First published
22 Nov 2013

J. Anal. At. Spectrom., 2014,29, 332-338

Evaluation of a digestion procedure based on the use of diluted nitric acid solutions and H2O2 for the multielement determination of whole milk powder and bovine liver by ICP-based techniques

C. A. Bizzi, E. L. M. Flores, J. A. Nóbrega, J. S. S. Oliveira, L. Schmidt and S. R. Mortari, J. Anal. At. Spectrom., 2014, 29, 332 DOI: 10.1039/C3JA50330E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements