Issue 6, 1999

The evaluation of a low resolution Fourier transform infrared (FTIR) gas analyser for monitoring of solvent emission rates under field conditions

Abstract

The applicability of a low resolution (8 cm–1) Fourier transform infrared (FTIR) gas analyser with an absorption path length of 3 m was evaluated for the on-line monitoring of organic solvent mixture emissions in a flexographic ink manufacturing plant. The on-line monitoring revealed that the highest variations of solvent concentrations, up to three decades, occurred in the exhaust air. The FTIR analyser with a dynamic range of four decades covers well the concentration ranges typically found in the exhaust air and in the workroom air of ink manufacturing plants. The average emission rate of solvent mixture based on a sampling period of two days was 1.8 kg h–1 consisting of mainly ethanol (70%), ethyl acetate (15%) and propan-2-ol (11%). The detection limits of the analyser for the solvent compounds ranged from 0.3 to 4.3 mg m–3 and the measurement uncertainty was less than 10% in the concentration range of 8–15 000 mg m–3. These characteristics make the apparatus appropriate for most industrial hygiene applications. An FTIR spectrophotometer, equipped with an multipoint sampling unit, facilitates rapid identification of solvent components, real-time display of concentration data relevant to workroom air and environment monitoring as well as process control. Furthermore, the on-line concentration information enabled a rapid selection of representative sampling locations. The spectrophotometer is transportable, rugged and relatively simple to calibrate even in a hostile industrial environment.

Article information

Article type
Paper

J. Environ. Monit., 1999,1, 549-552

The evaluation of a low resolution Fourier transform infrared (FTIR) gas analyser for monitoring of solvent emission rates under field conditions

J. Räisänen and R. Niemelä, J. Environ. Monit., 1999, 1, 549 DOI: 10.1039/A907101F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements