Magnetic smartphone microflow cytometry enables rapid CD4/CD8 T cell quantification

Abstract

Accurate enumeration of CD4+ and CD8+ T lymphocytes is essential for HIV management, yet conventional flow cytometry remains largely inaccessible in resource-limited settings. Current point-of-care testing (POCT) approaches, including lateral flow assays and fluorescence-based imaging methods, offer improved accessibility but typically compromise accuracy and yield semi-quantitative results. Here, we present a magnetic-activated smartphone microflow cytometry (MACC) platform that enables rapid, highly accessible, and fully quantitative T lymphocyte counting at the POCT. MACC integrates microfluidic immunomagnetic cell separation with smartphone-based bright-field imaging, providing high-sensitivity, highly accessible analysis without requiring sophisticated laboratory equipment or fluorescent labels. A degassing-driven microfluidic pumping mechanism ensures stable microflow generation for reliable continuous analysis, while smartphone imaging enables clear differentiation of targeted lymphocytes from non-lymphocytes. The complete assay, including magnetic bead labeling, chip operation, hands-on procedures, and automated cell-counting analysis, is completed within 24 min. Validation with HIV-infected patient samples demonstrated strong concordance between MACC and conventional flow cytometry for CD4+ and CD8+ counts as well as CD4/CD8 ratio measurements, with minimal bias. By combining high accessibility, cost-effectiveness, and ease of operation, MACC represents a promising alternative to traditional methods, facilitating decentralized HIV monitoring and expanding diagnostic accessibility in resource-limited settings.

Graphical abstract: Magnetic smartphone microflow cytometry enables rapid CD4/CD8 T cell quantification

Supplementary files

Article information

Article type
Paper
Submitted
19 Aug 2025
Accepted
05 Dec 2025
First published
19 Dec 2025

Lab Chip, 2026, Advance Article

Magnetic smartphone microflow cytometry enables rapid CD4/CD8 T cell quantification

H. S. Shin, S. J. Lee, J. In Kim, J. H. Kim, J. Y. Choi, S. J. Jeong and S. Choi, Lab Chip, 2026, Advance Article , DOI: 10.1039/D5LC00801H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements