Automated and simultaneous in-situ determination of trace element concentrations, Lu-Hf isotopes and U-Pb ages in zircon at high-spatial-resolution by Laser Ablation Split-Stream technology

Abstract

Zircon, a ubiquitous accessory silicate enriched in trace elements (e.g., rare-earth elements, Th, U, and Hf), is widely utilized for in-situ U-Pb geochronology, trace-element, and isotopic analyses. Here, we present a novel laser-ablation split-stream (LASS) technique enabling simultaneous, automated determination of zircon U-Pb ages, trace-element concentrations, and Hf isotopic compositions at a spatial resolution of 29 μm. This method integrates a laser ablation system with both multi-collector (MC) and quadrupole (Q) inductively coupled plasma mass spectrometers (ICP-MS). Key innovations include optimized gas transfer lines (4 mm and 2.5 mm inner diameters) that ensure stable aerosol splitting without additional mass flow controllers (MFCs), and the introduction of trace water vapor to enhance uranium sensitivity (~70% increase) while suppressing oxide formation (<1%) during Q-ICP-MS analysis. Data were automatically processed using the built-in “3D Trace Elements DRS”, “U-Pb Geochronology DRS”, and a custom-designed “Hf isotope_LCG DRS” in IOLITE software. Validation against well-characterized reference zircons (91500, Qinghu, Plešovice, Penglai, Tanz, MUNZirc) and glass standards (NIST SRM 610, USGS BHVO-2G, BCR-2G) demonstrated high accuracy: trace-element concentrations, U-Pb ages, and Hf isotopic ratios deviated by <20%, <1%, and <2ε units from recommended values, respectively. The method’s precision, operational efficiency, and applicability to high-spatial-resolution analyses (spot sizes down to 29 μm) underscore its potential for advancing integrated geochronological and petrogenetic studies.

Supplementary files

Article information

Article type
Technical Note
Submitted
25 Mar 2026
Accepted
12 Jun 2026
First published
15 Jun 2026

J. Anal. At. Spectrom., 2026, Accepted Manuscript

Automated and simultaneous in-situ determination of trace element concentrations, Lu-Hf isotopes and U-Pb ages in zircon at high-spatial-resolution by Laser Ablation Split-Stream technology

G. Sun, Y. Zhang, H. Gu, Y. Li, Y. Wang, X. Gu, J. Liu, L. Dai and Z. Zhao, J. Anal. At. Spectrom., 2026, Accepted Manuscript , DOI: 10.1039/D6JA00099A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements