Investigating the impact and mechanisms of integration time on LIBS repeatability and plasma parameter inversion results

Abstract

Although a longer integration time can enhance the spectral intensity, it also obscures more information regarding plasma evolution. In this study, laser-induced plasma (LIP) is detected simultaneously by using both long-integration-time and short-integration-time spectrometers via a Y-shaped fiber, and the effect of integration time on the repeatability and the inversion of plasma parameters for laser-induced breakdown spectroscopy (LIBS) spectra is investigated. The results reveal that (1) the radiation decay rate at the same wavelength varies among different LIPs, leading to increased differences in line intensities with longer integration times. However shorter integration times theoretically improve repeatability, in fact, shorter integration times tend to improve the repeatability of strong emission lines, but reduce the repeatability of weak emission lines by reducing their signal-to-background ratios (SBRs) and signal-to-noise ratios (SNRs). (2) The radiation decay rates at different wavelengths also vary within the same plasma, causing further increases in spectral line intensity differences with longer integration times. This results in greater vertical dispersion of data points in Boltzmann or Saha–Boltzmann plots, leading to underestimated plasma temperatures. (3) Longer integration times may also lead to underestimation of electron densities derived from the Stark broadening method. This study provides significant guidance for optimizing LIBS integration parameters, improving repeatability and advancing plasma spectral diagnostics.

Graphical abstract: Investigating the impact and mechanisms of integration time on LIBS repeatability and plasma parameter inversion results

Article information

Article type
Paper
Submitted
11 Jul 2025
Accepted
03 Nov 2025
First published
01 Dec 2025

J. Anal. At. Spectrom., 2026, Advance Article

Investigating the impact and mechanisms of integration time on LIBS repeatability and plasma parameter inversion results

C. Li, Y. Bi, Z. Bao, T. Zhang, C. Liu, M. Guo and M. Wang, J. Anal. At. Spectrom., 2026, Advance Article , DOI: 10.1039/D5JA00270B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements