Humidity-independent acetone gas sensors with ppbv-level sensitivity and high selectivity, using an In2O3 microporous nanoneedle array

Abstract

The detection of ppbv-level acetone is critical for the non-invasive diagnosis of diabetes and assessment of metabolic conditions. Highly sensitive humidity-independent gas sensors are required to achieve this goal. However, conventional semiconductor metal oxide (SMO) sensors often exhibit reduced performance in humid air. To overcome these limitations, we synthesized an In2O3 microporous nanoneedle array via chemical bath deposition and thermal treatment. These nanoneedles, composed of 3.4 ± 0.8 nm nanocrystallites, were meticulously arranged into well-ordered nanorods. The array featured pores with a diameter of 1.78 nm and exhibited both cubic and hexagonal phases of In2O3. The nanoneedles were formed through heterogeneous nucleation on the alumina substrate, followed by vertical and lateral growth, which produced self-standing porous structures with increasing size over the deposition time. The In2O3 microporous nanoneedle array sensors demonstrated exceptional sensitivity to acetone among 7 VOC gases, achieving a noteworthy response (Ra·Rg−1 = 8.17 at 100 ppbv). The experimental and theoretical limits of detection (LOD) for acetone in dry air were 5 ppbv and 152 pptv, respectively. Notably, the sensor maintained an experimental LOD of 10 ppbv for acetone at 90% relative humidity (Ra·Rg−1 = 2.98 at 10 ppbv). Moreover, the sensors exhibited excellent reproducibility, fast response/recovery times, and good long-term stability. Appropriate control of the nanostructure morphology contributes to achieving humidity-independent acetone sensing without the need for hybrid materials or noble metal catalysts. This approach provides a practical and reliable strategy for acetone sensing in humid atmospheres, supporting early diabetes screening and monitoring of metabolic conditions.

Graphical abstract: Humidity-independent acetone gas sensors with ppbv-level sensitivity and high selectivity, using an In2O3 microporous nanoneedle array

Supplementary files

Article information

Article type
Paper
Submitted
25 May 2025
Accepted
25 Aug 2025
First published
04 Sep 2025

J. Mater. Chem. A, 2025, Advance Article

Humidity-independent acetone gas sensors with ppbv-level sensitivity and high selectivity, using an In2O3 microporous nanoneedle array

T. Matsuoka, P. G. Choi, S. Takami and Y. Masuda, J. Mater. Chem. A, 2025, Advance Article , DOI: 10.1039/D5TA04209G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements