Issue 31, 2025

Engineered single chain variable fragments (scFvs) with improved pH-dependent kinetics for use in continuous biosensor applications

Abstract

One challenge in the continuous monitoring of insulin lies with the unavailability of a high-affinity biological recognition element (BRE) with kinetic parameters sufficient to track fluctuating concentrations of insulin in vivo. An approach to overcome this limitation is to engineer a high-affinity BRE to selectively modulate its binding kinetics in response to an external signal. Herein, we design and evaluate changes in the pH-dependent binding kinetics of an anti-insulin single chain variable fragment (scFv) we previously employed in a point-of-care insulin sensor. We predicted the scFv structure in complex with human insulin and selected scFv residues directly involved in insulin binding for histidine substitution. We identify one mutation, T32H, that improves the pH-sensitivity of the wild-type (WT); the KD of the T32H mutant is calculated to be 145.5 ± 83.1 nM at pH 7.4 and 17.4 ± 5.1 nM at pH 6.0 – an average of an 8.4× difference between the two conditions and a 3.8× increase in pH-sensitivity from the WT. We design a bio-layer interferometry (BLI) assay to interrogate the improved pH-sensitivity of the T32H mutant in tracking fluctuating insulin concentrations in dynamic pH conditions and find that improved pH-sensitivity can be leveraged to improve biosensor regeneration. These results suggest the potential for pH-sensitive antibodies to improve the development of in vivo continuous monitoring systems.

Graphical abstract: Engineered single chain variable fragments (scFvs) with improved pH-dependent kinetics for use in continuous biosensor applications

Supplementary files

Article information

Article type
Paper
Submitted
23 Mar 2025
Accepted
30 Jun 2025
First published
17 Jul 2025
This article is Open Access
Creative Commons BY-NC license

RSC Adv., 2025,15, 25337-25348

Engineered single chain variable fragments (scFvs) with improved pH-dependent kinetics for use in continuous biosensor applications

E. D. Wilson, D. Probst, M. Hamasaki, M. Oda, V. Kochar, Q. Xu, A. Tanaka, H. Suzuki, R. Asano and K. Sode, RSC Adv., 2025, 15, 25337 DOI: 10.1039/D5RA02051D

This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence. You can use material from this article in other publications, without requesting further permission from the RSC, provided that the correct acknowledgement is given and it is not used for commercial purposes.

To request permission to reproduce material from this article in a commercial publication, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party commercial publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity