An improved radioisotope-based X-ray fluorescence system for the in vivo measurement of bone strontium

Abstract

High levels of strontium can cause impaired bone growth in children, and excess mortality in animals, but at low doses there are no known toxic effects in humans. Strontium is purported to be beneficial for post-menopausal bone density loss and strontium citrate is used as a nutritional supplement by some women. This article describes development of a system to monitor bone strontium levels quickly and accurately for use in the health risk assessment of self-administered strontium supplements. Previous radioisotope-based strontium measurements take up to 30 minutes for measurements and are not portable. The new system is comprised of a silicon drift detector (SDD) with a 109Cd source in a 180° backscatter geometry. Novel anthropomorphic phantoms were developed for system calibration from 3D printed PLA shells with strontium-doped hydroxyapatite cores. The system performance was investigated using two sources of different reported activity. During development, it was noted that while one 109Cd source did emit an order of magnitude higher 88 keV γ-rays than the other, it did not emit an order of magnitude greater fluence of silver X-rays. This is attributed to differences in source encapsulation. This lower-than-expected X-ray fluence meant that the best minimum detectable limit (MDL) was determined to be 22 μg Sr per g Ca for a 30 minutes measurement. However, low system dead times indicated that the system was not used at maximum throughput, and it is predicted that with higher fluence silver X-ray sources, the system could achieve a minimum detectable limit of 7 μg Sr per g Ca.

Graphical abstract: An improved radioisotope-based X-ray fluorescence system for the in vivo measurement of bone strontium

Supplementary files

Article information

Article type
Paper
Submitted
17 Dec 2024
Accepted
03 Mar 2025
First published
05 Mar 2025
This article is Open Access
Creative Commons BY license

J. Anal. At. Spectrom., 2025,40, 1086-1097

An improved radioisotope-based X-ray fluorescence system for the in vivo measurement of bone strontium

L. M. Bickley, E. Da Silva, D. R. Chettle and F. E. McNeill, J. Anal. At. Spectrom., 2025, 40, 1086 DOI: 10.1039/D4JA00464G

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements