Feasibility of non-invasive measurement of cardiac biomarkers using mid-infrared spectroscopy: finite element analysis and experimental validation

Abstract

Attenuated total reflectance mid-infrared (ATR-MIR) spectroscopy provides a quick and efficient way to identify protein-specific absorption spectra, making it a promising technique for the non-invasive detection of cardiac biomarkers that are thought to be direct indicators of major cardiovascular events. However, there are still questions about the effectiveness of ATR-MIR in identifying various critical cardiac biomarkers and the detection depth of evanescent waves. This study employs finite element simulations to examine the optical path of attenuated total reflectance (ATR) and the detection depth of evanescent waves. To simulate a subcutaneous tissue environment, a polydimethylsiloxane (PDMS) reagent bath, a high-density melamine sponge, and a poly(ethylene terephthalate) (PET) film are used to assess the ability of MIR spectroscopy to detect cardiac biomarkers at different depths. The findings reveal that the absorption spectra of cardiac troponin I (cTnI), N-terminal pro-B-type natriuretic peptide (NT-proBNP), and C-reactive protein (CRP) show distinct characteristic peaks in the amide I and amide II bands with high specificity. At a depth of about 15 μm, the peak amplitude shows a strong correlation with the biomarker concentration. Even at a depth of 80 μm, the absorption spectrum of cTnI still displays significant characteristic peaks, confirming its ability to detect subcutaneous superficial cardiac biomarkers. This research underscores the considerable potential of ATR-MIR spectroscopy for the non-invasive detection of subcutaneous cardiac biomarkers, which could aid in the development of wearable devices for monitoring cardiovascular health, ultimately contributing to the prevention, diagnosis, and treatment of cardiovascular diseases.

Graphical abstract: Feasibility of non-invasive measurement of cardiac biomarkers using mid-infrared spectroscopy: finite element analysis and experimental validation

Supplementary files

Article information

Article type
Paper
Submitted
23 Mar 2025
Accepted
08 May 2025
First published
22 May 2025

Analyst, 2025, Advance Article

Feasibility of non-invasive measurement of cardiac biomarkers using mid-infrared spectroscopy: finite element analysis and experimental validation

Q. Zhang, Y. Xing, K. Wang, Q. Wu, Y. Zheng, J. Wu and X. Huang, Analyst, 2025, Advance Article , DOI: 10.1039/D5AN00335K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.