Abstract

The widespread industrial use of chromium and its subsequent release into the environment as toxic and carcinogenic hexavalent chromium (Cr(VI)) species pose significant risks to human health and the environment. The World Health Organization (WHO) has established a limit of 50 ppb (960 nM) for Cr(VI) in water samples. Developing simple, selective, and separation-free methods for the direct detection of Cr(VI) species in the environment remains a challenging task. Herein, we present a highly crystalline lanthanum cerate/carbon black chemically modified screen-printed electrode (SPE/CB@LaCeO3) as an effective electrochemical system for the high-performance and selective electrochemical reduction of toxic Cr(VI) species in pH 2 KCl–HCl solution. The CB@LaCeO3 composite is characterized by its high-density electroactive sites and enhanced electrical conductivity, which facilitate the efficient diffusion-controlled reduction of Cr(VI) species at a low reduction potential of 0.55 V vs. Ag/AgCl. The modified electrode demonstrated stability and resistance to surface fouling during continuous voltammetry analysis of high Cr(VI) concentrations. A batch-injection analysis using a three-in-one screen-printed electrode, comprising carbon working, silver-ink reference, and CB@LaCeO3 modified carbon working electrodes, exhibited excellent concentration linearity within the ranges of 2–30 ppb and 10–35 ppm, with a low detection limit of 682 ppt (signal-to-noise ratio, 3). This method was not interfered by dissolved oxygen or other common chemicals present in environmental and water systems. The linear range and detection limit achieved in this study surpass those reported in several previous works involving precious metal and organic molecule-based chemically modified electrodes. The analytical method was validated with t-test analysis. To demonstrate the applicability of this new system, batch injection analysis was performed on a wide range of real samples, including water (tap, ground, well, and reverse osmosis), consumable products (coffee, tea and milk powders), and tannery effluent, using the standard addition method. This approach yielded accurate and sensitive detection of Cr(VI) species in the samples, with recovery values of approximately 100%.

Graphical abstract: Ultrasensitive detection of carcinogenic chromium(vi) species below the WHO limit using a LaCeO3/carbon black screen printed electrode in batch injection analysis

Supplementary files

Transparent peer review

To support increased transparency, we offer authors the option to publish the peer review history alongside their article.

View this article’s peer review history

Article information

Article type
Paper
Submitted
11 Jan 2025
Accepted
06 Mar 2025
First published
11 Mar 2025

Analyst, 2025,150, 1754-1767

Ultrasensitive detection of carcinogenic chromium(VI) species below the WHO limit using a LaCeO3/carbon black screen printed electrode in batch injection analysis

S. Saranya, Y. K. Yashly, R. G. S. Sibiya, G. Buvaneswari and A. Senthil Kumar, Analyst, 2025, 150, 1754 DOI: 10.1039/D5AN00038F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements