Issue 48, 2024

Detection of severe acute respiratory syndrome coronavirus 2 in bioaerosols using digital droplet polymerase chain reaction and loop-mediated isothermal amplification

Abstract

In the present study, we simulated human passive breathing, sampled severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) bioaerosols, and compared the detection ability of quantitative polymerase chain reaction (qPCR), digital droplet polymerase chain reaction (ddPCR), and loop-mediated isothermal amplification (LAMP). The specificity of the primer set for the LAMP-based detection of SARS-CoV-2 was evaluated, and its sensitivity using the detection threshold in the amplification curve plots was determined. Next, we used an aerosol collection environment and collected solutions containing predetermined concentrations of plasmid containing SARS-CoV-2 N gene, which were dispersed into the environment, using a cyclone sampler. Finally, we compared the ability of qPCR, ddPCR, and LAMP in detecting SARS-CoV-2 in aerosols and stock solutions. After sampling, qPCR, LAMP and ddPCR can amplify the micro viral samples exponentially. By comparing the three assays, it was judged from the results that qPCR had a slightly higher detection limit, detecting 102 copies per μL, and therefore could not be used as a test for trace samples. qPCR, LAMP, and ddPCR were able to detect aerosol samples of 101 copies per μL. LAMP was able to qualitatively detect the samples, and ddPCR was able to quantitatively detect samples of this order of magnitude. There were 23.2 that could be used as a quantitative assay. This method can be used in public places or hospitals with limited air circulation to detect aerosol-borne viruses in trace quantities and to provide a rapid early warning.

Graphical abstract: Detection of severe acute respiratory syndrome coronavirus 2 in bioaerosols using digital droplet polymerase chain reaction and loop-mediated isothermal amplification

Article information

Article type
Paper
Submitted
30 Sep 2024
Accepted
11 Nov 2024
First published
13 Nov 2024

Anal. Methods, 2024,16, 8449-8456

Detection of severe acute respiratory syndrome coronavirus 2 in bioaerosols using digital droplet polymerase chain reaction and loop-mediated isothermal amplification

X. Zhang, Y. Guan, S. Li, Y. Deng, Y. Wu and H. Chen, Anal. Methods, 2024, 16, 8449 DOI: 10.1039/D4AY01783H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.