Issue 13, 2024

Etched stainless steel wire modified with conjugated microporous polymers-F6 for jacket-free stir bar sorptive extraction of benzoylureas in juice sample

Abstract

Benzoylurea (BU) insecticides have been widely used for pest control as third-generation insecticides. Considering that their residues in food may cause adverse effects on human health, the upper limits of BUs remaining in food have been set by the administration. Therefore, it is essential to develop a sensitive and efficient analytical method to determine the residues of BUs in food. Stir bar sorptive extraction (SBSE) is a novel sample preparation technique, and stainless steel wire (SSW) is an ideal substrate for an SBSE device. In this work, a novel SBSE device of SSW jacket-free stir bar with a dumbbell shape was designed and prepared. The conjugated microporous polymer CMP-F6, which possesses a porous structure, high hydrophobicity and rich fluorine-containing functional groups, was immobilized on the surface of SSW by the method of polyacrylonitrile glue adhesion. Compared with previous studies, which used SSW as a substrate, the method of etching partial SSW with hydrochloric acid, on the one hand, made the surface of SSW rough and easy to modify the extraction coating, and on the other hand, converted itself into a dumbbell-shaped structure, which is conducive to improving the extraction efficiency and stability of the SBSE device. The method of SBSE-HPLC-UV was established for determining five BUs. Owing to the hydrophobic interaction and F–F interaction between CMP-F6 and analytes, this method showed good extraction efficiency and had good linearity (R2 ≥ 0.9945) and high sensitivity (LODs in the range of 0.1–0.2 ng mL−1). It was used for the analysis of benzoylurea in an apple juice sample, and the recoveries were 74.3–117.9%.

Graphical abstract: Etched stainless steel wire modified with conjugated microporous polymers-F6 for jacket-free stir bar sorptive extraction of benzoylureas in juice sample

Supplementary files

Article information

Article type
Paper
Submitted
12 Apr 2024
Accepted
17 May 2024
First published
20 May 2024

Analyst, 2024,149, 3673-3680

Etched stainless steel wire modified with conjugated microporous polymers-F6 for jacket-free stir bar sorptive extraction of benzoylureas in juice sample

Z. Liu, Z. Hu, W. Hu, T. Ji and Z. Chen, Analyst, 2024, 149, 3673 DOI: 10.1039/D4AN00551A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements