Issue 4, 2023

High-precision measurement of Cd isotopes in ultra-trace Cd samples using double spike-standard addition MC-ICP-MS

Abstract

The double spike-standard addition (DSSA) is a powerful method proposed for isotope measurement of ultra-trace elements in samples. Here, we test the method's practicality and robustness for obtaining high-precision δ114/110Cd data in samples with complex matrices and ultra-trace cadmium (Cd) concentrations as low as 0.004 μg g−1. Through a DS data reduction routine and isotope binary mixing model, the δ114/110Cd values obtained for numeral geological and biological reference materials (GRMs/BRMs) agree well with certified or previous measurements, even for ∼2.1 ng Cd of BCR-2. The overall precision of both single- and multi-standard addition depends on the sample fraction (fspl) owing to the error propagation. And 0.041 ± 0.022‰ (2SD, n = 46) of precision for δ114/110Cd can be achieved when the sample fraction (fspl) is ≥20%, comparable to 0.056 ± 0.039‰ (2SD, n = 23) obtained by the traditional DS method. However, it becomes greater than 0.110‰ when fspl is <20%, indicating that 20% (1/5) −50% (1/2) of fspl is the optimal mixing range to obtain high-precision data if the minimal sample sizes are required. These further confirm that accurate and precise Cd isotope ratios can be determined by DSSA. Correspondingly, the purification scheme can be simplified to a single column due to the added standard solution boosting analyte and diluting ratios of matrix/Cd. Animal organs, with 0.004–0.106 μg g−1 Cd, yield large variations of δ114/110Cd (−0.054 ± 0.030‰ (2SD, n = 4) and 0.681 ± 0.022‰ (2SD, n = 4) for ovine liver and kidney, respectively), suggesting that Cd isotopes can be fractionated significantly during biological metabolic processes and may be a potential use in medical diagnosis. Robust measurement of Cd isotope composition in ultra-trace Cd samples with complex matrices by DSSA broadens the scope of measurable samples by the traditional DS method, thus potentially opening a range of new opportunities in life, agricultural, environmental, and earth/planetary sciences.

Graphical abstract: High-precision measurement of Cd isotopes in ultra-trace Cd samples using double spike-standard addition MC-ICP-MS

Associated articles

Supplementary files

Article information

Article type
Paper
Submitted
18 Feb 2023
Accepted
28 Feb 2023
First published
01 Mar 2023

J. Anal. At. Spectrom., 2023,38, 950-962

High-precision measurement of Cd isotopes in ultra-trace Cd samples using double spike-standard addition MC-ICP-MS

H. Chang, J. Zhu, X. Wang and T. Gao, J. Anal. At. Spectrom., 2023, 38, 950 DOI: 10.1039/D3JA00047H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements