Issue 19, 2021

Construction of a high fidelity epidermis-on-a-chip for scalable in vitro irritation evaluation

Abstract

3D skin equivalents have been increasingly used in the pharmaceutical and cosmetic industries, but the troublesome operation procedure and low throughput restricted their applications as in vitro safety evaluation models. Organ-on-a-chip, an emerging powerful tool in tissue/organ modeling, could be utilized to improve the function of the skin model compared with that of traditional static skin models, as well as innovate an automatic and modular way for construction or detection. In this research, we grew and differentiated human keratinocytes within a microfluidic chip to construct an integrated epidermis-on-a-chip (iEOC) system, which is specially designed to integrate multi-culture units with integrated bubble removal structures as well as trans-epithelial electrical resistance (TEER) electrodes for barrier function detection in situ. After 14 days of culture at the air–liquid interface (ALI), the constructed epidermis-on-a-chip demonstrated histological features similar to those observed in normal human epidermis: a proliferating basal layer and differentiating spinous, granular, and cornified layers, especially the TEER value reached 3 kΩ cm2 and prevented more than 99% of Cascade Blue-607 Da permeation owing to the enhanced barrier function. Further immunofluorescence analysis also indicated typical keratin expression including keratin-14, keratin-10, loricrin, involucrin, and filaggrin. With the TEER monitoring integration in the chip, it could be convenient for scale-up high-quality epidermis-on-chip fabrication and correlated investigation. Additionally, the iEOC can distinguish all the 10 known toxins and non-toxins in irritation measurement by MTT assay, which is consistent with animal testing according to the OECD. Preliminarily detection of irritation responses like inflammatory cytokines also predicted different irritation reactions. This high fidelity epidermis-on-a-chip could be a potential alternative in in vitro skin irritation evaluation. This microchip and automated microfluidic systems also pave the way for scalable testing in multidisciplinary industrial applications.

Graphical abstract: Construction of a high fidelity epidermis-on-a-chip for scalable in vitro irritation evaluation

Supplementary files

Article information

Article type
Paper
Submitted
06 Feb 2021
Accepted
02 Jul 2021
First published
12 Jul 2021

Lab Chip, 2021,21, 3804-3818

Construction of a high fidelity epidermis-on-a-chip for scalable in vitro irritation evaluation

J. Zhang, Z. Chen, Y. Zhang, X. Wang, J. Ouyang, J. Zhu, Y. Yan, X. Sun, F. Wang, X. Li, H. Ye, S. Sun, Q. Yu, J. Sun, J. Ge, Q. Li, Q. Han, Y. Pu and Z. Gu, Lab Chip, 2021, 21, 3804 DOI: 10.1039/D1LC00099C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements