Issue 18, 2020

Real-time monitoring and accurate diagnosis of drug-induced hepatotoxicity in vivo by ratio-fluorescence and photoacoustic imaging of peroxynitrite

Abstract

Because of the low tissue penetration depth and poor photostability of organic cyanine dye, in addition to environmental interference, it is a great challenge to monitor the degree of drug-induced hepatotoxicity by the in vivo detection of peroxynitrite (ONOO). Herein, we fabricated heptamethine cyanine dye (P-cy7)-coordinated upconversion nanoparticles (UCNPs), namely UCY7, as a fluorescent nanoprobe for evaluating drug-induced hepatotoxicity. Due to the luminescence resonance energy transfer (LRET) between UCNPs and the cyanine dye (P-cy7), the irradiation changed from visible light at 660 nm to near infrared (NIR) light at 980 nm; therefore, the issues of poor photostability and severe photobleaching of cyanine dye can be effectively solved. After injecting via the tail vein, the nanoprobes are rapidly concentrated in the liver. Since the level of ONOO is up-regulated during the drug-induced liver injury, the LRET between UCNPs and P-cy7 is disrupted to release the upconversion luminescence at 656 nm, while the upconversion luminescence at 800 nm remains constant, thus achieving the ratio-fluorescent imaging (RFLI) of ONOO in the liver to calibrate the influence of the environment. In addition, the reduction in the absorption of nanoprobes in the presence of ONOO allows for sensitive photoacoustic imaging (PAI). Based on the RFLI and PAI of the liver, the real-time monitoring and accurate diagnosis of different degrees of hepatotoxicity using the model of Acetaminophen (APAP) induction was achieved successfully, providing a new approach for the clinical evaluation of drug-induced hepatotoxicity.

Graphical abstract: Real-time monitoring and accurate diagnosis of drug-induced hepatotoxicity in vivo by ratio-fluorescence and photoacoustic imaging of peroxynitrite

Supplementary files

Article information

Article type
Paper
Submitted
04 Feb 2020
Accepted
05 Apr 2020
First published
13 Apr 2020

Nanoscale, 2020,12, 10216-10225

Real-time monitoring and accurate diagnosis of drug-induced hepatotoxicity in vivo by ratio-fluorescence and photoacoustic imaging of peroxynitrite

H. Zhuang, B. Li, M. Zhao, P. Wei, W. Yuan, M. Zhang, X. Han, Y. Chen and T. Yi, Nanoscale, 2020, 12, 10216 DOI: 10.1039/D0NR00963F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements