Jump to main content
Jump to site search
Access to RSC content Close the message box

Continue to access RSC content when you are not at your institution. Follow our step-by-step guide.


Issue 26, 2020
Previous Article Next Article

Self-assembled reduced graphene oxide–cerium oxide nanocomposite@cytochrome c hydrogel as a solid electrochemical reactive oxygen species detection platform

Author affiliations

Abstract

Monitoring of aberrant cellular levels of reactive oxygen species (ROS) has been a challenging task due to their shorter half-life and low concentration. Herein, a hybrid alginate–polyacrylamide hydrogel was prepared via an in situ self-assembly of reduced graphene oxide–cerium oxide nanocomposite (rGO–CeO2) and cytochrome c (Cyt c) and employed for electrochemical detection of ROS. The hydrogel platform, on one hand, provided a very large electroactive surface coverage and effectively increased the reactivity of Cyt c, and, on the other hand, integrated the rGO–CeO2 nanocomposite for enhancing electrochemical signals and structural stability. The formation of the rGO–CeO2@Cyt c hydrogel was confirmed through various microscopic and spectroscopic techniques. Besides, the electrochemical characteristics of rGO–CeO2@Cyt c hydrogel-modified screen-printed electrodes were investigated through cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. For the detection of ROS, CV and DPV measurements were carried out to monitor the concentration-dependent changes in current responses. The prepared sensor exhibited a selective and excellent linear response towards hydrogen peroxide (H2O2), hydroxyl radical (˙OH) and superoxide anion radical (O2˙) in the desired concentration range with detection limits of 0.166 μM, 0.338 μM and 0.229 μM, respectively. Taken together, these hybrid hydrogels based on electrochemical interfaces could be potential candidates for real time assessment of intracellular ROS levels, with implications for unraveling ROS-related disease mechanisms.

Graphical abstract: Self-assembled reduced graphene oxide–cerium oxide nanocomposite@cytochrome c hydrogel as a solid electrochemical reactive oxygen species detection platform

Back to tab navigation

Supplementary files

Article information


Submitted
23 Apr 2020
Accepted
09 Jun 2020
First published
11 Jun 2020

New J. Chem., 2020,44, 11248-11255
Article type
Paper

Self-assembled reduced graphene oxide–cerium oxide nanocomposite@cytochrome c hydrogel as a solid electrochemical reactive oxygen species detection platform

V. Kumar, A. Sachdev and I. Matai, New J. Chem., 2020, 44, 11248
DOI: 10.1039/D0NJ02038A

Social activity

Search articles by author

Spotlight

Advertisements