Jump to main content
Jump to site search
Access to RSC content Close the message box

Continue to access RSC content when you are not at your institution. Follow our step-by-step guide.


Issue 23, 2020
Previous Article Next Article

A real-time isothermal amplification based portable microfluidic system for simple and reliable detection of Vibrio splendidus

Author affiliations

Abstract

The spread of infectious diseases among aquaculture species has a serious impact on the aquaculture industry. Simple, specific and low-cost detection methods are urgently needed for early diagnosis and timely treatment, particularly for on-site identifying and tracking of pathogens. Vibrio splendidus (V. splendidus) is regarded as one of the main pathogenic bacteria causing skin ulcerative syndrome in cultured sea cucumbers, leading to massive mortality and severe economic losses. We herein present a microfluidic-based real-time fluorogenic loop-mediated isothermal amplification (LAMP) system for simple and reliable detection of V. splendidus. A LAMP primer set with six primers (arsB1) specifically targeting the arsB gene of V. splendidus was successfully designed and tested on the portable microfluidic system for the first time. Only a single step of sample loading using a pipette is required to fill an array of reaction wells (with 10 or 18 wells) in a disposable chip for multiplex detection. A dedicated plastic shell is then utilized to tightly seal the openings of the chip by buckling to prevent contamination and evaporation. Up to four chips (one sample per chip) can be held in the stand-alone and inexpensive microdevice simultaneously, enabling on-demand detection of multiple samples in a single run. Reproducible (relatively low intra- and inter-chip variability) and sensitive (as few as ∼20 CFU, Colony-Forming Units, per reaction well) on-chip arsB1-LAMP assay was demonstrated by using diluted lysate of V. splendidus. A linear standard curve (R2 > 0.98) was attained over the template concentration range of 5 × 103 to 5 × 106 CFU mL−1. V. splendidus can be detected in samples containing different bacteria, indicating the feasibility of the portable microfluidic LAMP system for parallel detection of multiple bacterial pathogens. The proposed on-chip LAMP assay is simple to operate, reliable for amplification, flexible in detection and cost-effective in instrumentation and testing, holding great potential for on-site rapid detection and routine monitoring of aquaculture pathogens.

Graphical abstract: A real-time isothermal amplification based portable microfluidic system for simple and reliable detection of Vibrio splendidus

Back to tab navigation

Article information


Submitted
18 Mar 2020
Accepted
12 May 2020
First published
15 May 2020

Anal. Methods, 2020,12, 2985-2994
Article type
Paper

A real-time isothermal amplification based portable microfluidic system for simple and reliable detection of Vibrio splendidus

R. Zhong, S. Liu, X. Wang, G. Zhang, N. Gong, M. Wang and Y. Sun, Anal. Methods, 2020, 12, 2985
DOI: 10.1039/D0AY00566E

Social activity

Search articles by author

Spotlight

Advertisements