Issue 22, 2020

Quantification of anthracene after dermal absorption test via APCI-tandem mass spectrometry

Abstract

An analytical method for the detection and quantification of anthracene from interstitial fluid samples was developed by using Atmospheric Pressure Chemical Ionization-Tandem Mass Spectrometry (APCI-MS/MS). The anthracene samples were obtained using intradermal microdialysis to assess dermal absorption of this polycyclic aromatic hydrocarbon (PAH). The experimental considerations were evaluated based on the chemical properties of this PAH and the detection limits of the instrumentation. The addition of an isotopically labeled internal standard allows the reduction of ionization suppression due to instrumental fluctuation and run-to-run deviation. The dermal extraction samples were prepared considering the proceeding conditions for measurement enhancement. Several variables for method validation including coefficient of determination (R2 = 0.993 ± 0.003), percent error (% error = 0 ± 2%), coefficient of variation (% CV = 5 ± 1%), lowest limit of detection (LOD = 39 ± 3 ng mL−1), and lowest limit of quantification (LLOQ = 129 ± 10 ng mL−1) were obtained from the inter- and intra-day measurements for the calibration and the quality control samples. Posterior to this, actual dermal interstitial fluid samples were measured, and it was observed they fitted into the ranges defined from the method development with good accuracy and precision. It was observed that the introduction of an internal standard while performing APCI-MS/MS allows an accurate and precise measurement of the concentration of anthracene to be obtained from dermal extraction samples. This method could be further used for complex mixtures to enhance our understanding of hazardous exposure of PAH on firefighter gear.

Graphical abstract: Quantification of anthracene after dermal absorption test via APCI-tandem mass spectrometry

Article information

Article type
Paper
Submitted
07 Mar 2020
Accepted
02 May 2020
First published
05 May 2020

Anal. Methods, 2020,12, 2820-2826

Quantification of anthracene after dermal absorption test via APCI-tandem mass spectrometry

X. Sui, J. E. Terán, C. Feng, K. Wustrow, C. J. Smith and N. R. Vinueza, Anal. Methods, 2020, 12, 2820 DOI: 10.1039/D0AY00486C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements