A new online pre-concentration system using hydride generation atomic fluorescence spectrometry (HG AFS) for zinc determination in mineral water and isotonic sports drinks

Author affiliations

Abstract

Mineral water and isotonic sports drinks (hydroelectrolytic supplement) are sources of electrolytes, and one among them is zinc, an important microelement for several functions of the body. In this study, a novel on-line preconcentration analytical method was developed and validated using atomic fluorescence spectrometry and chemical vapor generation to determine Zn, in mineral water and isotonic sports drinks employing multivariate optimization. The optimal parameters for the system were: pH = 8.00; [Na2CO3] = 6.5 × 10−3 mol L−1; sample flow = 5.70 mL min−1; flow rate = 8.00 mL min−1; and the elution flow rate was adjusted to 2.40 mL min−1 to obtain the analytical speed. The method to determine zinc in samples showed adequate linearity, repeatability and accuracy. The limits of detection (LOD) and quantification (LOQ) obtained for zinc were 0.03 and 0.09 μg L−1, respectively. Zinc concentration in mineral water and isotonic sports drinks ranged from 29.00 to 78.59 μg L−1. The enrichment factor (88.92) and sampling frequency/samples per hour (51) were obtained. Therefore, the results showed that the developed method is simple, fast, reliable, sensitive and selective for the determination of zinc in mineral water and isotonic sports drinks and can be applied in the control of the chemical and toxicological quality of these foods. Furthermore, the multivariate methodology using the complete factorial design and the Box–Behnken design was adequate for the optimization of the preconcentration system variables that influence the generation of the analytical signal.

Graphical abstract: A new online pre-concentration system using hydride generation atomic fluorescence spectrometry (HG AFS) for zinc determination in mineral water and isotonic sports drinks

Back to tab navigation

Article information


Submitted
22 Jan 2020
Accepted
20 Feb 2020
First published
10 Mar 2020

Anal. Methods, 2020,12, 1711-1719
Article type
Paper

A new online pre-concentration system using hydride generation atomic fluorescence spectrometry (HG AFS) for zinc determination in mineral water and isotonic sports drinks

M. A. Pitta da Costa, D. L. França da Silva, F. de Souza Dias, A. de Freitas Santos Júnior and W. N. Lopes dos Santos, Anal. Methods, 2020, 12, 1711