Inner filter effect based sensing system for the determination of caffeine in beverages samples.

Abstract

In this work, the inner filter effect (IFE) of caffeine (CF) over the fluorescence signal of glibenclamide (GLB) was used for the determination of CF in beverages samples. The system worked in a turn-off mode since the absorption spectrum of CF overlaps the excitation band of GLB resulting in a decline on its fluorescence signal (λexc= 234 nm, λem=350 nm). No changes in the fluorescence lifetime of GLB (0.29 ns) were observed in the presence of CF up to 127.6 mg L-1 concentration. The parameters that affect the fluorescence intensity were investigated, such as fluorophore concentration (16 mg L-1), pH (3.2) and temperature (25ºC). Under optimized conditions, the IFE-based approach can determine CF in a range between 1.00 and 100.0 mg L-1, with a detection limit (LOD) of 0.10 mg L-1. The relative standard deviation (% RSD) values for the intra-day and inter-day precision were 0.75 and 1.24, respectively. The new method was successfully tested in the determination of the target analyte in beverages samples without previous treatment. The results were compared with those obtained by a reference method, concluding that there were no significant differences at the studied confidence level (α=0.05).

Back to tab navigation

Supplementary files

Article information


Accepted
01 Jan 2020
First published
03 Jan 2020

Analyst, 2020, Accepted Manuscript
Article type
Paper

Inner filter effect based sensing system for the determination of caffeine in beverages samples.

N. González, S. Lantmann Corral, G. P. Zanini, H. A. Montejano and C. Acebal, Analyst, 2020, Accepted Manuscript , DOI: 10.1039/C9AN02483B

Social activity

Search articles by author

Spotlight

Advertisements