Issue 47, 2019

Development of a nickel oxide/oxyhydroxide-modified printed carbon electrode as an all solid-state sensor for potentiometric phosphate detection

Abstract

Phosphate is one of the main nutrients playing many key roles in the human body and plant growth. Because of this essential demand, phosphate is often used as a micronutrient additive in both fertilizers and dietary supplements. However, its excessive amount could result in severe health issues in the human body and the ecosystem of aquatic life. Therefore, there is a need for an inexpensive rapid measurement approach that could assess the optimum level of phosphate by using simple low-cost sensors. Here, for the first time, we demonstrate the use of a nickel oxide modified screen printed carbon (PrC) electrode as a low-cost electrochemical potentiometric phosphate detection sensor. The nickel oxide/oxyhydroxide (NiO/NiOOH)-PrC electrode has been prepared by a facile anodic electrodeposition process onto a screen printed carbon electrode. The characterization performed by field emission scanning electron microscopy (FE-SEM) and energy diffractive X-ray spectroscopy (EDS) techniques confirmed the formation of NiO/NiOOH by significant changes in surface morphology and elemental composition of PrC after electrodeposition. The results exhibited a porous deposited layer containing nickel and an increased oxygen value of the modified electrode as compared to pristine PrC. Potentiometric phosphate detection on the NiO/NiOOH-PrC electrode showed a linear response in the concentration range of 10−6–10−1 M, yielding a slope of −78.48 mV per decade with a fast response time. The electrode demonstrated a stable response with less than 0.8% variability of the recorded potential over 2000 seconds. High durability and reusability of the electrode were confirmed by repeated potentiometric phosphate determination tests over a course of 21 days. Interference tests with chloride, nitrate, sulfate, bromide, acetate, and carbonate solutions revealed very low selectivity coefficients within the range of 10−11–10−2, which indicated a high phosphate-selectivity of the developed sensor. This novel technology provides great potential for future scalable production and applications in portable real-time monitoring of phosphate ions in different precision agricultural and point-of-care diagnostic applications.

Graphical abstract: Development of a nickel oxide/oxyhydroxide-modified printed carbon electrode as an all solid-state sensor for potentiometric phosphate detection

Supplementary files

Article information

Article type
Paper
Submitted
02 Sep 2019
Accepted
22 Oct 2019
First published
24 Oct 2019

New J. Chem., 2019,43, 18619-18628

Development of a nickel oxide/oxyhydroxide-modified printed carbon electrode as an all solid-state sensor for potentiometric phosphate detection

S. Sedaghat, S. Jeong, A. Zareei, S. Peana, N. Glassmaker and R. Rahimi, New J. Chem., 2019, 43, 18619 DOI: 10.1039/C9NJ04502C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements