Accurate analysis of Li isotopes in tourmalines by LA-MC-ICP-MS under “wet” conditions with non-matrix-matched calibration

Author affiliations

Abstract

The Li isotopic compositions of tourmalines can be used as a powerful geochemical tracer and provide valuable information regarding magma–volatile relationships and the magmatic-hydrothermal evolution of pegmatites. Laser ablation-multiple collector-inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) is the method of choice for in situ Li isotopic analysis. In this study, we investigated the feasibility of Li isotopic analysis in tourmalines by both ns- and fs-LA-MC-ICP-MS with (tourmalines as calibration standards) and without (NIST 610 glass as the calibration standard) matrix-matched calibration. The Li isotopes of tourmalines can be accurately analyzed with matrix-matched calibration by ns- or fs-LA-MC-ICP-MS. However, inaccurate δ7Li values were obtained when tourmalines were measured against a non-matrix-matched standard by ns- (∼10.0‰ deviation) and fs-LA-MC-ICP-MS (∼1.5‰ deviation). Wet plasma conditions can significantly reduce the matrix effect in isotopic analysis. Furthermore, the deviation in fs-LA-MC-ICP-MS can be suppressed by water addition after the ablation cell. However, a relatively large deviation (∼4‰) still existed, even though the matrix effect during ns-LA can be largely suppressed by water addition after the ablation cell (∼6‰ deviation was reduced). Fortunately, with the water addition before the ablation cell, an accurate and precise Li isotopic analysis by ns-LA-MC-ICP-MS can be achieved with non-matrix-matched calibration. This study indicated that there was a serious matrix effect in the Li isotopic analysis of tourmalines by ns- and fs-LA-MC-ICP-MS, and water-assisted ns- and fs-LA-MC-ICP-MS were an appealing option for the in situ Li isotope analysis of tourmaline with non-matrix-matched calibration.

Graphical abstract: Accurate analysis of Li isotopes in tourmalines by LA-MC-ICP-MS under “wet” conditions with non-matrix-matched calibration

Back to tab navigation

Supplementary files

Publication details

The article was received on 15 Jan 2019, accepted on 05 Mar 2019 and first published on 06 Mar 2019


Article type: Paper
DOI: 10.1039/C9JA00013E
Citation: J. Anal. At. Spectrom., 2019, Advance Article

  •   Request permissions

    Accurate analysis of Li isotopes in tourmalines by LA-MC-ICP-MS under “wet” conditions with non-matrix-matched calibration

    J. Lin, Y. Liu, Z. Hu, W. Chen, C. Zhang, K. Zhao and X. Jin, J. Anal. At. Spectrom., 2019, Advance Article , DOI: 10.1039/C9JA00013E

Search articles by author

Spotlight

Advertisements