Quantitative analysis of chromium in pork by PSO-SVM chemometrics based on laser induced breakdown spectroscopy

Abstract

In order to improve the stability and prediction accuracy of a Laser Induced Breakdown Spectroscopy (LIBS) quantitative analysis model a chemometrics method named PSO-SVM (particle swarm optimization-support vector machine) is proposed for the quantitative prediction of heavy metal chromium (Cr) in pork by analyzing the spectral data obtained by LIBS. The usable spectral region from 424.77 to 429.99 nm was identified. The normalized preprocessing of spectra was employed. Also, the spectral dimension was reduced through principal component analysis (PCA). The PSO algorithm was applied to select the SVM hyper-parameters including the regularization and kernel parameters. The calibration model of heavy metal Cr in pork was established using the optimum hyper-parameters obtained by PSO-SVM. The performance of this PSO-SVM model was compared with a synergy interval partial least squares (siPLS) model and a multilayer perceptron artificial neural network (MLP-ANN). The feasibility of these three methods was examined on the test sample set. The experimental results showed that the proposed method (PSO-SVM) achieved better prediction accuracy robustness compared with the other two quantitative analysis methods. The calibration results of siPLS and MLP-ANN models are similar, and the fitting degree of the siPLS modeling effect is not high, while the MLP-ANN verification results are not ideal. For the PSO-SVM model, the correlation coefficients (R2) of the calibration and validation sets were higher than 0.99. The mean absolute percentage error (MAPE) of the calibration set is 0.0792%, and the MAPE of the validation set is 1.9395%. The RMSE values of the calibration and validation sets were 0.0245% and 0.6961%, respectively, which were much lower than the other two models. This investigation displayed that the PSO-SVM algorithm exhibited excellent model robustness and prediction accuracy. There is definite practical significance and application value in the monitoring of meat safety by analyzing LIBS data coupled with PSO-SVM methods.

Graphical abstract: Quantitative analysis of chromium in pork by PSO-SVM chemometrics based on laser induced breakdown spectroscopy

Article information

Article type
Paper
Submitted
14 Nov 2018
Accepted
25 Jan 2019
First published
25 Jan 2019

J. Anal. At. Spectrom., 2019,34, 884-890

Quantitative analysis of chromium in pork by PSO-SVM chemometrics based on laser induced breakdown spectroscopy

T. Chen, L. Zhang, L. Huang, M. Liu, J. Chen and M. Yao, J. Anal. At. Spectrom., 2019, 34, 884 DOI: 10.1039/C8JA00392K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements