High-precision measurements of krypton and xenon isotopes with a new static-mode quadrupole ion trap mass spectrometer

Abstract

Measuring the abundance and isotopic composition of noble gases in planetary atmospheres can answer fundamental questions in cosmochemistry and comparative planetology. However, noble gases are rare elements, a feature making their measurement challenging even on Earth. Furthermore, in space applications, power consumption, volume and mass constraints on spacecraft instrument accommodations require the development of compact innovative instruments able to meet the engineering requirements of the mission while still meeting the science requirements. Here we demonstrate the ability of the quadrupole ion trap mass spectrometer (QITMS) developed at the Jet Propulsion Laboratory (Caltech, Pasadena) to measure low quantities of heavy noble gases (Kr, Xe) in static operating mode and in the absence of a buffer gas such as helium. The sensitivity reaches 1013 cps Torr−1 (about 1011 cps Pa−1) of gas (Kr or Xe). The instrument is able to measure gas in static mode for extended periods of time (up to 48 h) enabling the acquisition of thousands of isotope ratios per measurement. Errors on isotope ratios follow predictions of the counting statistics and the instrument provides reproducible results over several days of measurements. For example, 1.7 × 10−10 Torr (2.3 × 10−8 Pa) of Kr measured continuously for 7 hours yielded a 0.6‰ precision on the 86Kr/84Kr ratio. Measurements of terrestrial and extraterrestrial samples reproduce values from the literature. A compact instrument based upon the QITMS design would have a sensitivity high enough to reach the precision on isotope ratios (e.g. better than 1% for 129,131–136Xe/130Xe ratios) necessary for a scientific payload measuring noble gases collected in the Venus atmosphere.

Graphical abstract: High-precision measurements of krypton and xenon isotopes with a new static-mode quadrupole ion trap mass spectrometer

Article information

Article type
Paper
Submitted
27 Jun 2018
Accepted
23 Oct 2018
First published
23 Oct 2018

J. Anal. At. Spectrom., 2019,34, 104-117

High-precision measurements of krypton and xenon isotopes with a new static-mode quadrupole ion trap mass spectrometer

G. Avice, A. Belousov, K. A. Farley, S. M. Madzunkov, J. Simcic, D. Nikolić, M. R. Darrach and C. Sotin, J. Anal. At. Spectrom., 2019, 34, 104 DOI: 10.1039/C8JA00218E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements