Jump to main content
Jump to site search


Metal Salt Assisted Electrospray Mass Spectrometry for Soft Ionization of GAP Polymers in Negative Ion Mode

Abstract

Glycidyl azide polymers (GAP) are one of the most important energetic polymers, but it is still a challenge to elucidate their structures using mass spectrometry due to its fragileness upon ionization. Herein we develop a soft metal salt assisted electrospray ionization (MSAESI) to characterize directly GAP polymers using mass spectrometry. This technique combines paper spray ionization and the complexing effect of anions from metal salts with GAP in a negative ion mode to softly ionize GAP polymers prior to mass spectrometric analysis. The effects of experimental parameters (e.g., ion mode, applied voltage, and type and concentration of metal salts) have been investigated in detail. In contrast to the positive ion mode, a softer ionization was observed for GAP polymer when negative ion mode was applied. The radius and average charge of cations and anions in metal salts were found to play crucial roles in determining the performance of a MSAESI analysis of GAP. For a given charge number, a smaller radius of cations favored to a soft ionization of GAP polymers (e.g., Na+ > K+ > Rb+), whereas a larger radius of anions led to a preferred performance (e.g., F- < Cl- < Br- < I-) due to variation in dissolution ability. For anions with multiple charges, the ones with fewer charges gave a more favorable ionization to GAP sample because of its better complexing to GAP molecules than those with more charges in the structure of anions (e.g., NO3- > SO42- > PO43-). According to the experimental observation and evidences from mass spectrometry, we proposed the plausible electrospray mechanisms of MSAESI for GAP analysis with involvement of metal salts. Moreover, the developed protocol has been applied successfully to analysis of various GAP samples, and works to other types of sources such as nanoelectrospray ionization.

Back to tab navigation

Supplementary files

Publication details

The article was received on 23 Sep 2019, accepted on 30 Oct 2019 and first published on 30 Oct 2019


Article type: Paper
DOI: 10.1039/C9AN01887E
Analyst, 2019, Accepted Manuscript

  •   Request permissions

    Metal Salt Assisted Electrospray Mass Spectrometry for Soft Ionization of GAP Polymers in Negative Ion Mode

    T. Muyizere, Y. Zheng, H. Liu, J. Zhao, J. Li, X. Lu, D. Austin and Z. Zhang, Analyst, 2019, Accepted Manuscript , DOI: 10.1039/C9AN01887E

Search articles by author

Spotlight

Advertisements