Jump to main content
Jump to site search
Access to RSC content Close the message box

Continue to access RSC content when you are not at your institution. Follow our step-by-step guide.


Issue 14, 2019
Previous Article Next Article

Electronically-tuned triarylmethine scaffolds for fast and continuous monitoring of H2S levels in biological samples

Author affiliations

Abstract

A sensor for the detection and quantification of H2S in biological samples should ideally meet a set of criteria such as fast detection, high sensitivity in the desired concentration range, high selectivity, non-interference from biomolecules like proteins, ease of synthesis, long-term stability and water solubility. Although a number of H2S probes are known, none of them possess all the above attributes that are relevant for practical applications. As part of a program to develop reliable chemical probes for continuous monitoring of this gasotransmitter in the blood plasma of sepsis-prone individuals in post-operative wards, we have looked at the possibility of improving the reactivity and selectivity profile of triarylmethine dyes towards different nucleophiles. After achieving high sensitivity through electronic control, the interference from sulfite, thiosulfate and metabisulfite was addressed by introducing a metal salt-mediated desulfuration step that results in dye regeneration selectively from its H2S adduct. Typically, if the analyte contains only H2S, the loss of absorbance in the first step gets completely reinstated after the second step; absorbance changes in both steps vary linearly with sulfide concentration and either of these two steps can be used for the quantification of H2S with the help of standard plots. In the presence of interfering ions, the first step will show decolourization due to the presence of all of them whereas only the H2S-adduct will undergo desulfuration in the second step which can be used for quantification. The decolourization step is instantaneous while the desulfuration requires only about 50 s, making the entire protocol complete in less than a minute. The methodology optimized here also meets the requirements mentioned above for real-life applications.

Graphical abstract: Electronically-tuned triarylmethine scaffolds for fast and continuous monitoring of H2S levels in biological samples

Back to tab navigation

Supplementary files

Article information


Submitted
20 Mar 2019
Accepted
24 May 2019
First published
28 May 2019

Analyst, 2019,144, 4210-4218
Article type
Paper

Electronically-tuned triarylmethine scaffolds for fast and continuous monitoring of H2S levels in biological samples

R. Kalluruttimmal, D. Thekke Thattariyil, A. Panthalattu Parambil, A. K. Sen, L. Chakkumkumarath and M. K. Manheri, Analyst, 2019, 144, 4210
DOI: 10.1039/C9AN00522F

Social activity

Search articles by author

Spotlight

Advertisements