Abstract

Human cytomegalovirus (hCMV) infection is the leading cause of birth defects in newborns and death in immunosuppressed people. Traditional techniques require time-consuming and costly analyses, and sometimes result in false positive results; thus, a rapid and accurate detection for hCMV infection is necessary. Recently, hcmv-miR-US4-5p was selected as the biomarker for cytomegalovirus diagnosis and follow-up. Herein, we propose a bioassay based on microgels endowed with optical fluorescent oligonucleotide probes for the detection of circulating endogenous hcmv-microRNAs. In particular, a double strand probe, based on the fluorescence recovery after target capture, was conjugated on microgels and the probe density was opportunely optimised. Then, the microgels were directly mixed with the sample. The fluorescence read-out was measured as a function of target concentration at a fixed number of microgels per tube. As a bead-based assay, the performances of optical detection in terms of dynamic working range and limit of detection could be finely tuned by tuning the number of microgels per tube. The limit of detection of the assay could be tuned in the range from 39.1 fM to 156 aM by changing the microgel concentration from 50 μg mL−1 to 0.5 μg mL−1, respectively. The assay results specific for the selected target were stable over a one-year time span and they were not affected by the presence of human serum. Therefore, this bioassay based on microgels might represent a flexible platform that should be able to predict, identify and follow-up several diseases by monitoring freely circulating oligonucleotides in body fluids.

Graphical abstract: One-step scalable fluorescent microgel bioassay for the ultrasensitive detection of endogenous viral miR-US4-5p

Supplementary files

Article information

Article type
Paper
Submitted
09 Nov 2018
Accepted
05 Dec 2018
First published
06 Dec 2018

Analyst, 2019,144, 1369-1378

One-step scalable fluorescent microgel bioassay for the ultrasensitive detection of endogenous viral miR-US4-5p

T. M. Caputo, A. Cummaro, V. Lettera, A. Mazzarotta, E. Battista, P. A. Netti and F. Causa, Analyst, 2019, 144, 1369 DOI: 10.1039/C8AN02166J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements