Jump to main content
Jump to site search
PLANNED MAINTENANCE Close the message box

Scheduled maintenance work on Wednesday 22nd May 2019 from 11:00 AM to 1:00 PM (GMT).

During this time our website performance may be temporarily affected. We apologise for any inconvenience this might cause and thank you for your patience.


Issue 27, 2018
Previous Article Next Article

An early fire sensor based on infrared gas analytical methods

Author affiliations

Abstract

Fire is the rapid oxidation reaction of a material in the chemical process of combustion, which releases heat, light, and various reaction products. Fires account for huge numbers of casualties and economic losses each year in spite of the widespread use of fire sensors. In comparison to traditional smoke or temperature-based analytical methods, the gas sensor-based methods are more effective since gases are produced in every fire while not all fires emit smoke aerosols during the combustion process, and the changes of ambient temperature in the early stage of a fire are too small to be sensed. Among the fire gases, carbon monoxide (CO), which has trace concentration levels (down to 0.1 parts per million by volume (ppmv)) in ambient air but is produced at high levels (up to vol%) in smoldering fires, is a promising gas for early fire detection. In this study, a laser-based sensor has been developed for the high precision and highly sensitive measurement of CO produced by fires. The sensor relies on a continuous wave (CW), distributed feedback (DFB) laser emitting at ∼2.33 μm as the excitation source. A wavelength modulation spectroscopy (WMS)-2f/WMS-1f strategy was adopted to isolate complex, overlapping spectral absorption features at ambient pressures and to achieve excellent specificity and high detection sensitivity. The long-term performance of the sensor system was evaluated by the Allan–Werle deviation analysis. The results showed that the limit of detection (LoD) and the optimal integration time are 1.18 ppmv and ∼205 s (corresponding to a measurement precision of ∼0.08 ppmv on average), respectively. As a field application, our sensor was used for the early detection of fires from paper, cotton and pine wood, which verified its reliable and robust operation.

Graphical abstract: An early fire sensor based on infrared gas analytical methods

Back to tab navigation

Publication details

The article was received on 19 Mar 2018, accepted on 15 Jun 2018 and first published on 18 Jun 2018


Article type: Paper
DOI: 10.1039/C8AY00591E
Anal. Methods, 2018,10, 3325-3331

  •   Request permissions

    An early fire sensor based on infrared gas analytical methods

    J. Dang, H. Yu, C. Zheng, Y. Wang and Y. Sun, Anal. Methods, 2018, 10, 3325
    DOI: 10.1039/C8AY00591E

Search articles by author

Spotlight

Advertisements