Issue 17, 2018

Pre-concentration and determination of cadmium and lead ions in real water, soil and food samples using a simple and sensitive green solvent-based ultrasonic assisted dispersive liquid–liquid microextraction and graphite furnace atomic absorption spectrometry

Abstract

A novel green solvent-based ultrasonic assisted dispersive liquid–liquid microextraction (GS-UADLLME) method was developed for the preconcentration of cadmium and lead ions in various real samples prior to determination by graphite furnace atomic absorption spectrometry (GFAAS). In order to extract trace amounts of cadmium and lead ions, 2-amino-3-sulfhydrylpropanoic acid (L-cysteine) (as a green ligand), tetrafluoroborate ion (BF4) (as an ion pair agent) and 1-butyl-3-methylimidazolium tetrafluoroborate [BMIM][BF4] (as acceptor phase) were used. Different effective factors in the microextraction procedure such as pH of the sample solution, sample solution volume, acceptor phase volume, L-cysteine and tetrafluoroborate concentrations, centrifugation conditions and salting addition were thoroughly optimized. Under the optimum conditions, the calibration graphs were linear in the range of 0.8–180 and 2.5–190 ng L−1 with a correlation coefficient (r2) higher than 0.9967 for the measurement of cadmium and lead ions, respectively. The limits of detection for the determination of Cd(II) and Pb(II) for the proposed method were 0.2 and 0.7 ng L−1, respectively. The relative standard deviations (n = 5) for the analyte determination were lower than 3.4%. In order to investigate the method’s accuracy, cadmium and lead contents of a certified reference material, SRM 1643e (NIST), were determined and the results from the proposed method were in very good agreement with the certified values. The suggested method was successfully applied to the determination of cadmium and lead ions in real samples such as real water, soil, rice and tea samples.

Graphical abstract: Pre-concentration and determination of cadmium and lead ions in real water, soil and food samples using a simple and sensitive green solvent-based ultrasonic assisted dispersive liquid–liquid microextraction and graphite furnace atomic absorption spectrometry

Article information

Article type
Paper
Submitted
22 Feb 2018
Accepted
08 Apr 2018
First published
23 Apr 2018

Anal. Methods, 2018,10, 2041-2047

Pre-concentration and determination of cadmium and lead ions in real water, soil and food samples using a simple and sensitive green solvent-based ultrasonic assisted dispersive liquid–liquid microextraction and graphite furnace atomic absorption spectrometry

M. Ghorbani, S. Akbarzade, M. Aghamohammadhasan, O. Seyedin and N. Afshar Lahoori, Anal. Methods, 2018, 10, 2041 DOI: 10.1039/C8AY00398J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements