Jump to main content
Jump to site search

Issue 19, 2018
Previous Article Next Article

An up-converting phosphor technology-based lateral flow assay for point-of-collection detection of morphine and methamphetamine in saliva

Author affiliations

Abstract

Morphine (Mop) and methamphetamine (Met) are highly addictive drugs worldwide. Point-of-collection testing (POCT) for drug-of-abuse screening is important in abuse/rehabilitation clinics and law-enforcement agencies. We established an up-converting phosphor technology-based lateral flow assay (UPT-LFA) as a point-of-collection testing (POCT) method, namely Mop-UPT-LFA and Met-UPT-LFA, for the detection of morphine and methamphetamine without complicated sample pre-treatment, respectively, in saliva. The sensitivities of the Mop-UPT-LFA and the Met-UPT-LFA were 5 and 10 ng mL−1 with accurate quantitation of 5–100 ng mL−1 and 10–250 ng mL−1 for morphine and methamphetamine, respectively, for a detection time of 15 min. In reference to the detection limits of 20 and 25 ng mL−1 for morphine and methamphetamine, respectively, in the Driving Under the Influence of Drugs, Alcohol and Medicines (DRUID) program of the European Union, the percentage test/control (T/C) ratio of the UPT-LFA between 2 and 15 min reached 101% and 86%, and the UPT-LFA produced accurate qualitative results in 2 min for 100 simulated-saliva samples with the exception of a few weakly positive samples. The sample and sample treating buffer were mixed and added to the test strip, and the test was conducted 15 min later. Although we found no significant difference between the UPT-LFA quantitative test and the liquid chromatography tandem mass spectrometry (LC-MS) test, compared with the latter, the UPT-LFA was substantially faster and had higher detection efficiency. The UPT-LFA showed more accurate qualitative results than the LC-MS for 50 simulated-saliva samples. The ease of operation, high sensitivity, and accuracy of the UPT-LFA make it a valid candidate POCT method for drug-of-abuse screening.

Graphical abstract: An up-converting phosphor technology-based lateral flow assay for point-of-collection detection of morphine and methamphetamine in saliva

Back to tab navigation

Supplementary files

Publication details

The article was received on 10 Apr 2018, accepted on 30 Jul 2018 and first published on 01 Aug 2018


Article type: Paper
DOI: 10.1039/C8AN00651B
Citation: Analyst, 2018,143, 4646-4654
  •   Request permissions

    An up-converting phosphor technology-based lateral flow assay for point-of-collection detection of morphine and methamphetamine in saliva

    Q. Hu, Q. Wei, P. Zhang, S. Li, L. Xue, R. Yang, C. Wang and L. Zhou, Analyst, 2018, 143, 4646
    DOI: 10.1039/C8AN00651B

Search articles by author

Spotlight

Advertisements