Issue 8, 2018

In situ formation of SERS hot spots by a bis-quaternized perylene dye: a simple strategy for highly sensitive detection of heparin over a wide concentration range

Abstract

A simple and ultrasensitive surface-enhanced Raman scattering (SERS) assay for heparin detection has been demonstrated based on an in situ hot spot assembly method using N,N′-bis[3,3′-(trimethylammonium)propylamine]-3,4,9,10-perylenediimide (bis-quaternized perylene dye, abbreviated as BQPER). In this assay, a BQPER probe with two positive charges is employed as both Raman reporter and electrostatic bridge to cause the aggregation of citrate-capped Ag nanoparticles (Ag NPs), resulting in a strong SERS signal due to the formation of numerous hot spots in the gaps of the aggregates. The SERS intensity of BQPER decreases in the presence of heparin, because BQPER binds primarily to heparin due to its high anionic charge to mass ratio compared to that of Ag NPs. Accordingly, a novel method for the detection of heparin has been developed based on SERS of the unbound BQPER probe. Two obvious advantages of the proposed heparin assay over other reported methods are: its much wider linear concentration range (10−5–10−10 g mL−1) and lower limit of detection (0.08 ng mL−1). Besides, our proposed heparin assay has been successfully applied to the detection of heparin in serum samples, indicating its great potential in the diagnosis of heparin-related diseases. This work provides a new Raman probe for the SERS analysis of heparin and opens a different perspective for SERS-based transducer design in charged analytes.

Graphical abstract: In situ formation of SERS hot spots by a bis-quaternized perylene dye: a simple strategy for highly sensitive detection of heparin over a wide concentration range

Supplementary files

Article information

Article type
Paper
Submitted
04 Jan 2018
Accepted
28 Feb 2018
First published
03 Mar 2018

Analyst, 2018,143, 1899-1905

In situ formation of SERS hot spots by a bis-quaternized perylene dye: a simple strategy for highly sensitive detection of heparin over a wide concentration range

W. Ji, X. Zhang, J. Zhao, Y. Gao, W. Song and Y. Ozaki, Analyst, 2018, 143, 1899 DOI: 10.1039/C8AN00015H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements