Issue 42, 2017

Preparation of a novel RAM-MIP for selective solid-phase extraction and gas chromatography determination of heptachlor, endosulfan and their metabolite residues in pork

Abstract

A novel method was established using a restricted access material combined with a molecularly imprinted polymer (RAM-MIP) as the sorbent material in solid phase extraction (SPE) for clean-up of α-endosulfan, β-endosulfan, endosulfate, endosulfan-ether, endosulfan lactone, heptachlor, heptachlor-exo-epoxide, and heptachlor-endo-epoxide in pork and gas chromatography (GC) for determination. The RAM-MIP was prepared by precipitation polymerization by using endosulfan as the template, methacrylic acid (MAA) as the monomer, glycidyl methacrylate (GMA) as the pro-hydrophilic co-monomer, ethylene glycol dimethacrylate (EGDMA) as the crosslinker, azobisisobutyronitrile (AIBN) as the initiator, and toluene as the porogen. Ultraviolet spectroscopy (UV) and 1H-nuclear magnetic resonance (1H-NMR) analysis verified that MAA interacted specifically with endosulfan in a ratio of 1 : 1 in the pre-polymerization solution. The RAM-MIP exhibited specific adsorption performance for endosulfan and efficiently avoided the deposition of macromolecules on the surface of polymers. The residues of endosulfan, heptachlor and their metabolites in pork were extracted with acetone : n-hexane (2 : 8, v/v), cleaned up by using a SPE cartridge packed with the RAM-MIP, and determined by GC. The limits of quantification (LOQs) for endosulfan, heptachlor and their metabolites in pork samples were confined to 0.005 mg kg−1. The recoveries of target compounds spiked at 0.005–0.05 mg kg−1 were 51.17–107.73% with relative standard deviations (RSDs) of 1.4–15.9%. Thus, this novel method can be successfully applied to the determination of heptachlor, endosulfate and their metabolite residues in pork samples.

Graphical abstract: Preparation of a novel RAM-MIP for selective solid-phase extraction and gas chromatography determination of heptachlor, endosulfan and their metabolite residues in pork

Supplementary files

Article information

Article type
Paper
Submitted
09 Aug 2017
Accepted
26 Sep 2017
First published
27 Sep 2017

Anal. Methods, 2017,9, 6009-6018

Preparation of a novel RAM-MIP for selective solid-phase extraction and gas chromatography determination of heptachlor, endosulfan and their metabolite residues in pork

H. G. Zuo, H. Yang, J. X. Zhu and Y. Ding, Anal. Methods, 2017, 9, 6009 DOI: 10.1039/C7AY01941F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements