Enzymatic electrochemical biosensor for urea with a polyaniline grafted conducting hydrogel composite modified electrode

Abstract

Conducting polymer hydrogels (CPH) are a unique class of materials, which have both the advantageous features of hydrogels and organic conductors. Herein, we report a new urea biosensor in which the working electrode is modified by a CPH, specifically a composite made of conducting electro-polymerized aniline in the non-conducting hydrogel of polyacrylamide and polyvinyl alcohol for immobilization of the enzyme urease. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) studies depict the porous structure of the hydrogel, which favours the high density immobilization of enzymes. Fourier transform infrared spectroscopy (FTIR) studies confirmed the grafting of polyaniline within the matrix. Electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV) and cyclic voltammetry (CV) predict high enzyme loading in the hydrogel. Bode plot analysis with the [FeCN6]3−/4− redox couple shows the partial capacitive behaviour of the bioelectrode in the frequency range of 102 to 103 Hz. Factors, such as scan rate and pH of the electrolyte, were optimized to give the best results. DPV could detect 1.5–1000 μM urea with the lowest detection limit (LOD) of 60 nM and sensitivity of 878 μA mM−1 cm−2. The relatively low Michaelis–Menten constant (Km) value of 113 μM indicates the high affinity of the enzyme for urea. EIS depicts an increase in charge transfer resistance (RCT) with an increase in urea concentration (LOD = 14 μM). The proposed sensor exhibits a very good performance with respect to detection limit, sensitivity, Km value, preparation method, cost, sample preparation, stability, selectivity and reproducibility. This sensor was successfully applied for the detection of urea in milk, puffed rice, soil and human blood. Statistical analysis of the results shows good agreement with commercial spectrophotometric analysis.

Graphical abstract: Enzymatic electrochemical biosensor for urea with a polyaniline grafted conducting hydrogel composite modified electrode

Supplementary files

Article information

Article type
Paper
Submitted
10 May 2016
Accepted
29 Aug 2016
First published
07 Sep 2016

RSC Adv., 2016,6, 92520-92533

Enzymatic electrochemical biosensor for urea with a polyaniline grafted conducting hydrogel composite modified electrode

J. Das and P. Sarkar, RSC Adv., 2016, 6, 92520 DOI: 10.1039/C6RA12159D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements