Issue 21, 2016

Asymmetric immobilization of antibodies on a piezo-resistive micro-cantilever surface

Abstract

For cantilever-based MEMS sensors, selective chemical modification of the sensing surface is used for the detection of chemical and biological analytes. One of the key challenges in these kind of applications is to obtain an increased level of sensitivity, which largely depends on the surface coverage of the respective probe molecules on one of the cantilever surfaces (asymmetric immobilization). Usually, a blocking layer of another material like gold is deposited on one side of the cantilever surface to obtain layers with different chemical properties. In this paper, we report a novel approach of grafting antibodies on a single side of micro-fabricated piezo-resistive cantilevers. The microcantilevers were fabricated with polysilicon as the piezo-resistive layer, sandwiched between silicon dioxide structural layers. In order to immobilize antibodies on one of the cantilever surfaces (top or bottom), a thin layer of amorphous silicon was deposited on the surface where immobilization needs to be done. This amorphous silicon layer was partially modified into silicon nitride by a Hot-Wire Chemical Vapour Deposition (HWCVD) mediated pyrolytic ammonia-cracking process. The developed selective surface modification protocol for nitride and silicon dioxide surface was studied using X-ray photoelectron spectroscopy (XPS), ellipsometry and contact-angle goniometry. The protocol was first developed on silicon wafer surface, further extending its application onto the piezo-resistive micro-cantilevers. Consequentially, asymmetric immobilization was successfully carried out by selectively grafting antibodies onto the top (modified into nitride) surface of the micro-cantilever by passivating the bottom oxide surface. It was verified using fluorescence microscopy and laser confocal microscopy. Further, we have demonstrated that asymmetrically modified cantilevers show an increased electrical response (20–100%) in comparison to symmetrically modified ones.

Graphical abstract: Asymmetric immobilization of antibodies on a piezo-resistive micro-cantilever surface

Supplementary files

Article information

Article type
Paper
Submitted
17 Jan 2016
Accepted
02 Feb 2016
First published
03 Feb 2016

RSC Adv., 2016,6, 17606-17616

Asymmetric immobilization of antibodies on a piezo-resistive micro-cantilever surface

D. K. Agarwal, N. Maheshwari, S. Mukherji and V. R. Rao, RSC Adv., 2016, 6, 17606 DOI: 10.1039/C6RA01440B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements