Abstract

The current study is focused on the determination of the trace levels of manganese, zinc and tin in wet acid digested foods by flame atomic absorption spectrometry (FAAS) after preconcentration with ultrasound assisted-cloud point extraction (UA-CPE). The preconcentration procedure is making use of 2-(3,4-dihydroxyphenyl)-3,5,7-trihydroxy-4H-chromen-4-one (Quercetin) as the chelating agent, the cationic surfactant cetyltrimethylammonium bromide (CTAB) as the counter ion, the non-ionic surfactant polyoxyethylenesorbitan monolaurate (Tween 20) as the extracting agent, and acidic methanol as the diluting agent. The significant analytical parameters were optimized, and the selected values were a pH of 4.0, a chelating agent concentration of 8.5 μmol L−1, cationic and nonionic surfactant concentrations of 30 μmol L−1 and 0.5% w/v, a sample volume of 10 mL, an equilibrium temperature of 60 °C, an incubation time of 15 min and a diluting agent amount of 1.25 mL. Under optimum conditions, the detection limits for manganese, zinc and tin were 0.34, 0.15 and 0.7 μg L−1 with sensitivity enhancement factors of 116, 175 and 153, respectively. The precision was evaluated as relative standard deviations (RSDs%) for solution containing 15 μg L−1 of Mn(II), 40 μg L−1 of Zn(II), and 20 μg L−1 of Sn(II), and was found to be 2.3, 2.0 and 2.5% (n: 5), respectively. The accuracy of the method was evaluated by analysis of standard reference materials (SRMs) and through recovery rates from spiked aqueous samples. The obtained results were statistically in good agreement with the certified values at the 95% confidence limit, in which the recoveries for target analytes varied in the range of 95.6–104.2%. The method was successfully applied to the analysis of manganese, zinc and tin contents of various food samples, which are generally of plant origin, including black and green tea after dry ashing and wet digestion steps.

Graphical abstract: Ultrasound-assisted cloud point extraction of manganese, zinc and tin from digested food samples for their determination by FAAS

Article information

Article type
Paper
Submitted
21 Apr 2016
Accepted
27 Jun 2016
First published
29 Jun 2016

Anal. Methods, 2016,8, 5930-5939

Author version available

Ultrasound-assisted cloud point extraction of manganese, zinc and tin from digested food samples for their determination by FAAS

N. Altunay, R. Gürkan and S. Korkmaz, Anal. Methods, 2016, 8, 5930 DOI: 10.1039/C6AY01186A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements