Jump to main content
Jump to site search
PLANNED MAINTENANCE Close the message box

Scheduled maintenance work on Wednesday 22nd May 2019 from 11:00 AM to 1:00 PM (GMT).

During this time our website performance may be temporarily affected. We apologise for any inconvenience this might cause and thank you for your patience.


Issue 15, 2016
Previous Article Next Article

Fast sequential determination of manganese and chromium in vegetable oil and biodiesel samples by high-resolution continuum source graphite furnace atomic absorption spectrometry

Author affiliations

Abstract

A fast method for the sequential determination of Mn and Cr in vegetable oil and biodiesel samples using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) was developed. Propan-1-ol, propanone and methyl isobutyl ketone (MIBK) were evaluated as solvents for diluting the samples in different proportions to reduce the viscosity of the samples. MIBK was established as a diluent in a proportion of 40% (v/v). All measurements for the determination of Mn and Cr were performed sequentially using their main atomic lines at 279.4817 and 357.8687 nm, respectively. Two atomization temperatures were used sequentially, 1900 and 2500 °C for Mn and Cr, respectively, due to differences in their volatilities. Mg was employed as a modifier to avoid the loss of Cr and to obtain the best conditions for pyrolysis and atomization. The developed method allowed for the sequential determination of both metals in different types of vegetable oil and biodiesel samples, and it presented limits of quantification of 4.48 and 3.57 ng g−1 for Mn and Cr, respectively. Addition and recovery tests were performed, and the results ranged from 79 to 108% for Mn and from 79 to 115% for Cr. The matrix effect was evaluated by comparing organic and aqueous calibration curves, and the results indicated that external calibration was possible. Vegetable oil and biodiesel samples were analyzed by the proposed method and another procedure using acid digestion, and the results from the two methods were consistent. The proposed method was applied for the determination of Mn and Cr in commercial vegetable oil and biodiesel samples produced from soybean, canola, sunflower and corn.

Graphical abstract: Fast sequential determination of manganese and chromium in vegetable oil and biodiesel samples by high-resolution continuum source graphite furnace atomic absorption spectrometry

Back to tab navigation

Publication details

The article was received on 18 Jan 2016, accepted on 15 Mar 2016 and first published on 15 Mar 2016


Article type: Paper
DOI: 10.1039/C6AY00165C
Anal. Methods, 2016,8, 3249-3254

  •   Request permissions

    Fast sequential determination of manganese and chromium in vegetable oil and biodiesel samples by high-resolution continuum source graphite furnace atomic absorption spectrometry

    J. S. Almeida, G. C. Brandão, G. L. dos Santos and L. S. G. Teixeira, Anal. Methods, 2016, 8, 3249
    DOI: 10.1039/C6AY00165C

Search articles by author

Spotlight

Advertisements