Issue 12, 2016

Development of a sensitive liquid–liquid extraction method for the determination of N-butyryl-l-homoserine lactone produced in a submerged membrane bioreactor by gas chromatography mass spectrometry and deuterated anthracene as the internal standard

Abstract

Quorum sensing is defined as the bacterial communication through sending and receiving chemical signals such as N-acyl homoserine lactone (AHL) and oligopeptide for Gram negative bacteria and Gram positive bacteria, respectively. This mysterious bacterial interaction regulates a wide range of activities affecting the environment, agriculture, and therefore, humans. In the last century, quorum sensing investigations trying to follow and measure these chemical signals have accelerated. In this study, an analytical method was developed and optimized in order to extract and measure one of the AHLs: N-butyryl-L-homoserine lactone (C4-HSL) by gas chromatography-mass spectrometry (GC-MS). The aim of the study was to develop a method that increases the sensitivity and precision of AHL detection by GC-MS due to the problem in the determination of analytes in wastewater which have a complex matrix. The limits of detection and quantification obtained for C4-HSL were 12.9 ng mL−1 and 43.3 ng mL−1, respectively. The precision of the method was improved upon using deuterated anthracene as the internal standard, which gave a lower relative standard deviation compared to that without the internal standard.

Graphical abstract: Development of a sensitive liquid–liquid extraction method for the determination of N-butyryl-l-homoserine lactone produced in a submerged membrane bioreactor by gas chromatography mass spectrometry and deuterated anthracene as the internal standard

Article information

Article type
Paper
Submitted
31 Jan 2016
Accepted
18 Feb 2016
First published
23 Feb 2016

Anal. Methods, 2016,8, 2660-2665

Development of a sensitive liquid–liquid extraction method for the determination of N-butyryl-L-homoserine lactone produced in a submerged membrane bioreactor by gas chromatography mass spectrometry and deuterated anthracene as the internal standard

N. Bakaraki, D. S. Chormey, S. Bakirdere and G. O. Engin, Anal. Methods, 2016, 8, 2660 DOI: 10.1039/C6AY00317F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements