A highly sensitive and simply operated protease sensor toward point-of-care testing

Author affiliations

Abstract

Protease sensors for point-of-care testing (POCT) require simple operation, a detection period of less than 20 minutes, and a detection limit of less than 1 ng mL−1. However, it is difficult to meet these requirements with protease sensors that are based on proteolytic cleavage. This paper reports a highly reproducible protease sensor that allows the sensitive and simple electrochemical detection of the botulinum neurotoxin type E light chain (BoNT/E-LC), which is obtained using (i) low nonspecific adsorption, (ii) high signal-to-background ratio, and (iii) one-step solution treatment. The BoNT/E-LC detection is based on two-step proteolytic cleavage using BoNT/E-LC (endopeptidase) and L-leucine-aminopeptidase (LAP, exopeptidase). Indium-tin oxide (ITO) electrodes are modified partially with reduced graphene oxide (rGO) to increase their electrocatalytic activities. Avidin is then adsorbed on the electrodes to minimize the nonspecific adsorption of proteases. Low nonspecific adsorption allows a highly reproducible sensor response. Electrochemical–chemical (EC) redox cycling involving p-aminophenol (AP) and dithiothreitol (DTT) is performed to obtain a high signal-to-background ratio. After adding a C-terminally AP-labeled oligopeptide, DTT, and LAP simultaneously to a sample solution, no further treatment of the solution is necessary during detection. The detection limits of BoNT/E-LC in phosphate-buffered saline are 0.1 ng mL−1 for an incubation period of 15 min and 5 fg mL−1 for an incubation period of 4 h. The detection limit in commercial bottled water is 1 ng mL−1 for an incubation period of 15 min. The developed sensor is selective to BoNT/E-LC among the four types of BoNTs tested. These results indicate that the protease sensor meets the requirements for POCT.

Graphical abstract: A highly sensitive and simply operated protease sensor toward point-of-care testing

Supplementary files

Article information


Submitted
31 Jan 2016
Accepted
07 Mar 2016
First published
16 Mar 2016

Analyst, 2016,141, 2481-2486
Article type
Paper

A highly sensitive and simply operated protease sensor toward point-of-care testing

S. Park, Y. M. Shin, J. Seo, J. Song and H. Yang, Analyst, 2016, 141, 2481 DOI: 10.1039/C6AN00251J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.


Social activity

Search articles by author

Spotlight

Advertisements