Issue 5, 2015

A comparative study of graphene–hydrogel hybrid bionanocomposites for biosensing

Abstract

Hydrogels have become increasingly popular as immobilization materials for cells, enzymes and proteins for biosensing applications. Enzymatic biosensors that utilize hydrogel as an encapsulant have shown improvements over other immobilization techniques such as cross linking and covalent bonding. However, to date there are no studies which directly compare multiple hydrogel–graphene nanocomposites using the same enzyme and test conditions. This study compares the performance of four different hydrogels used as protein encapsulants in a mediator-free biosensor based on graphene–nanometal–enzyme composites. Alcohol oxidase (AOx) was encapsulated in chitosan poly-N-isopropylacrylamide (PNIPAAM), silk fibroin or cellulose nanocrystals (CNC) hydrogels, and then spin coated onto a nanoplatinum–graphene modified electrode. The transduction mechanism for the biosensor was based on AOx-catalyzed oxidation of methanol to produce hydrogen peroxide. To isolate the effect(s) of stimulus response on biosensor behavior, all experiments were conducted at 25 °C and pH 7.10. Electroactive surface area (ESA), electrochemical impedance spectroscopy (EIS), sensitivity to methanol, response time, limit of detection, and shelf life were measured for each bionanocomposite. Chitosan and PNIPAAM had the highest sensitivity (0.46 ± 0.2 and 0.3 ± 0.1 μA mM−1, respectively) and electroactive surface area (0.2 ± 0.06 and 0.2 ± 0.02 cm2, respectively), as well as the fastest response time (4.3 ± 0.8 and 4.8 ± 1.1 s, respectively). Silk and CNC demonstrated lower sensitivity (0.09 ± 0.02 and 0.15 ± 0.03 μA mM−1, respectively), lower electroactive surface area (0.12 ± 0.02 and 0.09 ± 0.03 cm2, respectively), and longer response time (8.9 ± 2.1 and 6.3 ± 0.8 s, respectively). The high porosity of chitosan, PNIPAAM, and silk gels led to excellent transport, which was significantly better than CNC bionanocomposites. Electrochemical performance of CNC bionanocomposites were relatively poor, which may be linked to poor gel stability. The differences between the Chitosan/PNIPAAM group and the Silk/CNC group were statistically significant (p < 0.05) based on ANOVA. Each of these composites was within the range of other published devices in the literature, while some attributes were significantly improved (namely response time and shelf life). The main advantages of these hydrogel composites over other devices is that only one enzyme is required, all materials are non-toxic, the sensor does not require mediators/cofactors, and the shelf life and response time are significantly improved over other devices.

Graphical abstract: A comparative study of graphene–hydrogel hybrid bionanocomposites for biosensing

Associated articles

Supplementary files

Article information

Article type
Paper
Submitted
03 Oct 2014
Accepted
19 Dec 2014
First published
24 Dec 2014

Analyst, 2015,140, 1466-1476

A comparative study of graphene–hydrogel hybrid bionanocomposites for biosensing

S. L. Burrs, D. C. Vanegas, M. Bhargava, N. Mechulan, P. Hendershot, H. Yamaguchi, C. Gomes and E. S. McLamore, Analyst, 2015, 140, 1466 DOI: 10.1039/C4AN01788A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements