Dynamic formation of a microchannel array enabling kinesin-driven microtubule transport between separate compartments on a chip

Author affiliations

Abstract

Microtubules driven by kinesin motors have been utilised as “molecular shuttles” in microfluidic environments with potential applications in autonomous nanoscale manipulations such as capturing, separating, and/or concentrating biomolecules. However, the conventional flow cell-based assay has difficulty in separating bound target molecules from free ones even with buffer flushing because molecular manipulations by molecular shuttles take place on a glass surface and molecular binding occurs stochastically; this makes it difficult to determine whether molecules are carried by molecular shuttles or by diffusion. To address this issue, we developed a microtubule-based transport system between two compartments connected by a single-micrometre-scale channel array that forms dynamically via pneumatic actuation of a polydimethylsiloxane membrane. The device comprises three layers—a control channel layer (top), a microfluidic channel layer (middle), and a channel array layer (bottom)—that enable selective injection of assay solutions into a target compartment and dynamic formation of the microchannel array. The pneumatic channel also serves as a nitrogen supply path to the assay area, which reduces photobleaching of fluorescently labelled microtubules and deactivation of kinesin by oxygen radicals. The channel array suppresses cross-contamination of molecules caused by diffusion or pressure-driven flow between compartments, facilitating unidirectional transport of molecular shuttles from one compartment to another. The method demonstrates, for the first time, efficient and unidirectional microtubule transport by eliminating diffusion of target molecules on a chip and thus may constitute one of the key aspects of motor-driven nanosystems.

Graphical abstract: Dynamic formation of a microchannel array enabling kinesin-driven microtubule transport between separate compartments on a chip

Back to tab navigation

Supplementary files

Publication details

The article was received on 05 Feb 2015, accepted on 13 Mar 2015 and first published on 13 Mar 2015


Article type: Paper
DOI: 10.1039/C5LC00148J
Author version
available:
Download author version (PDF)
Lab Chip, 2015,15, 2055-2063
  • Open access: Creative Commons BY license
  •   Request permissions

    Dynamic formation of a microchannel array enabling kinesin-driven microtubule transport between separate compartments on a chip

    K. Fujimoto, M. Nagai, H. Shintaku, H. Kotera and R. Yokokawa, Lab Chip, 2015, 15, 2055
    DOI: 10.1039/C5LC00148J

    This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. Material from this article can be used in other publications provided that the correct acknowledgement is given with the reproduced material.

    Reproduced material should be attributed as follows:

    • For reproduction of material from NJC:
      [Original citation] - Published by The Royal Society of Chemistry (RSC) on behalf of the Centre National de la Recherche Scientifique (CNRS) and the RSC.
    • For reproduction of material from PCCP:
      [Original citation] - Published by the PCCP Owner Societies.
    • For reproduction of material from PPS:
      [Original citation] - Published by The Royal Society of Chemistry (RSC) on behalf of the European Society for Photobiology, the European Photochemistry Association, and RSC.
    • For reproduction of material from all other RSC journals:
      [Original citation] - Published by The Royal Society of Chemistry.

    Information about reproducing material from RSC articles with different licences is available on our Permission Requests page.

Search articles by author

Spotlight

Advertisements