Jump to main content
Jump to site search

Issue 4, 2015
Previous Article Next Article

Malaria detection using inertial microfluidics

Author affiliations

Abstract

Diagnosis of malaria at the early stage of infection is challenging due to the difficulty in detecting low abundance parasites from blood. Molecular methods such as real-time polymerase chain reaction (qPCR) can be especially useful for detecting low parasitemia levels due to their high sensitivity and their ability to recognize different malarial species and strains. Unfortunately, the accuracy of qPCR-based malaria detection can be compromised by many factors, including the limited specificity of primers, presence of PCR inhibitors in blood serum and DNA contamination from nucleated blood cells. Here, we use a label-free, shear-modulated inertial microfluidic system to enrich malaria parasites from blood so as to facilitate a more reliable and specific PCR-based malaria detection. This technique capitalizes on cell focusing behaviors in high aspect ratio microchannels coupled with pinched flow dynamics to isolate ring-stage malaria parasites from lysed blood containing white blood cells (WBCs). In this high aspect ratio (ratio of the channel height to the width) platform, the high shear rate along the channel width causes the dispersed WBCs at the inlet to migrate and align into two streams near the channel sidewalls while the malaria parasites remain unfocused. Sensitive detection of parasites at spiked densities ranging from 103 to 104Plasmodium falciparum parasites per mL (~2–10 per μL) has been demonstrated; they have also been quantified in whole blood using qPCR. This is approximately 100-fold more sensitive than the gold standard conventional microscopy analysis of thick blood smears. The simplicity of this device makes it ideal for integration with an automatic system for ultra-fast and accurate detection despite low levels of parasitemia. It can also help in malaria screening and elimination efforts.

Graphical abstract: Malaria detection using inertial microfluidics

Back to tab navigation

Supplementary files

Publication details

The article was received on 09 Sep 2014, accepted on 02 Dec 2014 and first published on 05 Dec 2014


Article type: Paper
DOI: 10.1039/C4LC01058B
Author version
available:
Download author version (PDF)
Lab Chip, 2015,15, 1101-1109

  •   Request permissions

    Malaria detection using inertial microfluidics

    M. E. Warkiani, A. K. P. Tay, B. L. Khoo, X. Xiaofeng, J. Han and C. T. Lim, Lab Chip, 2015, 15, 1101
    DOI: 10.1039/C4LC01058B

Search articles by author

Spotlight

Advertisements