Jump to main content
Jump to site search
PLANNED MAINTENANCE Close the message box

Scheduled maintenance work on Wednesday 27th March 2019 from 11:00 AM to 1:00 PM (GMT).

During this time our website performance may be temporarily affected. We apologise for any inconvenience this might cause and thank you for your patience.


Issue 13, 2014
Previous Article Next Article

A flow cytometry-based submicron-sized bacterial detection system using a movable virtual wall

Author affiliations

Abstract

Detection of pathogenic bacteria requires a sensitive, accurate, rapid, and portable device. Given that lethal microbes are of various sizes, bacterial sensors based on DC (direct current) impedance on chips should be equipped with channels with commensurate cross sections. When it comes to counting and interrogation of individual bacteria on a microfluidic chip, very narrow channels are required, which are neither easy nor cost-effective to fabricate. Here, we report a flow cytometry-based submicron-sized bacterial detection system using a movable virtual wall made of a non-conducting fluid. We show that the effective dimension of a microfluidic channel can be adjusted by varying the respective flow rates of a sample solution as well as the liquid wall therein. Using such a virtual wall, we have successfully controlled the channel width and detected submicron-sized Francisella tularensis, a lethal, tularemia-causing bacterium. Since the system is capable of monitoring changes in DC impedance and fluorescence simultaneously, we were also able to discriminate between different types of bacterial mixtures containing F. tularensis and E. coli BL21 that have different gamuts of size distributions. The proposed flow cytometry-based system represents a promising way to detect bacteria including, but not limited to, submicron-sized pathogenic microbes.

Graphical abstract: A flow cytometry-based submicron-sized bacterial detection system using a movable virtual wall

Back to tab navigation

Supplementary files

Publication details

The article was received on 25 Feb 2014, accepted on 10 Apr 2014 and first published on 10 Apr 2014


Article type: Paper
DOI: 10.1039/C4LC00238E
Citation: Lab Chip, 2014,14, 2327-2333

  •   Request permissions

    A flow cytometry-based submicron-sized bacterial detection system using a movable virtual wall

    H. Choi, C. S. Jeon, I. Hwang, J. Ko, S. Lee, J. Choo, J. Boo, H. C. Kim and T. D. Chung, Lab Chip, 2014, 14, 2327