Jump to main content
Jump to site search

Issue 9, 2014
Previous Article Next Article

Highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry

Author affiliations

Abstract

To realise highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry (ICP-MS), we developed a modified high efficiency cell introduction system (HECIS), consisting of a large-bore high performance concentric nebulizer (LB-HPCN) with a centre capillary tube of 150 μm inner diameter and a custom-made small-volume (15 cm3) on-axis spray chamber that uses a sheath gas flow near the chamber exit to suppress cell deposition. We also assembled an external ion pulse counting unit to directly read the ion pulse current from the electron multiplier of the ICP-MS via a function generator with no dead time, in order to obtain data with sufficiently high time resolution (i.e., 0.05–1 ms). As compared to a conventional ICP-MS working at its minimum integration time (10 ms), this assembly led to more than ca. 13-fold higher signal-to-background ratios for 31P, and made higher throughput of cells to the plasma more feasible. By using the modified HECIS and the external ion pulse counting unit for determination of the cell introduction efficiencies of different-sized unicellular microbes, including yeast (Saccharomyces cerevisiae), cyanobacterium (Synechocystis sp. PCC 6803), red algae (Cyanidioschyzon merolae 10D and Galdieria sulphuraria), and green alga (Chlamydomonas reinhardtii CC-125), it was revealed that their cell introduction efficiencies ranged from 86% (for C. reinhardtii CC-125 with a mean cell diameter of 6.4 μm) to ca. 100% (for other microbes with mean cell diameters of 2.0–3.0 μm), implying that by use of the ICP-MS system, the cell introduction efficiencies are able to reach approximately 100% and tend to decrease with increasing cell sizes (at least more than 3.1 μm in mean diameter). A wide range of biologically important elements, such as C, Mg, Al, P, S, K, Ca, Cr, Mn, Fe, and Zn, were tested for reasonable detection using the ICP-MS system. Results likely corresponding to separate cell events were obtained for some elements present in each microbe.

Graphical abstract: Highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry

Back to tab navigation

Supplementary files

Publication details

The article was received on 29 Jan 2014, accepted on 20 May 2014 and first published on 20 May 2014


Article type: Paper
DOI: 10.1039/C4JA00040D
Author version
available:
Download author version (PDF)
Citation: J. Anal. At. Spectrom., 2014,29, 1598-1606
  •   Request permissions

    Highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry

    S. Miyashita, A. S. Groombridge, S. Fujii, A. Minoda, A. Takatsu, A. Hioki, K. Chiba and K. Inagaki, J. Anal. At. Spectrom., 2014, 29, 1598
    DOI: 10.1039/C4JA00040D

Search articles by author

Spotlight

Advertisements