Issue 3, 2014

Precise tellurium isotope analysis by negative thermal ionization mass spectrometry (N-TIMS)

Abstract

We present a new method for precise isotope analysis of Te by thermal ionization mass spectrometry in negative ion mode (N-TIMS) along with an improved technique for chemical separation of Te from geochemical samples. In the chemical separation, Te was purified by a three-step column chemistry method employing an anion exchange resin and an extraction chromatographic resin, yielding 98% recovery. To achieve strong Te beam intensity in N-TIMS, we evaluated the optimum analytical conditions with respect to the filament material, ionization activator, and filament heating protocol. The reproducibilities of Te isotope ratios obtained by static multicollection using Faraday cups were 0.9%, 0.04%, 0.06%, 0.01%, 0.005%, and 0.008% for 120Te/128Te, 122Te/128Te, 123Te/128Te, 125Te/128Te, 126Te/128Te, and 130Te/128Te, respectively. This result is comparable to those of previous MC-ICP-MS studies. The reproducibilities of Te isotopes obtained by SEM jumping measurements were approximately ten times worse than those obtained by Faraday cup runs, excluding the 120Te/128Te ratio for which the reproducibility was comparable to that obtained by Faraday cup runs due to the extremely low abundance of 120Te. To further improve the analytical precision, the 126Te/128Te ratio was determined by multidynamic collection for the study of 126Sn–126Te chronology. The 2s of the 126Te/128Te ratio of the multidynamic collection was 1.6 times better than that obtained by static measurements. Finally, the accuracy of our method was confirmed by the analysis of two carbonaceous chondrites and one terrestrial standard rock, which was consistent with previously reported values.

Graphical abstract: Precise tellurium isotope analysis by negative thermal ionization mass spectrometry (N-TIMS)

Article information

Article type
Paper
Submitted
27 Sep 2013
Accepted
29 Nov 2013
First published
10 Jan 2014

J. Anal. At. Spectrom., 2014,29, 520-528

Author version available

Precise tellurium isotope analysis by negative thermal ionization mass spectrometry (N-TIMS)

Y. Fukami and T. Yokoyama, J. Anal. At. Spectrom., 2014, 29, 520 DOI: 10.1039/C3JA50317H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements