Issue 23, 2014

An accurate and transferable protocol for reproducible quantification of organic pollutants in human serum using direct isotope dilution mass spectrometry

Abstract

A robust method has been developed for easy transfer between analytical laboratories to obtain highly accurate and reproducible quantification of persistent organic pollutants (POPs) in micro-volumes of serum. This method is suited for analysts researching the impact of environmental exposure on human health. When performed by highly trained analysts, existing methods can produce high quality data; however, complex sample preparation steps often cannot be consistently replicated by laboratories, leading to variance in extraction recovery and quantitation. By combining stir-bar sorptive extraction (SBSE) with direct isotope dilution (D-ID) mass spectrometry quantification, a new analytical method was developed. The D-ID quantification significantly improved accuracy, corrected sample-to-sample irreproducibility, and reduced sample preparation time. Independent production of statistically identical data then confirmed transfer of the validated operating protocol to an off-site laboratory with different instrument models. SBSE performance was compared with industry-accepted extraction techniques. D-ID quantification was compared with peer-reviewed relative isotopic response factor (RF) quantification methods. Holding other variables constant, D-ID improved accuracy by 250% and precision by 300% compared with RF; SBSE improved accuracy by 37% compared to industry-accepted extraction methods. Limits of quantification of the analytes ranged from 60 pg g−1 to 1 μg g−1. Protocol transfer exhibited <7% mean between-laboratory error and <2% mean within-laboratory RSD. These results indicate that a transferable method has been developed for academic, government, commercial, and clinical laboratories seeking to maximize throughput and improve quantitative validity. This validated method was applied in a recent clinical study to assess non-communicable disease in children in Pennsylvania, USA.

Graphical abstract: An accurate and transferable protocol for reproducible quantification of organic pollutants in human serum using direct isotope dilution mass spectrometry

Article information

Article type
Paper
Submitted
11 May 2014
Accepted
05 Aug 2014
First published
05 Aug 2014

Analyst, 2014,139, 6223-6231

Author version available

An accurate and transferable protocol for reproducible quantification of organic pollutants in human serum using direct isotope dilution mass spectrometry

A. J. Boggess, G. M. M. Rahman, M. Pamukcu, S. Faber and H. M. S. Kingston, Analyst, 2014, 139, 6223 DOI: 10.1039/C4AN00851K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements